Abstract
Background
Propagation of simulated action potentials (APs) was previously studied in short single chains and in two-dimensional sheets of myocardial cells [1-3]. The present study was undertaken to examine propagation in a long single chain of cells of various lengths, and with varying numbers of gap-junction (g-j) channels, and to compare propagation velocity with the cable properties such as the length constant (λ).
Methods and Results
Simulations were carried out using the PSpice program as previously described. When the electric field (EF) mechanism was dominant (0, 1, and 10 gj-channels), the longer the chain length, the faster the overall velocity (θov). There seems to be no simple explanation for this phenomenon. In contrast, when the local-circuit current mechanism was dominant (100 gj-channels or more), θov was slightly slowed with lengthening of the chain. Increasing the number of gj-channels produced an increase in θov and caused the firing order to become more uniform. The end-effect was more pronounced at longer chain lengths and at greater number of gj-channels.
When there were no or only few gj-channels (namely, 0, 10, or 30), the voltage change (ΔVm) in the two contiguous cells (#50 & #52) to the cell injected with current (#51) was nearly zero, i.e., there was a sharp discontinuity in voltage between the adjacent cells. When there were many gj-channels (e.g., 300, 1000, 3000), there was an exponential decay of voltage on either side of the injected cell, with the length constant (λ) increasing at higher numbers of gj-channels. The effect of increasing the number of gj-channels on increasing λ was relatively small compared to the larger effect on θov. θov became very non-physiological at 300 gj-channels or higher.
Conclusion
Thus, when there were only 0, 1, or 10 gj-channels, θov increased with increase in chain length, whereas at 100 gj-channels or higher, θov did not increase with chain length. When there were only 0, 10, or 30 gj-channels, there was a very sharp decrease in ΔVm in the two contiguous cells on either side of the injected cell, whereas at 300, 1000, or 3000 gj-channels, the voltage decay was exponential along the length of the chain. The effect of increasing the number of gj-channels on spread of current was relatively small compared to the large effect on θov.
Background
Successful transmission of excitation from one myocardial cell to the next contiguous cell can occur without the necessity of gj-channels between the cells. This has been demonstrated to be possible in theoretical and modeling studies by Sperelakis and colleagues [1-5], and has been confirmed by other laboratories [6-8]. As was stated in the 1977 paper of Sperelakis and Mann [4], for the EF mechanism to work successfully, the junctional membrane must be more excitable than the contiguous surface sarcolemma. The fact that the junctional membranes (i.e., the intercalated disks) have a higher concentration (density) of fast Na+ channels than the surface sarcolemma should cause them to be more excitable than the surface membrane. In a simulation study of cardiac muscle, Kucera et al. [9] determined how conduction velocity varied with the fraction of fast INa channels located in the junctional membranes. For a 10 nm (100 Å) cleft width and 50 % of the INa channels located in the junctional membranes, they found that conduction still occurred at a velocity of about 20 cm/sec when cell coupling was reduced to 10 % of normal and at about 10 cm/sec when coupling was only 1 % of normal. In biological studies on connexon43 knockout mice, absent in gj-channels in their hearts, propagation velocity was only slowed and not blocked [10-12]. Although the presence of gj-channels is not essential for propagation of excitation in the heart, when hearts do contain gj-channels, propagation velocity is speeded up. The PSpice simulation studies suggest that too many gj-channels (e.g., more than 100 channels per junction) causes the propagation velocity to exceed the physiological range.
In previous studies on simulated myocardial cells, propagation of action potentials (APs) was examined in short chains of cells (e.g., 10 cells long) and in 2-dimensional sheets (e.g., 10 × 10 and 20 × 10), with the number of gj-channels varied from zero to 10,000 [1,4,13,14]. Propagation of excitation occurred at near-physiological speeds even when there were no gj-channels connecting between the longitudinally-oriented cells [1]. The mechanism proposed was the relatively large electric field (EF) that develops in the narrow junctional clefts when the prejunctional membrane fires an AP [1,4,13-15]. This EF action is accentuated when the junctional membranes contain fast Na+ channels at a higher density than that in the surface sarcolemma [9,15,16]. Transverse propagation also occurred by the same EF mechanism between adjacent parallel chains that were closely packed [2,3].
