Abstract
Short-term cardiovascular responses to postural change from sitting to standing involve complex interactions between the autonomic nervous system, which regulates blood pressure, and cerebral autoregulation, which maintains cerebral perfusion. We present a mathematical model that can predict dynamic changes in beat-to-beat arterial blood pressure and middle cerebral artery blood flow velocity during postural change from sitting to standing. Our cardiovascular model utilizes 11 compartments to describe blood pressure, blood flow, compliance, and resistance in the heart and systemic circulation. To include dynamics due to the pulsatile nature of blood pressure and blood flow, resistances in the large systemic arteries are modeled using nonlinear functions of pressure. A physiologically based submodel is used to describe effects of gravity on venous blood pooling during postural change. Two types of control mechanisms are included: 1) autonomic regulation mediated by sympathetic and parasympathetic responses, which affect heart rate, cardiac contractility, resistance, and compliance, and 2) autoregulation mediated by responses to local changes in myogenic tone, metabolic demand, and CO2 concentration, which affect cerebrovascular resistance. Finally, we formulate an inverse least-squares problem to estimate parameters and demonstrate that our mathematical model is in agreement with physiological data from a young subject during postural change from sitting to standing.
Keywords: cardiovascular system, mathematical modeling, cerebral blood flow, gravitational effect, autonomic regulation, cerebral autoregulation
ORTHOSTATIC INTOLERANCE DISORDERS, which are common in every age, are difficult to diagnose and treat. Typically, these disorders, with clinical manifestations including dizziness, syncope, orthostatic hypotension, falls, and cognitive decline, are a result of several biological mechanisms. To develop better strategies to treat and diagnose orthostatic intolerance, it is important to understand the underlying mechanisms leading to these disorders. One of the main mechanisms involved is the short-term cardiovascular regulation of blood flow to the brain, which includes autonomic regulation and cerebral autoregulation. The overall goal of this work is to develop a mathematical model that can predict dynamics in observed cerebral blood flow and peripheral blood pressure data and propose mechanisms that can explain the interaction between autonomic regulation and cerebral autoregulation. To this end, we have developed a mathematical model that can predict these two regulatory mechanisms. To validate the model, we compare model predictions with measurements of arterial finger blood pressure and middle cerebral artery blood flow velocity of a young subject.
On the transition from sitting in a chair to standing, blood is pooled in the lower extremities as a result of gravitational forces. Venous return is reduced, which leads to a decrease in cardiac stroke volume, a decline in arterial blood pressure, and an immediate decrease in blood flow to the brain. The reduction in arterial blood pressure unloads the baroreceptors located in the carotid and aortic walls, which leads to parasympathetic withdrawal and sympathetic activation through baroreflex-mediated autonomic regulation. Parasympathetic withdrawal induces fast (within 1−2 cardiac cycles) increases in heart rate, whereas sympathetic activation yields a slower (within 6−8 cardiac cycles) increase in vascular resistance, vascular tone, and cardiac contractility and a further increase in heart rate (4, 7, 37). Simultaneously, cerebral autoregulation, mediated by changes in CO2, myogenic tone, and metabolic demand, leads to vasodilation of the cerebral arterioles (2, 18, 34, 38).
Our mathematical model includes two submodels: 1) a cardiovascular model that can predict blood pressure and blood flow velocity during sitting and 2) a control model that can predict autonomic and cerebral regulatory mechanisms during the postural change from sitting to standing. Both submodels are based on the same closed-loop model with 11 compartments that represent the heart and systemic circulation. Our previous work (27, 29) also used compartmental models to describe the dynamics of the cardiovascular system. One (27) used an open-loop (3-element windkessel) model to analyze dynamics of cardiovascular control. This model used arterial blood pressure measured in the finger as an input to predict model parameters that describe dynamics of cerebral vascular regulation for young subjects. These parameters were obtained by minimizing the error between computed and measured middle cerebral artery blood flow velocity. Consequently, no equations were used to describe possible mechanisms of the underlying regulation. To further advance this study, we recently developed a seven-compartment closed-loop model (29) that can predict the dynamics observed in the data. This model did not rely on an external input; rather, it included a submodel that describes the pumping of the left ventricle. In addition, the seven-compartment model included simple equations that describe the short-term regulation. This model was able to accurately predict dynamics of cerebral blood flow velocity and arterial blood pressure during sitting (t < 60 s) and standing (t > 80 s), as well as the mean values during the transition from sitting to standing (60 < t < 80 s), but it was not able to predict detailed dynamics during the transition from sitting to standing. Furthermore, we were not able to achieve adequate filling of the left ventricle. To obtain a more accurate model, we developed the 11-compartment model, which overcomes limitations of the 7-compartment model by 1) predicting resistances as nonlinear functions of pressure, 2) adding essential compartments, 3) devising an empirical model of autoregulation, and 4) including a new physiological model describing pooling of blood in the lower extremities due to effects of gravity.
A large body of work that describes cardiovascular control modeling (9−11, 30, 44) is based on predictions of mean values for arterial blood pressure and cerebral blood flow velocity. Consequently, these models cannot predict the pulsatile dynamics of the cardiovascular system. These models use optimal control to minimize the deviation between some observed quantity (e.g., arterial blood pressure) and a given set point. Although this strategy can provide good parameter estimates, optimal control models do not describe the underlying physiological mechanisms. Other modeling strategies have been proposed by Melchior et al. (19, 20) and Heldt et al. (8), who devised pulsatile models that include pulsatility, autonomic regulation, and effects of gravity. The latter was done by changing the reference pressure outside the compartments. However, these models do not include effects of autoregulation. One way to model the effect of autoregulation is to let the cerebrovascular resistance be a function of time, as suggested by Ursino and Lodi (39). However, this work does not include the effects of autonomic regulation. A second group of models described parts of the control system without validation against experimental data (5, 19−21, 31, 32, 35, 40−43). These models used a closed-loop compartmental description of the cardiovascular system combined with physiological descriptions of the control. Although these models can provide qualitative analysis of the system, they cannot be used for quantitative comparisons with data. Furthermore, most of the models in the second group describe the effects of autonomic regulation without including the effects of cerebral autoregulation. In contrast, our model includes autonomic and cerebrovascular regulations and provides quantitative comparisons with physiological data.
