Skip to main content
Applied and Environmental Microbiology logoLink to Applied and Environmental Microbiology
. 1989 Dec;55(12):3091–3094. doi: 10.1128/aem.55.12.3091-3094.1989

Comparison of membrane filtration and Autoanalysis Colilert presence-absence techniques for analysis of total coliforms and Escherichia coli in drinking water samples.

C M Lewis 1, J L Mak 1
PMCID: PMC203228  PMID: 2694959

Abstract

Over a 4-month period, 950 samples of treated drinking water were analyzed for total coliforms (TC) and Escherichia coli by both membrane filtration (MF) and Autoanalysis Colilert presence-absence (AC) techniques. The two tests agreed 97% of the time on the basis of presumptive TC results and 98.5% of the time on the basis of verified TC results. Samples which produced disagreement between the two tests were most often TC positive by MF and TC negative by AC. E. coli was recovered four times: twice by MF only, and twice by AC only but without the diagnostic fluorescence reaction. In two samples, E. coli could not be isolated from fluorescence-positive AC tests. On the basis of these results, the AC test was implemented as the routine analytical procedure for TC but not for E. coli.

Full text

PDF
3091

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Caplenas N. R., Kanarek M. S. Thermotolerant non-fecal source Klebsiella pneumoniae: validity of the fecal coliform test in recreational waters. Am J Public Health. 1984 Nov;74(11):1273–1275. doi: 10.2105/ajph.74.11.1273. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Chang G. W., Brill J., Lum R. Proportion of beta-D-glucuronidase-negative Escherichia coli in human fecal samples. Appl Environ Microbiol. 1989 Feb;55(2):335–339. doi: 10.1128/aem.55.2.335-339.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Christian R. R., Pipes W. O. Frequency distribution of coliforms in water distribution systems. Appl Environ Microbiol. 1983 Feb;45(2):603–609. doi: 10.1128/aem.45.2.603-609.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Edberg S. C., Allen M. J., Smith D. B. National field evaluation of a defined substrate method for the simultaneous enumeration of total coliforms and Escherichia coli from drinking water: comparison with the standard multiple tube fermentation method. Appl Environ Microbiol. 1988 Jun;54(6):1595–1601. doi: 10.1128/aem.54.6.1595-1601.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Tse K. M., Lewis C. M. Membrane filter staining method: bacterial plate counts in 24 H. Appl Environ Microbiol. 1984 Aug;48(2):433–434. doi: 10.1128/aem.48.2.433-434.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Applied and Environmental Microbiology are provided here courtesy of American Society for Microbiology (ASM)