. 1969 Feb 1;1(5639):286–289. doi: 10.1136/bmj.1.5639.286

Measurement of Digoxin in Plasma and its use in Diagnosis of Digoxin Intoxication

D G Grahame-Smith, M S Everest
PMCID: PMC1982164  PMID: 5762647

Abstract

A method for measuring the plasma-digoxin concentration uses the measurement of its inhibitory effect on 86Rb uptake by human red cells in vitro. Patients receiving digoxin in whom there was no clinical evidence of digoxin intoxication had plasma digoxin concentrations ranging from 0·8 to 4·5 mμg./ml. Patients presenting with convincing clinical evidence of digoxin intoxication had plasma digoxin concentrations ranging from 4 to greater than 8 mμg./ml. It is suggested that the plasma digoxin concentration may be used as an aid in the diagnosis of digoxin intoxication.

Full text

PDF
286

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. GLYNN I. M. The action of cardiac glycosides on sodium and potassium movements in human red cells. J Physiol. 1957 Apr 3;136(1):148–173. doi: 10.1113/jphysiol.1957.sp005749. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. LOVE W. D., BURCH G. E. A comparison of potassium 42, rubidium 86, and cesium 134 as tracers of potassium in the study of cation metabolism of human erythrocytes in vitro. J Lab Clin Med. 1953 Mar;41(3):351–362. [PubMed] [Google Scholar]
  3. LOWENSTEIN J. M. A METHOD FOR MEASURING PLASMA LEVELS OF DIGITALIS GLYCOSIDES. Circulation. 1965 Feb;31:228–233. doi: 10.1161/01.cir.31.2.228. [DOI] [PubMed] [Google Scholar]
  4. Lukas D. A., Peterson R. E. Double isotope dilution derivative assay of digitoxin in plasma, urine, and stool of patients maintained on the drug. J Clin Invest. 1966 May;45(5):782–795. doi: 10.1172/JCI105393. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Lyon A. F., DeGraff A. C. Reappraisal of digitalis. V. Evaluation of criteria for determining effect of digitalis in man. Am Heart J. 1967 Jan;73(1):134–136. doi: 10.1016/0002-8703(67)90319-5. [DOI] [PubMed] [Google Scholar]
  6. Oliver G. C., Jr, Parker B. M., Brasfield D. L., Parker C. W. The measurement of digitoxin in human serum by radioimmunoassay. J Clin Invest. 1968 May;47(5):1035–1042. doi: 10.1172/JCI105793. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Medical Journal are provided here courtesy of BMJ Publishing Group

RESOURCES