MODELING BLOOD PRESSURE AND BLOOD FLOW VELOCITY
Compartmental model for the cardiovascular system.
Our cardiovascular model is based on an 11-compartment closed-loop model. The model is designed to predict blood pressure and volumetric blood flow in the left atrium, left ventricle, aorta, vena cava, arteries, and veins in the upper body, lower body, and head, as well as arteries in the finger (Fig. 1). Each compartment represents all vessels in areas of similar pressure. Hence, in its simplest form, the systemic circuit could consist of one arterial (high-pressure) and one venous (low-pressure) compartment. In our model, we include five arterial compartments and four venous compartments.
Fig. 1.
Compartmental model of systemic circulation. The model contains 11 compartments: 5 represent systemic arteries (brain, upper body, lower body, aorta, and finger), 4 represent systemic veins (brain, upper body, lower body, and vena cava), and 2 represent left atrium and left ventricle. Because the pulmonary system is not included, systemic veins are directly attached to the left ventricle. Each compartment includes a capacitor to represent compliant volume of arteries or veins. All compartments are separated by resistors representing resistance of the vessels. Compartment representing the left ventricle has 2 valves (aortic and mitral). Following terminology from electrical circuit theory, flow between compartments is equivalent to electrical current, and pressure inside each compartment is analogous to voltage. Resistors (R, mmHg · s · cm−3) are marked with zigzag lines, capacitors (C, cm3/mmHg) with dashed parallel lines inside the compartments, and aortic and mitral valves with short lines inside the compartment that represents the left ventricle. Cer, cerebral; see Glossary for other abbreviations.
The 11 compartments depicted in Fig. 1 are chosen to ensure that the level of detail in the model is adequate to describe the complex dynamics observed in the data and, at the same time, is not too complex to be solved computationally. Four compartments that represent the upper body and the legs are included to model venous pooling of blood and sympathetic contraction of the vascular bed. Two compartments that represent the brain are included to model effects of cerebral autoregulation and to enable model validation against cerebral arterial blood flow velocity measurements. One compartment that represents the finger is included to enable model validation against arterial blood pressure measured in the finger. To determine cardiac output and venous return, two compartments are included to represent the aorta and vena cava. Finally, to obtain a closed-loop model, it is necessary to include a source (i.e., the heart) that pumps blood through the system. Consequently, two compartments are included to represent the left atrium and left ventricle. Our previous work (29) included only the left ventricle; without an atrium, it is not possible to achieve adequate filling of the heart.
The major system not included in our model is the pulmonary circulation. Addition of compartments that represent the pulmonary circulation would require more parameters, which would increase the computational complexity. Instead, the pulmonary circulation is represented as a resistance between the vena cava and the left atrium.
To study dynamics of postural change from sitting to standing, it is not important to know how blood is distributed among various inner organs. Hence, the upper body is simply represented by an arterial and a venous compartment. Each compartment is represented by a compliance element (inverse elasticity) and is separated by resistance to flow. The design of the systemic circulation with arteries and veins separated by capillaries provides some resistance and inertia to the volumetric flow rate. In our model, we include effects of resistance between compartments but neglect effects due to inertia. The major resistance to flow is located in peripheral regions between compartments that represent arteries and veins. Compartments that represent large conduit vessels are also separated by resistances that represent the overall resistance of the compartment. Resistances between conduit vessels are very small compared with peripheral resistances.
The description of blood pressure and volumetric flow in a system consisting of compliant compartments (capacitors) and resistors is equivalent to that of an electrical circuit (Fig. 1), where blood pressure plays the role of voltage and volumetric flow rate plays the role of current. To compare our model with data, we assume that the diameter of the middle cerebral artery remains constant, such that blood flow velocity can be obtained by scaling volumetric blood flow by a constant factor that represents the area of the vessel. Recent measurements of middle cerebral artery diameter by magnetic resonance imaging combined with transcranial Doppler assessment of cerebral blood flow velocity have demonstrated that the middle cerebral artery diameter does not change, despite large changes in cerebral blood flow velocity elicited by stimuli such as lower body negative pressure and CO2 changes (36).
To predict blood pressure and blood flow within and between the compartments, we base our model on volume conservation laws (41). Blood pressure and volumetric blood flow can be found by computing the volume and change in volume for each compartment. The equations that represent the arterial and venous compartments are similar. For each of these compartments, the stressed volume V = Cp (cm3, volume pumped out during 1 cardiac cycle), where C (cm3/mmHg) is compliance and p (mmHg) is blood pressure. The cardiac output (CO) from the heart is given by CO = HVstroke (cm3/s), where H (beats/s) is heart rate and Vstroke (cm3/beat) is stroke volume. For each compartment, the net change of volume is given by
(1) |
where q (cm3/s) is determined analogously to Kirchhoff’s current law and R is the resistance to flow. Several compartments have more than one inflow or outflow. For example, the compartment that represents the aorta has three outflows (qout = qaf + qau + qac), whereas the compartment that represents the vena cava has three inflows (qin = qafp + qvu + qvc; Fig. 1).
To model the left ventricle as a pump, the position of the mitral and aortic valves must be included. During diastole, the mitral valve is open, while the aortic valve is closed, allowing blood to enter the left ventricle. Then isometric contraction begins, increasing the ventricular pressure. Once the ventricular pressure exceeds the aortic pressure, the aortic valve opens, propelling the pulse wave through the vascular system. For healthy young people, both valves cannot be open simultaneously. To incorporate the state of the valves, we have modeled the resistances (Rav and Rmv; Fig. 1) as follows
where v represents mitral and aortic valves. This equation results in a large resistance (and no flow) while the valve is closed and a small resistance (and normal flow) while the valve is open. The minimum (min) value is introduced to avoid numerical problems due to large numbers.