The present study was undertaken to examine propagation in long single chains, in which the cells were connected by varying numbers of gj-channels, and to compare the propagation velocity with the measured cable properties, such as the length constant (λ). It was found that the effect of increasing the number of gj-channels on λ was relatively small compared to the large effect on propagation velocity. In addition, the present studies were undertaken to provide confirmation of the parameter values used in the model, as for example, the values of the input resistance and the length constant.
Methods
Compared to other models, such as the mathematical model, a simulation study of cardiac muscle using PSpice provides the ability to change the electrical equivalence of physiological parameters. A simulation study by PSpice can be made as accurate as using the mathematical model. Additionally, PSpice provides the ability to vary the parameters at a discrete point in a chain of cardiac cells, whereas in the mathematical model this requires an extensive reconstruction of the circuit. Another important advantage of PSpice is its portability. That is, the model can be easily transferred from person to person for confirmation and for further studies. For example, we have submitted our model for publication in a website [17] for easy use by other investigators. In addition, we have provided similar information to numerous individuals who have contacted us. Furthermore, several other types of electrophysiological studies have been done recently using PSpice.
The methods used for the PSpice simulations were thoroughly described in previous publications [1-3,18,19]. The essential difference is that the present study used long single chains of 10, 20, 50, and 100 cells. The 100-cell chain is depicted in Figure 1. All parameters used were those used previously, and they are summarized in Table 1. One variable was the number of gj-channels that was inserted between the contiguous cells (0, 1, 10, 30, 50, 70, 100, 300, 1000, or 3000). Each gj-channel was assumed to have a conductance of 100 pS. For the study on propagation velocity, Cell #1 was stimulated with intracellular rectangular depolarizing current pulses (0.1 nA, 0.25 ms).
Table 1.
Parameters | Values |
Cm | 300 fF (30) |
RK | 71 MΩ (710) |
RNa | 710 MΩ (7100) |
EK | -94 mV |
ENa | +60 mV |
Rd | 5000 MΩ |
Cd | 30 pF |
Ror | 1.0 KΩ |
Rol | 1.0 KΩ |
Ri | 500 KΩ |
Rjc | 25 MΩ |
Values for junctional units given in parentheses
Cm = Total cell capacitance
RK = Potassium resistance
RNa = Sodium resistance
EK = Potassium equilibrium potential
ENa = Sodium equilibrium potential
Rd = Resistance in delay circuit for second black-box to bring about AP repolarization
Cd = Capacitance in delay circuit for second black-box
Ror = Radial resistance of external fluid
Rol = Longitudinal resistance of external fluid
Ri = Longitudinal resistance of intracellular fluid
Rjc = Radial resistance of junctional cleft
For study of cable properties, the basic units were rendered inexcitable by removal of their GTABLEs. The GTABLE is PSpice nomenclature for specifying how the conductance (or current) varies with membrane potential during excitation [1]. Intracellular current pulses (Io) were applied to the middle of the 100-cell chain (namely cell #51), and the fall-off of voltage was measured on both sides of the injected cell. The resulting potentials were plotted on linear and logarithmic ordinates (i.e., semilog plot) to measure the λ values. The λ values can also be calculated from the following equation:
where ΔVx is the voltage change at any distance x, ΔV0 is the voltage change at the point of current injection (x = 0), and λ is the length constant (in cm). Equation #1 may be solved for λ by the following expression:
where 2.303 is the factor for converting natural logs to logs to the base of 10.
The input resistance (Rin) was measured from the slope of the linear ΔVm/Io curve in the injected cell (#51). The polarization resistance (Rp) was measured from the linear ΔVm/Io slopes in the contiguous cells. These V/I curves were linear, on both the depolarizing and hyperpolarizing sides, because rectification was not incorporated into the basic units.
The myocardial cells were assumed to be cylindrical in shape, 150 μm in length and 16 μm in diameter. The cleft width of the cell junctions (intercalated disks) was assumed to be 100 Å, and the radial shunt resistance of the junction to be 25 MΩ (50 MΩ/2) (Table 1).
