Abstract
To ascertain the feasibility of heat inactivation as an eradication method applicable to all members of the family Legionellaceae, we tested the heat resistance of 75 isolates which represented 19 members of this family of organisms. The ranges of thermal death times at 60, 70, and 80 degrees C were 1.3 to 10.6, 0.7 to 2.6, and 0.3 to 0.7 min, respectively. These data suggest that the method of heat eradication will be effective against all members of the family Legionellaceae.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Best M., Yu V. L., Stout J., Goetz A., Muder R. R., Taylor F. Legionellaceae in the hospital water-supply. Epidemiological link with disease and evaluation of a method for control of nosocomial legionnaires' disease and Pittsburgh pneumonia. Lancet. 1983 Aug 6;2(8345):307–310. doi: 10.1016/s0140-6736(83)90290-8. [DOI] [PubMed] [Google Scholar]
- Dennis P. J., Green D., Jones B. P. A note on the temperature tolerance of Legionella. J Appl Bacteriol. 1984 Apr;56(2):349–350. doi: 10.1111/j.1365-2672.1984.tb01359.x. [DOI] [PubMed] [Google Scholar]
- Edelstein P. H. Improved semiselective medium for isolation of Legionella pneumophila from contaminated clinical and environmental specimens. J Clin Microbiol. 1981 Sep;14(3):298–303. doi: 10.1128/jcm.14.3.298-303.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Feeley J. C., Gibson R. J., Gorman G. W., Langford N. C., Rasheed J. K., Mackel D. C., Baine W. B. Charcoal-yeast extract agar: primary isolation medium for Legionella pneumophila. J Clin Microbiol. 1979 Oct;10(4):437–441. doi: 10.1128/jcm.10.4.437-441.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fisher-Hoch S. P., Bartlett C. L., Tobin J. O., Gillett M. B., Nelson A. M., Pritchard J. E., Smith M. G., Swann R. A., Talbot J. M., Thomas J. A. Investigation and control of an outbreaks of legionnaires' disease in a district general hospital. Lancet. 1981 Apr 25;1(8226):932–936. doi: 10.1016/s0140-6736(81)91626-3. [DOI] [PubMed] [Google Scholar]
- Gilchrist J. E., Campbell J. E., Donnelly C. B., Peeler J. T., Delaney J. M. Spiral plate method for bacterial determination. Appl Microbiol. 1973 Feb;25(2):244–252. doi: 10.1128/am.25.2.244-252.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hedges A. J., Shannon R., Hobbs R. P. Comparison of the precision obtained in counting viable bacteria by the spiral plate maker, the droplette and the Miles & Misra methods. J Appl Bacteriol. 1978 Aug;45(1):57–65. doi: 10.1111/j.1365-2672.1978.tb04198.x. [DOI] [PubMed] [Google Scholar]
- Helms C. M., Massanari R. M., Zeitler R., Streed S., Gilchrist M. J., Hall N., Hausler W. J., Jr, Sywassink J., Johnson W., Wintermeyer L. Legionnaires' disease associated with a hospital water system: a cluster of 24 nosocomial cases. Ann Intern Med. 1983 Aug;99(2):172–178. doi: 10.7326/0003-4819-99-2-172. [DOI] [PubMed] [Google Scholar]
- Müller H. E. Die Thermostabilität von Legionella pneumophila. Zentralbl Bakteriol Mikrobiol Hyg B. 1981;172(6):524–527. [PubMed] [Google Scholar]
- Pasculle A. W., Feeley J. C., Gibson R. J., Cordes L. G., Myerowitz R. L., Patton C. M., Gorman G. W., Carmack C. L., Ezzell J. W., Dowling J. N. Pittsburgh pneumonia agent: direct isolation from human lung tissue. J Infect Dis. 1980 Jun;141(6):727–732. doi: 10.1093/infdis/141.6.727. [DOI] [PubMed] [Google Scholar]
- Plouffe J. F., Webster L. R., Hackman B. Relationship between colonization of hospital building with Legionella pneumophila and hot water temperatures. Appl Environ Microbiol. 1983 Sep;46(3):769–770. doi: 10.1128/aem.46.3.769-770.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stout J. E., Yu V. L., Best M. G. Ecology of Legionella pneumophila within water distribution systems. Appl Environ Microbiol. 1985 Jan;49(1):221–228. doi: 10.1128/aem.49.1.221-228.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wadowsky R. M., Yee R. B., Mezmar L., Wing E. J., Dowling J. N. Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures. Appl Environ Microbiol. 1982 May;43(5):1104–1110. doi: 10.1128/aem.43.5.1104-1110.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]