A system of differential equations is obtained by differentiating the volume equation V = Cp and inserting Eq. 1
(2) |
The circuit in Fig. 1 gives rise to a total of nine differential equations in dp/dt, one for each of the arterial and venous compartments. For the two compartments that represent the atrium and the ventricle, differential equations are kept as dV/dt. For these two compartments, blood pressure is computed explicitly as a function of volume (see Ventricular and atrial contraction; for a complete list of equations, see the APPENDIX).
Ventricular and atrial contraction.
Atrial and ventricular contraction leads to an increase in blood pressure from the low values observed in the venous system to the high values observed in the arterial system. Our model is based on the work by Ottesen and coworkers (6, 33), which predicts atrial ( pla) and ventricular (plv) pressure as a function volume and cardiac activation of the form
(3) |
The parameter a (mmHg/cm3) is related to elastance during relaxation, b (cm3) represents volume at zero diastolic pressure, c(t) (mmHg/cm3) represents contractility, and d (mmHg) is related to the volume-dependent and volume-independent components of developed pressure.
The activation function g(t), which is defined over the length of one cardiac cycle, is described by a polynomial of degree (n;m): g(t) = f(t)/f(tp) with
(4) |
where T (s) is the duration of the cardiac cycle [t̃ = mod(t;T), s], β(H) (s) denotes the onset of relaxation, H = 1/T(1/s) is heart rate, n and m characterize the contraction and relaxation phases, and pp is the peak value of the activation. The ability to vary heart rate is included in the isovolumic pressure equation (Eq. 3) by scaling time and peak values of the activation function f. The time for peak value of the contraction [tp(s)] is scaled by introducing a sigmoidal function, which depends on the heart rate (H), of the form
(5) |
1where θ represents the median, ν represents steepness, and tm (s) and tM (s) denote the minimum and maximum values, respectively. The peak ventricular pressure [pp (mmHg)] is scaled similarly using a sigmoidal function of the form
(6) |
where φ represents the median, η represents steepness, and pm (mmHg) and pM (mmHg) denote minimum and maximum values, respectively. Finally, the time for onset of relaxation is modeled by
(7) |
which is obtained by recognizing that tp is related to the parameter β in the isovolumic pressure model (3). Initial values for all parameters were obtained from the work by Ottesen and Danielsen (33), in which parameters were based on data from dogs. To obtain human values for the young subject studied in this work, we identified the parameters in Table 1 during our model validation.
Table 1.
Steady-state parameters before and after optimization
Initial | Optimized | |
---|---|---|
Resistance/compliance | ||
Rav | 0.030 | 0.1149 |
Rau | 0.072 | 0.1853 |
Ral | 0.087 | 0.0043 |
Raf | 0.183 | 0.5456 |
Rac | 0.409 | 0.3177 |
Raup | 1.565 | 1.8565 |
Ralp | 6.522 | 7.5854 |
Rafp | 17.5 | 17.8953 |
Racp | 6.696 | 7.0838 |
Rmv | 0.007 | 0.0164 |
Rv | 0.033 | 0.0368 |
Rvu | 0.001 | 0.000 |
Rvl | 0.174 | 0.1193 |
Rvc | 0.957 | 1.2875 |
Ca | 0.084 | 0.0732 |
Cau | 0.6160 | 0.7255 |
Cal | 0.940 | 0.9881 |
Caf | 0.174 | 0.2353 |
Cac | 0.159 | 0.0892 |
Cv | 2.931 | 2.5181 |
Cvu | 15.276 | 15.4531 |
Cvl | 6.038 | 6.2778 |
Cvc | 2.847 | 2.3007 |
fact | 0.1415 | 0.2079 |
α | 1.4287 | 2.3220 |
Heart | ||
av | 0.0003 | 0.0009 |
bv | 5 | 4.9122 |
cv | 6.4 | 6.9100 |
dv | 1 | 0.8310 |
nv | 2 | 3.6659 |
mv | 2.2 | 1.7369 |
vv | 9.9 | 11.0201 |
θv | 0.951 | 0.9213 |
ηv | 17.5 | 17.6658 |
φv | 1 | 1.1560 |
Tm,v | 0.186 | 0.1310 |
TM,v | 0.280 | 0.2305 |
Pm,v | 0.842 | 1.1074 |
PM,v | 1.158 | 1.2385 |
aa | 0.002 | 0.0002 |
ba | 5 | 4.1074 |
ca | 6.4 | 6.4325 |
da | 1 | 1.1668 |
na | 1.9 | 1.9501 |
ma | 2.2 | 1.9767 |
va | 9.9 | 10.8595 |
θa | 6.2778 | 1.9998 |
ηa | 17.5 | 16.5386 |
φa | 1 | 2.1152 |
Tm,a | 0.186 | 0.2487 |
TM,a | 0.280 | 0.3560 |
Pm,a | 0.842 | 1.0065 |
PM,a | 0.990 | 1.2100 |
Nonlinear Resistances
To our knowledge, previous modeling contributions (see the introduction) assume that, during steady state (i.e., sitting, for t ≤ 60 s), the small resistances between compartments that represent large conduit vessels are constant. Nevertheless, from the theory of fluid mechanics, it is well known that the resistance depends on the radii of the vessels and that the radii themselves depend on the corresponding transmural pressure.
Our investigation has shown that such dependencies are important to include in regions that represent vessels with large diameters and high blood pressure (i.e., large arteries), whereas they are less important in regions of low blood pressure (i.e., the venous system). Furthermore, these “passive” changes in diameters are also negligible in regions with small vessels (i.e., small arteries and arterioles), where autonomic responses are active and dominate the change in vessel diameters. Our previous work (29) did not include nonlinear arterial resistances; therefore, we were not able to obtain a sufficiently wide pulse pressure immediately after postural change from sitting to standing.