Results and Discussion
A. Propagation velocity in single chains
1. Variation in number of gj-channels (100-cell chain)
The overall velocity of propagation (θov) increased markedly with an increase in number of gj-channels inserted at the cell junctions. These results are depicted in Figure 2. The number of gj-channels was varied over a very wide range, from 0 (complete EF mechanism for transmission of excitation from cell to cell) to 10,000 (0, 10, 30, 50, 70, 100, 200, 300, 1000, 3000, and 10,000). The records illustrated in Figure 2 are only for 0, 30, 1000, 3000 and 10,000 gj-channels. The propagation velocity became non-physiologically fast when there were 100 or more gj-channels (Fig. 3). "Non-physiologically fast" means that propagation velocity was considerably above values measured in the heart. As can be seen in Figure 3, there was a nearly linear relationship between θov and the number of gj-channels up to 300.
The propagation velocity at zero gj-channels varied from 10.6 cm/sec for a 10-cell chain, to 18.5 cm/sec for a 20-cell chain, to 46.0 cm/sec for a 50-cell chain, and to 95.5 cm/sec for a 100-cell chain (Table 2).
Table 2.
A. 100 cells | |||
No. of gj-channels | θov | Firing order | End-effect |
(cm/s) | (Rating) | (cells affected) | |
0 | *95.5 | C | 10 – 100 |
1 | #92.0 | C | 20 – 100 |
10 | 102 | B | 50 – 100 |
30 | 117 | A- | 90 – 100 |
50 | 120 | A | 90 – 100 |
70 | 139 | A | 90 – 100 |
100 | 169 | A | 90 – 100 |
1000 | 833 | A | 90 – 100 |
B. 50 cells | |||
0 | 46.0 | B | 30 – 50 |
1 | 46.3 | A- | Bunching |
10 | 51.4 | A | Yes (slight) |
100 | 188 | A | Yes |
D. 20 cells | |||
0 | 18.5 | C | No |
1 | 23.1 | A- | Bunching |
10 | 53.6 | A | Yes (slight) |
E. 10 cells | |||
0 | 10.6 | A- | 9 – 10 |
1 | 19.2 | A | 9 – 10 (sl) |
* θov was 91.5 cm/s when Rjc was lowered to 5 MΩ (from std. of 50 MΩ)
# θov was slightly slowed by inserting one gj-channel
2. Variation in length of single chain
The length of the single chain was also varied, and different numbers of gj-channels were inserted. These results are depicted in Figure 4. The length of the chain was varied between 10 and 100 cells. As shown in Figure 4, when the EF mechanism was dominant (0, 1, or 10 gj-channels), propagation velocity increased almost linearly with increase in chain length. We believe that this phenomenon may be caused by an end-effect. When the local-circuit current mechanism was dominant (100 gj-channels or higher), then propagation velocity did not increase with chain length, and, in fact, there was a decrease (Fig. 4).
Our explanation for why θov decreases at longer chain lengths, when there are many gj-channels, is as follows. When there are 100 gj-channels, for example, and the chain length is short (e.g., 10 cells long), then the spread of the stimulation current extends over a greater fractional length of the chain, so those cells are simultaneously brought to threshold. Therefore, regular propagation need occur over only a few cells, so θov is larger. As the chain length is extended, this effect becomes smaller and smaller, so θov decreases.
Table 2 summarizes the propagation velocity data given in this section and section #1 above, and, in addition, summarizes the uniformity of firing and the end-effect that was observed. The end-effect is a phenomenon that is well known in electrical engineering and occurs at the end (or edge) of a long circuit containing repeat units and in cables that have a sharp termination point. We previously showed that end-effects do occur in our PSpice model [20]. As shown in Table 2, propagation velocity at 0, 1, or 10 gj-channels (EF mechanism dominant) was markedly slowed at shorter chain lengths, with values of about 10.6, 18.5, and 46.0 cm/sec for 0 gj-channels. These slower values are more in line with the values of 30–50 cm/sec previously reported for short chains and small 2-dimensional sheets when propagation was by the EF mechanism alone [1-3]. As reported previously, θov (for 0 gj-channels) was critically dependent on the value of Rjc, the radial shunt resistance of the juntional clefts. In the present study, Rjc was held fixed at 25 MΩ (50 MΩ/2).
