A Simple Technique for Templating of Mesh for Acetabular Reconstruction

C Shanmugam 1, H Wynn Jones 1, MJL Porteous 1
PMCID: PMC2048607  PMID: 18172940

BACKGROUND

Revision hip arthroplasty often requires the reconstruction of large acetabular defects. One technique by which this can be achieved is to use mesh and impaction bone grafting. The mesh is cut using shears and has to be repeatedly inserted and removed until the desired shape is achieved. The trimmed mesh is difficult to handle with sharp edges. Multiple glove punctures are common, with potential for a sharps injury to the surgeon, and bacterial contamination of the mesh. The sharp edges also catch awkwardly on the surrounding soft tissues and skin during insertion and removal, causing damage. We suggest a templating technique, which minimises these problems.

Figure 1.

Figure 1

The use of an intra-operative template (disposable tray) to fash-ion an acetabular reconstruction mesh.

Figure 2.

Figure 2

Template over the mesh.

Figure 3.

Figure 3

Mesh was fashioned using the template.

Figure 4.

Figure 4

Mesh comfortably seated in the acetabulum without any soft tissue damage.

TECHNIQUE

An estimate of the required size of mesh is made by measuring the acetabular defect using a flexible ruler. A provisional template is then cut from a flat sheet of moldable plastic. We have found a disposable sterile instrument tray on which the mesh cutter is packaged on by our local sterile services department to be ideal (Disposable instrument tray, DeRoyal). The template is then offered up to the acetabulum and trimmed until the desired shape is achieved. The metal mesh can then be easily cut to the correct shape using the template, and only has to be handled once during insertion.

DISCUSSION

The plastic template is easy and safe to handle when manoeuvring it in and out of the wound. A mesh of the appropriate shape is reliably produced without the hazards of repeated handling. No additional cost is added to the procedure. The use of a template minimises the risk of inadvertently wasting an expensive mesh by accidentally cutting it too small. We now routinely use this technique in acetabular reconstructions requiring mesh.