To model nonlinearities for these resistances, we base our derivation on Poiseuille’s law. For flow in a cylinder with circular cross-sectional area, Poiseuille’s law predicts the resistance to flow (14) as
where R (mmHg·s·cm−3) is resistance, r (cm) is radius of the vessel, η (mmHg·s) is viscosity of blood, and l (cm) is length of the cylindrical vessel. If it is assumed that length of the vessel is constant
(8) |
The first relation comes from Poiseuille’s law, the second can be obtained by assuming a fixed length l, and the third can be obtained by assuming the validity of the pressure volume relation V = Cp. In the compartmental model discussed above each compartment, a number of vessels are lumped together; as a result, we have no specific information about r. The relation in Eq. 8 implies that the resistance is inversely proportional to pressure squared. For real arteries and veins, the resistance will have maximum and minimum values. Hence, we have chosen to model this nonlinear relation using a sigmoidally decreasing function of the form
(9) |
where RM (mmHg·s·cm−3) and Rm (mmHg·s·cm−3) are the maximum and minimum values for resistance and p (mmHg) is the blood pressure in the compartment that precedes the resistance. [In our implementation, the actual blood pressure oscillates too much; therefore, for numerical stability, we base the prediction of R on the corresponding mean arterial blood pressure, (t) (mmHg).] As shown in Fig. 2, the mean arterial blood pressure oscillates with the same frequency but with smaller amplitude than pa; k represents the steepness of the sigmoid, and the parameter α2 is calculated to ensure that R returns to the value of the controlled parameter found during steady state. For k = 2, the slope of the sigmoid approximates the relation in Eq. 8. However, the relation in Eq. 8 is valid only for a steady flow. Blood flow in arteries is unsteady, and the flow through a given vessel depends on the state of the vessel. Consequently, as shown in Table 2, we should not expect that k = 2.
Fig. 2.
Mean arterial pressure, a(t)(pam), for 45 ≤ t ≤ 90 s, computed as a continuous function by solving differential Eq. 16. Similar results were obtained for pau(t).
Table 2.
Optimized parameters
Initial | Optimized | |
---|---|---|
pa | 92.8 | |
pau | 90.0 | |
τCv | 10.00 | 18.57 |
τCa | 10.00 | 13.67 |
τR | 5.0 | 23.03 |
τS | 5.0 | 0.076 |
hH | 50.0 | 46.73 |
hk | 3.0 | 3.92 |
δ | 0.4 | 1.26 |
k (Ral) | 5.0 | 1.48 |
RM (Ral) | 4 × Rssal | 1.69 |
Rm (Ral) | Rssal/4 | 1.1 × 10−3 |
k (Rac) | 5.0 | 8.79 |
RM (Rac) | 4 × Rssac | 2.49 |
Rm (Rac) | Rssac / 4 | 1.3 × 10−2 |
k (Raf) | 5.0 | 3.83 |
RM (Raf) | 4 × Rssaf | 0.15 |
Rm (Raf) | Rssaf / 4 | 2.9 × 10−5 |
k (Raup) | 5.0 | 5.74 |
RM (Raup) | 4 × Rssaup | 14.58 |
Rm (Raup) | Rssaup / 4 | 0.13 |
k (Ralp) | 5.0 | 10.57 |
RM (Ralp) | 4 × Rssafp | 145.19 |
Rm (Ralp) | Rssafp / 4 | 0.41 |
k (Rafp) | 2.0 | 3.69 |
RM (Rafp) | 4 × Rssafp | 64.81 |
Rm (Rafp) | Rssafp / 4 | 0.16 |
k (cv) | 2.0 | 4.62 |
RM (cv) | 4 × cssvtr | 17.27 |
Rm (cv) | cssvtr / 4 | 1.04 |
k (ca) | 2.0 | 4.58 |
RM (ca) | 4 × cssvtr | 11.99 |
Rm (ca) | cssvtr / 4 | 0.94 |
k (Ca) | 2.0 | 0.38 |
CM (Ca) | 4 × Cssa | 4.3 × 10−2 |
Cm (Ca) | Cssa / 4 | 4.8 × 10−4 |
k (Cau) | 2.0 | 17.22 |
CM (Cau) | 4 × Cssau | 1.01 |
Cm (Cau) | Cssau / 4 | 0.42 |
k (Cal) | 2.0 | 13.90 |
CM (Cal) | 4 × Cssal | 15.25 |
Cm (cal) | Cssal / 4 | 0.82 |
k (Cac) | 2.0 | 4.05 |
CM (Cac) | 4 × Cssac | 0.23 |
Cm (Cac) | Cssac / 4 | 7.0 × 10−2 |
k (Caf) | 2.0 | 81.34 |
CM (Caf) | 4 × Cssaf | 0.46 |
Cm (Caf) | Cssaf / 4 | 1.7 × 10−2 |
k (Cv) | 3.0 | 0.47 |
CM (Cv) | 5 × Cssv | 15.32 |
Cm (Cv) | Cssv | 0.52 |
k (Cvu) | 3.0 | 12.90 |
CM (Cvu) | 5 × Cssvu | 55.86 |
Cm (Cvu) | Cssvu / 5 | 1.93 |
k (Cvl) | 3.0 | 47.93 |
CM (Cvl) | 5 × Cssvl | 277.94 |
Cm (Cvl) | Cssvl / 5 | 0.17 |
k (Ccv) | 3.0 | 15.71 |
CM (Ccv) | 5 × Cssvc | 13.89 |
Cm (Cvc) | Cssvc / 5 | 0.19 |
Constants a and au denote pressure set points used in control equations. Time constants (τi) denote time delay involved with controlled variables. Parameters for gravity denote maximum height needed to obtain observed pressure drop, and a small delay (δ) from which the subjects stands up. Optimized values for resistances and capacitors include ki, which represent the steepness of the sigmoid, and a maximum (RM or CM) and a minimum (Rm or Cm) value. Optimized values for Rau and Rac are shown in Figs. 4 and 5. ss, Steady state; see Glossary for other obbreviations.