As shown in Table 2, the firing order in a 100-cell chain became uniform when the number of gj-channels was increased to 30 or more. That is, when the EF mechanism was dominant (0, 1, or 10 gj-channels), the firing order was erratic. We believe that erratic firing was caused by a prominent end-effect. However, at shorter chain lengths, propagation became more uniform at no or few gj-channels. For example, at a chain length of 10 cells (Table 2, D), propagation was quite uniform even at 0 or 1 gj-channel.
There was some parallelism between uniformity of firing and the end-effect. The more disordered the firing, the greater the end-effect. For example, in Table 2A for the 100-cell chain, when the firing order was rated as very good ("A" rating), then the end-effect was confined to the last 10% of the chain (cells 90–100). In contrast, when the firing order was rated as poor ("C" rating), the end-effect was evident over the last 80–90% of the chain. When the chain length was shorter (B-D of Table 2), the end-effect, in general, was less pronounced.
B. Voltage fall-off with distance in a 100-cell chain
1. Length constant (λ) measurements
The decay in voltage as a function of distance along a single-chain of 100 cells was measured with various numbers of gj-channels inserted at the cell junctions (Fig. 5). The current (rectangular pulses) was injected intracellularly near the mid-point of the chain, namely into cell #51, and the transmembrane potential change (ΔVm) measured in the adjoining cells on both sides (Tables 3, 4). The original data traces are illustrated in Figure 5 for only four of the gj-channel numbers: 0, 10, 100, and 1000. Note that for 0 and 10 channels, there was a sharp discontinuity in ΔVm between the injected cell and its immediate neighbors. These results are plotted on a linear ordinate scale in Figure 6, and the actual values are listed in Tables 3, 4. When there were no or only a few gj-channels (0, 10, 30), the ΔVm in the contiguous cells on both sides was very small, being almost zero at 0 gj-channels. That is, there was a very sharp discontinuity in ΔVm between the injected cell and its immediate neighbors (Fig. 6). These results are consistent with what has been reported physiologically [21,22]. In such a situation, the length constant (λ) cannot be measured, being imaginary and less than the length of one cell (<150 μm).
Table 3.
No. of gj-channels | Io (nA) | ΔVo (mV) | ΔVx (mV) Cell number |
||||
50 & 52 | 49 & 53 | 48 & 54 | 47 & 55 | ||||
A | 0 | 10.0 | 293 | 0 | 0 | 0 | 0 |
5.0 | 148 | 0 | 0 | 0 | 0 | ||
1.0 | 29.5 | 0 | 0 | 0 | 0 | ||
0.5 | 14.8 | 0 | 0 | 0 | 0 | ||
B | 1 | 10.0 | 295 | 0 | 0 | 0 | 0 |
5.0 | 147 | 0 | 0 | 0 | 0 | ||
1.0 | 29.5 | 0 | 0 | 0 | 0 | ||
0.5 | 14.6 | 0 | 0 | 0 | 0 | ||
C | 10 | 10.0 | 280 | 8.0 | 0 | 0 | 0 |
5.0 | 140 | 4.0 | 0 | 0 | 0 | ||
1.0 | 28.0 | 0.5 | 0 | 0 | 0 | ||
0.5 | 14.0 | 0.2 | 0 | 0 | 0 | ||
D | 100 | 10.0 | 200 | 40.0 | 3.0 | 0 | 0 |
5.0 | 100 | 20.0 | 3.0 | 0 | 0 | ||
1.0 | 20.0 | 4.0 | 0.5 | 0 | 0 | ||
0.5 | 10.0 | 2.0 | 0.3 | 0 | 0 | ||
E | 300 | 10.0 | 139 | 50.1 | 18.1 | 6.5 | 2.4 |
5.0 | 69.3 | 25.0 | 9.0 | 3.3 | 1.2 | ||
1.0 | 13.9 | 5.0 | 1.8 | 0.7 | 0.2 | ||
0.5 | 6.9 | 2.5 | 0.9 | 0.3 | 0.1 | ||
F | 1000 | 10.0 | 83.0 | 48.0 | 26.0 | 15.0 | 8.0 |
5.0 | 42.0 | 23.0 | 13.0 | 7.0 | 4.0 | ||
1.0 | 8.3 | 4.7 | 2.7 | 1.5 | 0.8 | ||
0.5 | 4.2 | 2.3 | 1.3 | 0.7 | 0.4 | ||
G | 3000 | 10.0 | 51.5 | 36.2 | 25.4 | 17.9 | 12.6 |
5.0 | 25.7 | 18.1 | 12.7 | 9.0 | 6.3 | ||
1.0 | 5.1 | 3.6 | 2.5 | 1.8 | 1.3 | ||
0.5 | 2.6 | 1.8 | 1.3 | 0.9 | 0.6 | ||
H | 10000 | 10.0 | 31.2 | 26.7 | 25.0 | 21.5 | 17.2 |
5.0 | 15.6 | 13.3 | 12.5 | 10.8 | 10.0 | ||
1.0 | 3.2 | 2.7 | 2.5 | 2.2 | 2.0 | ||
0.5 | 1.6 | 1.3 | 1.3 | 1.1 | 1.0 |
Current was injected into cell #51 (middle of chain)
Table 4.
ΔVm(mV) | |||||||
Cell Number | Number of gj-channels | ||||||
0 | 10 | 30 | 100 | 300 | 1000 | 3000 | |
47 | 0 | 0 | 0 | 0 | 2.3 | 8.1 | 12.8 |
48 | 0 | 0 | 0 | 0 | 6.6 | 14.5 | 17.6 |
49 | 0 | 0 | 0 | 7.4 | 17.8 | 26.1 | 25.9 |
50 | 0 | 8 | 19.4 | 38.3 | 50.4 | 46.8 | 36.9 |
51 | 298 | 280 | 252 | 200 | 138 (50.9) | 83.0 (30.5) | 50.0 (18.4) |
52 | 0 | 8 | 19.4 | 38.3 | 50.4 | 46.8 | 36.9 |
53 | 0 | 0 | 0 | 7.4 | 17.8 | 26.1 | 25.9 |
54 | 0 | 0 | 0 | 0 | 6.6 | 14.5 | 17.6 |
55 | 0 | 0 | 0 | 0 | 2.3 | 8.1 | 12.8 |
Io (10 nA) was injected in the middle of the chain, namely cell # 51.
Vx = Vo e-x/λ. When x = λ, Vx = Vo 1/e = 0.368 Vo.
Values given in parentheses (cell #51) are the 1/e values (0.368 x Vo).
But when there were many gj-channels (300, 1000, or 3000), there was substantial ΔVm in the adjoining cells and beyond, as can be Figure 6. This voltage decay was exponential, as demonstrated in Figure 7, in which the ΔVm is plotted on a logarithmic scale. A straight line on such a semilog plot indicates that the voltage fall-off is exponential, with the slope of the straight line being indicative of λ. λ is the distance at which the ΔVm falls to 1/e or 36.8% of the initial value (at x = 0). As indicated in Figure 7, the λ values were 150 μm, 270 μm, and 440 μm with 300, 1000, and 3000 gj-channels, respectively (see Table 5). Thus, the λ value increases nearly in proportion to the square root of the number of gj-channels.
Table 5.
No. of gj-channels | λ (μm) | θov (cm/sec) | ||
A | 300 | 17.3 | 150 | 358 |
B | 1000 | 31.6 | 270 | 874 |
C | 3000 | 54.8 | 440 | 1850 |
Ratios | ||||
C/A | 10.0 | 3.17 | 2.93 | 5.17 |
C/B | 3.00 | 1.73 | 1.63 | 2.12 |
B/A | 3.33 | 1.82 | 1.80 | 2.44 |
N = Number of gj-channels.
The data are given for only those 3 cases in which there was an exponential decay of potential as a function of distance.
Note that the ratios for the effects were always substantially higher for θov than for λ. That is, adding gj-channels had a larger effect on θov than on λ.
Also note that λ varies approximately with the square root of the number of gj-channels.
2. Input resistance (Rin) measurement
To measure the input resistance (Rin) of the chain of cells, different intensities of current (rectangular pulses) were applied intracellularly into cell #51 of the 100-cell chain, and the resulting ΔVm was measured. All of these data are given in Table 6. The data for 1000 gj-channels are plotted in Figure 8. The curve is exactly linear, as expected because rectifying properties were not incorporated into the basic circuit units. In addition, hyperpolarizing and depolarizing currents gave comparable results. The slope of the line plotted gives the input resistance (Rin = ΔVo/Io, where ΔVo is the voltage change at distance x = 0). The measured value for this case (1000 gj-channels) is 8.4 MΩ. The Rin value at zero gj-channels is 29.4 MΩ, a value close to that measured physiologically [21,22]. Table 6 gives the Rin values obtained for all numbers of gj-channels. These values can also be discerned from the ΔVm values measured in cell #51 presented in Figure 6.