In our model 3, resistances are computed as functions of pressure: . The resistance of the aorta (Rau) could also be modeled using this method. Initial investigations showed that other mechanisms, e.g., autoregulation or autonomic regulation, may also affect Rau. As a consequence, we have used an empirical model to estimate Rau (see MODELING AUTONOMIC REGULATION AND CEREBRAL AUTOREGULATION. Cerebral autoregulation).
Gravitational effect.
Gravitational effects are essential during postural change from sitting to standing. Consider a cylindrical vessel with length Δz (cm) and time-invariant cross-sectional area A (cm2), i.e., dA/dt = 0. Assume that there is no velocity across the vessel and that the blood pressure is only a function position along the vessel. Hence, dv/dr = 0, where v (cm/s) and r (cm) denote the velocity and radii, respectively, and the volumetric flow rate becomes q = Av (cm3/s). Finally, assume that the drag force due to viscous shear is proportional to q. Thus the drag force per cross-sectional area unit is proportional to q; i.e., the drag force can be written as –RAq, where R (mmHg·s·cm−3) may be interpreted as the resistance. In steady state, the resistance R is given by Poiseuille’s law (23)
To derive the mathematical model, we proceed by balancing inertial forces with the drag force, the pressure force, and the gravitational force. The inertial force is given by
where ρ = 1.055 (g/cm3) is the density of the fluid and M (g) is the mass of the fluid contained in a piece of the vessel with length Δz (cm) and cross-sectional area A (cm2; Fig. 3). Thus Newton’s second law, which describes balancing of forces, gives
where g = 981 (cm/s2) is the gravitational acceleration. From this, it follows that
(10) |
where L = ρΔz/A(1/s2) is the inertance and Δh = Δzcos(ψ) = hin – hout (cm) is the vertical difference of the vessel inlet (at hin where pin and pout represent pressure at the inlet and outlet, respectively). During steady state, Eq. 10 reduces to
(11) |
When modeling postural change from sitting to standing, we substitute Eq. 11 for Kirchhoff’s current law. In the limit g → 0, Eq. 11 approaches the normal form of Kirchhoff’s current law given in Eq. 1. In the case of energy conservation (R → 0), Bernoulli’s law for steady flow is recovered; as a result, pin + ρghin = pout + ρghout. Thus Kirchhoff’s current law is still valid if we interpret p as the hydrostatic pressure p + ρgh.
Fig. 3.
Vessel segment with cross-sectional area A(cm2) and length Δz(cm). At one end, pressure is pin (mmHg); at the other end, pressure is pout (mmHg). Vessel is at an angle τ with respect to gravity g(g/cm2) and at an angle ψ with respect to the horizontal axis. Difference in vertical latitude is Δh=Δzcos(ψ) (cm).
To capture the transition from sitting to standing, h is defined for the lower body compartments as the exponentially increasing function
(12) |
where Tup (s) is the time at which the subject stands up, hM (cm) is the maximum height needed for the mean arterial blood pressure in the finger to drop as indicated by the data, and δ (s) is the latency for the transition to standing. In our experiments, the subjects sit with their legs elevated and the hand, where the pressure is measured, held by a sling at the level of the heart. Therefore, compartments that represent the heart and the finger are not affected by gravity. Compartments that represent the brain and the upper body are exposed to constant hydrostatic conditions, which are neglected in the current formulation. However, compartments that represent the legs are affected by gravity. Consequently, equations for the flows qal and qvl will be modified as described in Eq. 11
In the first of these equations, hin = 0 and hout = h, where h is computed using Eq. 12. In the second of these equations, hin = h and hout = 0.
MODELING AUTONOMIC REGULATION AND CEREBRAL AUTOREGULATION
Two main control mechanisms play a role: autonomic regulation and cerebral autoregulation. Autonomic regulation is mediated via the autonomic nervous system and causes changes of resistances in the vascular bed, compliance, heart rate, and cardiac contractility. Autoregulation is a local control that maintains cerebral perfusion, despite changes in systemic pressure. Autoregulation is mediated via changes in myogenic tone, metabolic demands, and CO2 concentration.
Autonomic regulation.
Autonomic regulation is modeled as a pressure regulation where heart rate (H, beats/s), cardiac contractility (ca and cv, mmHg/cm3), peripheral systemic resistance (Raup and Ralp, mmHg·s·cm−3), and systemic compliance (Ca, Cau, Cal, Cac, Caf, Cv, Cvu, Cvl, and Cvc, cm3/mmHg) are functions of mean arterial blood pressure (a, mmHg).
The change in the controlled parameters is modeled using a first-order differential equation with a set-point function dependent on a
(13) |
This simple model is able to predict the observed dynamics. The parameter x(t) is controlled, xctr(pa) is the set-point function, and τ (s) is a time constant that characterizes the time required for the controlled variable to obtain its full effect. Different values of τ were used for control of cardiac contractility, compliance, and resistance (Table 2). As described earlier, autonomic regulation yields increases in peripheral vascular resistance, heart rate, and cardiac contractility. Heart rate is directly obtained from data. Hence, it is not modeled using the set-point function (13). To obtain increases in peripheral resistances (Raup, Ralp, and Rafp) and cardiac contractility (cla and clv) in response to the decrease in arterial blood pressure, the following set-point function has been used
(14) |
A sigmoidal function was used, because it displays saturation; i.e., the function has a maximum and a minimum value corresponding to maximum dilation and maximum constriction of the vessels. In addition, vascular tone is increased, leading to a decrease in compliance in response to a decrease in arterial blood pressure. Hence, for compliance, the set-point function has the form
(15) |
Equation 14 gives rise to a decreasing sigmoidal curve (i.e., for a decreasing pressure, the value of xctr will increase), whereas Eq. 15 gives rise to an increasing sigmoidal curve (i.e., for a decreasing pressure, the value of xctr will decrease). The parameters xm and xM are minimum and maximum values for the controlled parameter x(t). The parameter α2 is calculated to ensure that x(t) returns the value of the controlled parameters found during steady state. Initial values of parameters for k, xm, and xM are from Danielsen (5) (Table 2).