Table 6.
No. of gj- Channels | ΔVm in cell #51 (mV) | Rin (MΩ) |
0 | 294 | 29.4 |
10 | 278 | 27.8 |
30 | 253 | 25.3 |
100 | 200 | 20 |
300 | 138 | 13.8 |
1000 | 84 | 8.4 |
3000 | 51 | 5.1 |
Io injected was 10.0 nA
The resistance value measured in the adjacent cells is known as the polarization resistance (Rp), and is proportional to the ΔVm measured in those cells. For example, the Rp values shown in Figure 7 (1000 gj-channels) are 4.7 MΩ for cell #52 (and 50), and 2.6 MΩ for cell #53 (and 49).
The equation for calculating Rin is:
Ω = Ω. |
where ΔV0 is the voltage change at the site of current injection (x = 0) and I0 is the amount of current injected (at x = 0). The equation relating Rin and λ in a cable is:
where ri is the internal longitudinal resistance in Ω/cm, and rj is the junctional resistance in Ω/cm. The 1/2 factor reflects the fact that the injected current spreads in both directions from the point of injection. Since
where rm is the membrane resistance in Ω-cm. Then assuming r0, the external longitudinal resistance, to be zero:
Since in the experiments on length constant, the membrane resistance (rm) and the internal longitudinal resistance (ri) were not altered, whereas rj was lowered by insertion of gj-channels, then Rin should be reduced, as shown in Figures 6, 7 and 8.
C. Propagation velocity vs. length constant (100-cell chain)
The relationship between λ and number of gj-channels is depicted in Figure 9A. This should be compared with Figure 3, which shows the relationship between propagation velocity and number of gj-channels. This same relationship is shown in Figure 9B, but only for those three cases (300, 1000, and 3000 gj-channels) in which there was an exponential fall-off in ΔVm. As shown, propagation velocity varies nearly linear with the number of gj-channels. However, as stated previously, λ varies approximately with the square root of the number of gj-channels (Table 5). Compare the ratios in the √N column with those in the λ column in Table 5. Thus, increasing the number of gj-channels has a great effect on propagation velocity, whereas it has a smaller effect on length constant. Figure 9C gives a plot of the relationship between propagation velocity and length constant.
Contributor Information
Lakshminarayanan Ramasamy, Email: ramasal@ececs.uc.edu.
Nicholas Sperelakis, Email: spereln@ucmail.uc.edu.
References
- Sperelakis N, Ramasamy L. Propagation in cardiac muscle and smooth muscle based on electric field transmission at cell junctions: An analysis by PSpice. IEEE-EMB. 2002;21:130. doi: 10.1109/memb.2002.1175149. [DOI] [PubMed] [Google Scholar]
- Sperelakis N. Propagation of action potentials between parallel chains of cardiac muscle cells in PSpice simulation. Can J Physiol Pharmacol. 2003;81:1. doi: 10.1139/y03-019. [DOI] [PubMed] [Google Scholar]
- Sperelakis N, Kalloor B. Transverse propagation of action potentials between parallel chains of cardiac muscle and smooth muscle cells in PSpice simulations. Biomed Eng Online. 2004;3:5. doi: 10.1186/1475-925X-3-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sperelakis N, Mann J. Evaluation of electric fieldchanges in the cleft between excitable cells. J Theor Biol. 1977;64:71. doi: 10.1016/0022-5193(77)90114-X. [DOI] [PubMed] [Google Scholar]
- Ramasamy L, Sperelakis N. Effect of transverse gap-junction channels on transverse propagation in an enlarged PSpice model of cardiac muscle. Theor Biol Med Modeling. 2006;3:14. doi: 10.1186/1742-4682-3-14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hogues H, Leon L, Roberge F. A model of study of electric field interactions between cardiac myocytes. IEEE Tans Biomed Eng. 1992;30:1232. doi: 10.1109/10.184699. [DOI] [PubMed] [Google Scholar]