These control equations (Eqs. 13−15) are formulated as functions of mean arterial blood pressure. However, our model describes the instantaneous (pulsatile) pressure. Mean values are computed as weighted averages, where the present is weighted higher than the past
(16) |
The normalization factor N is introduced to ensure that the correct mean arterial blood pressure is obtained for pa = 1, i.e.,
(17) |
Because our mathematical model is described by differential equations, it is more efficient to implement a differential equation to compute the mean arterial blood pressure. Hence, we differentiate Eq. 16 to obtain
(18) |
A similar equation is used to calculate pau.
Cerebral autoregulation.
On the transition to standing, cerebral autoregulation mediates a decline in cerebrovascular resistance (Racp) in response to the decrease in arterial blood pressure. In addition, the autonomic system may also play a role, by decreasing the cerebrovascular resistance due to cholinergic vasodilation or by increasing the resistance due to release of norepinephrine (7). Consequently, it is not trivial to develop an accurate physiological model that describes cerebral autoregulation. Our strategy in this work has been to use a piecewise linear function with unknown coefficients to obtain a representative function that describes the time-varying response of the cerebrovascular resistance. Once such a function is obtained, we can interpret the result in terms of the underlying physiology. To obtain such a function, we have parameterized the cerebrovascular resistance using piecewise linear functions of the form
(19) |
where Hi represents the standard “hat” functions given by
(20) |
The unknown coefficients γi will be estimated together with the other control parameters in Table 2. As described above, we have used a similar method to estimate the resistance Rau, which may be affected by passive nonlinear resistances and autonomic regulation.
PARAMETER ESTIMATION
Estimation of model parameters has been done in a number of steps. First, we used physiological properties of the system to determine initial values for all parameters and variables (Table 1). Then we solved the steady-state problem (without including effects of gravity and regulation); i.e., we solved 11 equations of the form of Eq. 2, one for each compartment. During steady state, all resistances and capacitors were kept constant; hence, terms that involve p(dC)/dt = 0. These equations are combined with Eqs. 3−7, which determine pressures in the left atrium and ventricle, and Eq. 18, which determines the mean arterial pressures a and au. Finally, we estimated a constant factor used to calculate cerebral blood flow velocity vacp = qacp/fact (cm/s). We have used a constant factor (fact), because we assume that the cross-sectional area of the middle cerebral artery does not change significantly (36). These equations involve a total of 53 parameters that were estimated using a nonlinear optimization method, the Nelder-Mead algorithm, which is based on function information computed on sequences of simplexes (13). Estimated parameter values are shown together with initial values in Table 1. To obtain the best possible parameter values, we used the following cost function to minimize the difference between measured and computed values of cerebral blood flow velocity and finger pressure
where v = vacp and p = paf. The superscripts d and c refer to data and corresponding computed values, respectively. In the first two sums, i = [1:N], where N is the number of data points. To compare the computed values xc and the measured data values xd (x = v,p), interpolation is used to evaluate the computed value at the same points in time where the data are obtained. Each term is divided by the number of points and the mean value of the measured data. Our model is not able to predict second-order oscillations (see Fig. 7B). The error due to poor resolution of second-order oscillations is of the same order of magnitude as the error due to poor resolution of the maximum and minimum values. However, for our modeling purpose, it is important to resolve the maximum and minimum values, but it is not important to resolve second-order oscillations. To reward good resolution of the maximum and minimum values, we have added four additional sums predicting the error between systolic and diastolic (sys and dia, respectively) computed and measured values of vacp and paf. Because of the nature of the pulse wave, only one minimum and maximum value is obtained per period; hence, i = [1:M], where M is the number of periods for 45 ≤ t ≤ 90 s.
Fig. 7.
A: middle cerebral blood flow velocity and arterial finger blood pressure during sitting, i.e., for 0 ≤ t ≤ 60 s. B: magnification of 29.4 ≤ t ≤ 34.2 s in A. During steady state, vacp(t) and paf(t) were obtained by solving differential equations of the form of Eq. 2 (see APPENDIX for all equations). Dark traces, result of our computations; gray traces, corresponding data. Our model can accurately predict blood flow velocity and blood pressure profiles while the subject is sitting. As shown in B, our model is not able to capture secondary oscillations observed in the data.
After the steady-state parameters (constant values of all resistances and compliances) were obtained, we included all equations that describe the control and ran another optimization to fit parameters that describe the control functions. This second optimization included 27 ordinary differential equations: 11 of the form of Eq. 2, 2 of the form of Eq. 18, and 14 of the form of Eq. 13. These equations are solved together with the heart model described in Eqs. 3−7, equations for passive nonlinear resistances (Eq. 9), Eq. 12, which determines the height used to calculate gravitational pooling in the veins, and the piecewise linear functions used to parameterize Racp and Rau. This second optimization gave rise to a total of 111 parameters that were optimized: 59 parameters are shown in Table 2, and 52 parameters used to parameterize Racp and Rau are shown in Figs. 4 and 5. During this second optimization, all parameters found during steady-state (i.e., during sitting, for t < 60 s) optimization remained constant (at the optimized values). In general, the inverse problem for parameter estimation does not provide a unique solution. In addition, the optimized parameters depend on the initial guesses and on the optimization algorithm.
Fig. 4.
Cerebral vascular resistance [Racp(t)] for 45 ≤ t ≤ 90 s, computed using piecewise linear Eq. 19. *, 26 values used to estimate cerebrovascular resistance. Shortly after transition to standing (at t = 60 s), cerebral autoregulation leads to a decrease in cerebrovascular resistance followed by an increase to a new steady-state value slightly higher than the steady-state value during sitting (for t≤ 60 s).
Fig. 5.
“Passive” resistances between compartments that represent large arteries. A: Rau(t) fitted, using Eq. 19, with 26 values (*). B: Rac(t) computed using Eq. 9. Rau and Rac are depicted for 45 ≤ t ≤ 90 s. Rau and Rac increase in response to decreasing pressure and then decrease to a new steady-state value. Models for Ral(t) and Raf(t) are similar to that for Rac(t) and show similar trends.
The differential equations from our mathematical model, Eqs. 2, 13, and 18, are solved using MATLAB’s (MathWorks, Natick, MA) differential equations solver “ode15s.” Initial values for the resistance and compliance parameters were found from the distribution of the total blood volume between compartments and steady-state estimates for the pressure values in the various compartments. The blood volume distribution is obtained using the quantities suggested by Beneken and DeWit (3). Initial values for the resistances and compliances were based on previously reported values for blood volumes and flow rates (3), whereas blood pressure values were obtained from standard physiology literature (4). Volumes for each compartment are given by
where Vunstr is the unstressed volume, i.e., the part of the volume that is not pumped out during the cardiac cycle. Therefore, initial values for compliance and resistance are calculated by
These initial values are given in Table 1. Initial values for pressures and unstressed volumes are given in Table 3.
Table 3.
Initial values for pressures and total and unstressed volumes
Parameter | Value |
---|---|
Pressure, mmHg | |
pa | 70.0 |
pau | 72.0 |
pal | 73.0 |
paf | 70.0 |
pac | 70.0 |
pv | 2.0 |
pvu | 2.1 |
pvl | 2.2 |
pvc | 43.0 |
Total volume, cm3 | |
Vlv | 68.0 |
Vla | 172.0 |
Va | 40.0 |
Vau | 300.0 |
Val | 233.7 |
Vaf | 80.0 |
Vac | 70.0 |
Vv | 183.2 |
Vvu | 1909.5 |
Vvl | 724.6 |
Vvc | 391.4 |
Unstressed volume, cm3 | |
32.0 | |
240.0 | |
151.9 | |
64.0 | |
56.0 | |
168.5 | |
1756.7 | |
652.1 | |
360.1 |
EXPERIMENTAL DATA
Our model was validated against continuous physiological data from a young subject during the transition from sitting to standing. In particular, we used arterial blood pressure measurements from the finger and arterial blood flow velocity measurements from the middle cerebral artery (15). Each subject was instrumented with a three-lead ECG (Collins) to obtain heart rate and a photoplethysmographic cuff on the middle finger of the right hand supported at the level of the right atrium to obtain noninvasive beat-by-beat blood pressure (Finapres, Ohmeda). The middle cerebral artery was insonated by placement of a 2-MHz Doppler probe (Nicolet Companion) over the temporal window to obtain continuous measurements of blood flow velocity. The envelope of the velocity waveform was derived from the fast Fourier transform of the Doppler signal, as described by Aaslid et al. (1). All physiological signals were digitized at 500 Hz (Windaq, Dataq Instruments) and stored for offline analysis. Blood pressure reduction of ∼30 mmHg on the transition to standing was used as a challenge for cerebral autoregulation. Subjects sat in a straight-backed chair with their legs elevated at 90° in front of them. They were then asked to stand. Standing was defined as the moment both feet touched the floor. Subjects performed two 5-min trials in the sitting position followed by standing for 1 min and one 5-min trial in the sitting position followed by 6 min of standing.
RESULTS
We were able to obtain excellent agreement between simulations and measured data. Figure 6 shows the characteristic features of the measured data. After the transition to standing at t = 60 s, blood pressure (systolic, diastolic, and mean values) dropped significantly. At the same time, mean blood flow velocity decreased during the transition from sitting to standing (dark line through pulsatile velocity data). However, although systolic and diastolic values of pressure decreased, only the diastolic value of the blood flow velocity was diminished. The systolic values remained at baseline or were even slightly increased. This yields a significant widening of the pulsatile flow, a feature typical for young people with normal regulatory responses (15).
Fig. 6.
Measured arterial blood pressure in the middle finger [paf(t)], cerebral blood flow velocity [vacp(t)], and heart rate [H(t)] for a young subject for 45 ≤t ≤ 90 s. Gray traces, time-varying values; dark traces, corresponding beat-to-beat mean values. Heart rate is obtained as follows: H = 1/T, where T(s) is cardiac cycle duration. Immediately after transition to standing (at t = 60 s), pulsatile and mean blood pressure dropped significantly, mean blood flow velocity dropped, and pulsatile blood flow velocity widened (i.e., systolic value increased, and diastolic value decreased). Initially, heart rate increased and then reached a new steady state at a higher level than during sitting.
First, we evaluated our model’s ability to reproduce the dynamics during steady state (i.e., during sitting, for t < 60 s). We applied initial parameter values from physiological considerations (see above). Then we fitted our model [without including equations that describe resistances of large arteries as nonlinear functions of pressure (Eq. 9) and those that describe active control (Eqs. 13 and 19)] to the data set. The duration of the cardiac cycles was obtained from the ECG (Fig. 6). Simulation results in Fig. 7 show that we obtained an excellent agreement between our model and the data during steady state. However, our model is not able to resolve details of the secondary oscillations observed within each cardiac cycle (Fig. 7B), a feature that is not included in our heart model.