- Rohr S. Role of gap junctions in the propagation of the cardiac action potential. Cardiovasc Res. 2004;62:309. doi: 10.1016/j.cardiores.2003.11.035. [DOI] [PubMed] [Google Scholar]
- Rohr S, Kucera J, Fast V, Kleber A. Paradoxical improvement of impulse conduction in cardiac tissue by partial cellular uncoupling. Science. 1997;275:841. doi: 10.1126/science.275.5301.841. [DOI] [PubMed] [Google Scholar]
- Kucera J, Rohr S, Rudy Y. Localization of sodiumchannels in intercalated disks modulates cardiac conduction. Circ Res. 2002;91:1176. doi: 10.1161/01.RES.0000046237.54156.0A. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gutstein D, Morley G, Tamaddon H, Vaidya D, Schneider M, Chen J, Chien K, Stuhlmann H, Fishman G. Conduction slowing and sudden arrythmic death in mice with cardiac restricted inactivation of connexin43. Circ Res. 2001;88:333. doi: 10.1161/01.res.88.3.333. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vaidya D, Tamaddon H, Lo C, Taffet S, Delmar M, Morley G. Nullmutation of connexin43 causes slow propagation of ventricular activation in the late stages of mouse embryonic development. Circ Res. 2001;88:1196. doi: 10.1161/hh1101.091107. [DOI] [PubMed] [Google Scholar]
- Poelzing S, Akar F, Baron E, Rosenbaum D. Heterogeneous connexin43 expression produces electrophysiological heterogeneities across ventricular wall. Am J Physiol: Heart & Circ Physiol. 2003;286:H2001. doi: 10.1152/ajpheart.00987.2003. [DOI] [PubMed] [Google Scholar]
- Picone J, Sperelakis N, Mann J. Expanded model of the electric field: Hypothesis for propagation in cardiac muscle. Math and computer modeling. 1991;15:17. doi: 10.1016/0895-7177(91)90079-M. [DOI] [Google Scholar]
- Sperelakis N, Editorial An electric field mechanism for transmission of excitation between myocardial cells. Circ Res. 2002;91:985. doi: 10.1161/01.RES.0000045656.34731.6D. [DOI] [PubMed] [Google Scholar]
- Sperelakis N. Cell physiology sourcebook. 3rdedition. chapter 24: Cable properties and propagation of action potentials. Appendix I: Academic Press; 2001. p. :407. [Google Scholar]
- Cohen SA. Immunocytochemical localization of rH1 sodium channel in adult rat heart atria and ventricle. presence in terminal intercalated disks. Circulation. 1996;15;94:3083–3086. doi: 10.1161/01.cir.94.12.3083. [DOI] [PubMed] [Google Scholar]
- ModelDB http://senselab.med.yale.edu/senselab/modeldb/
- Ramasamy L, Sperelakis N. Repolarization of the action potential enabled by na+ channel deactivation in PSpice simulation of cardiac muscle propagation. Theoretical Biology and Medical Modelling. 2005;2:48. doi: 10.1186/1742-4682-2-48. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sperelakis N, Murali K. Combined electric field and gap junctions on propagation of action potentials in cardiac muscle and smooth muscle in PSpice simulation. J Electrocardiol. 2003;36:279. doi: 10.1016/j.jelectrocard.2003.08.001. [DOI] [PubMed] [Google Scholar]
- Sperelakis N, Kalloor B, Ramasamy L. Boundary effects influence velocity of transverse propagation of simulated cardiac action potentials. Theoretical Biology and Medical Modelling. 2005;2:36. doi: 10.1186/1742-4682-2-36. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sperelakis N, Hoshiko T, Berne RM. Nonsyncytial nature of cardiac muscle: Membrane resistance of single cells. Am J Physiol. 1960;198:531–536. doi: 10.1152/ajplegacy.1960.198.3.531. [DOI] [PubMed] [Google Scholar]
- Tarr M, Sperelakis N. Weak electronic interaction between contiguous cardiac cells. Am J Physiol. 1964;207:691–700. doi: 10.1152/ajplegacy.1964.207.3.691. [DOI] [PubMed] [Google Scholar]