The second step in validating our model is to illustrate that we can model effects of venous pooling after the transition to standing. Venous pooling results in dramatic reductions of cerebral blood flow velocity and arterial pressure (Fig. 8): with the parameters listed in Tables 1 and 2, it is possible to decrease blood flow velocity and pressure. Two observations should be noted: 1) although we did not include effects of the control, we still see an increase in heart rate, because heart rate information is obtained from the data (Fig. 6), and 2) although blood flow velocity and pressure drop immediately after standing (at 60 s), the pulse amplitude for blood flow velocity and pressure remains very narrow.
Fig. 8.
Cerebral blood flow velocity and arterial finger blood pressure for 45 ≤ t ≤ 90 s. Effect of standing is shown without active control mechanisms. A: blood flow velocity and blood pressure (dark traces) decrease as a result of redistribution of volumes from changes in hydrostatic pressure. Results were obtained by solving equations of the form of Eq. 2, where gravity is included, as shown in Eq. 11. B: effect of including nonlinear functions of pressure for large arterial resistances as described in Eq. 9. Immediately after standing (from 60 ≤ t≤ 65 s), pulse pressure is much wider. Dark traces, simulated model results; gray traces, data.
Next, we demonstrated the impact of the nonlinear relation between pressure and the vascular resistance of the large arteries (see MODELING BLOOD PRESSURE AND BLOOD FLOW VELOCITY. Nonlinear resistance); i.e., we let Ral(pau), Rau(pa), Rac(pa), and Raf(pa) be functions of pressure. We used the same values for all remaining parameters, and the result of this simulation is shown in Fig. 8B. The pulse pressure amplitude is higher immediately after the transition to standing (from 60 ≤ t ≤ 65 s); thus the model better represents measured values (cf. dark lines in Fig. 8, A and B, in the transition region, for 60 ≤ t ≤ 65 s).
The third step involved incorporation of all active control mechanisms. Results that include effects of autonomic regulation and autoregulation are shown in Fig. 9. Our model is able to predict the change in the overall profile during the transition from sitting to standing. The only minor difference is that the data include a slight overshoot in pressure in the transition to standing.
Fig. 9.
Autonomic regulation and cerebral autoregulation of arterial finger blood pressure and cerebral blood flow velocity for 45 ≤ t≤ 60 s. Model is able to reproduce data well. Dark traces, model simulations; gray traces, data. Results were obtained by solving cardiovascular equations of the form of Eq. 2, including gravity, as described in Eq. 11, passive resistances (Eq. 9), and autonomic regulation and cerebral autoregulation (Eqs. 13 and 19). The main region, where the model does not capture the dynamics of the data, is just before return to steady state during standing, i.e., for t ∼ 60 s.
Autonomic regulation was included using a model that predicts parameters as a function of pressure. Although this method does not incorporate effects of sympathetic vs. para-sympathetic activation, it does include net effects of neurogenic regulation. Effects of cerebral autoregulation were modeled using the empirical model described in Eq. 19. We chose to include 26 points to represent the dynamics of cerebral vascular resistance, Racp (Fig. 4). Figure 4 shows that Racp decreases because of autoregulation in response to the decrease in pressure. From earlier work (27), we expected an initial increase before the decrease; however, the model used in our previous work was much simpler than the model used in the present work. In particular, the parameter that represents peripheral resistance (Rp) in our earlier work lumps the peripheral resistance from the entire body, i.e., it combines Racp, Raup, Rafp, and Ralp. Consequently, it can be difficult to use Rp to describe the dynamics of the cerebrovascular resistance Racp, as we attempted to do in our earlier work.
The resistance of the upper body (Rau) was also modeled using a piecewise linear model with unknown parameters, as described elsewhere (19). We expected that Rau may depend on autonomic regulation and may be a nonlinear passive function of pressure. This resistance follows trends predicted by remaining resistances that represent the large arteries (Fig. 5).
Finally, Fig. 10 depicts the dynamics of some of the controlled variables, e.g., arterial resistance (Raup), cardiac contractility of the left ventricle (clv), and venous compliance in the upper body (Cvu). These results display quite different dynamics of the three types of variables. In particular, the compliance and peripheral resistance do not reach a steady state during the 10 s after the transition from sitting to standing (from 80 ≤ t ≤ 90 s), perhaps because the dynamics that change the ventricular contractility occur over a much faster time scale than those that affect resistances and compliances. Finally, the dynamics of other resistances, capacitors, and atrial contractility are similar to the parameters shown in Fig. 10.
Fig. 10.
Dynamics of controlled variables for 45 ≤ t ≤ 90 s. A: peripheral resistance in the upper body [Raup(t)]. B: cardiac contractility of the left ventricle [clv(t)]. C: compliance of veins in the upper body [cvu(t)]. Results were obtained by solving Eq. 13 together with equations for the cardiovascular system (Eq. 2). Autonomic regulation yields increase in peripheral resistance, cardiac contractility, and vascular tone. The latter yields a decrease in compliance as shown. Timing of the different controls varies; especially, note that cardiac contractility changes faster than resistances and capacitances. Regulation of the remaining resistances, contractility, and compliances showed similar responses.
CONCLUSION
In summary, we have developed an 11-compartment model that can predict cerebral blood flow velocity and finger blood pressure. This model includes a physiological description of dynamics as a response to hydrostatic pressure changes during postural change from sitting to standing. Furthermore, our model includes nonlinear functions describing resistances of the large systemic arteries as functions of pressure. To regulate blood pressure and cerebral blood flow velocity after postural change from sitting to standing, our model includes autonomic regulation using first-order differential equations regulating cardiac contractility, peripheral resistance, and vascular tone (compliance). Furthermore, we have included an empirical model describing the dynamics of cerebral vascular resistance. Validation of our model against one data set showed that, by including the mechanisms described above, our model is able to reproduce the dynamics of blood flow velocity and blood pressure needed to compensate for hypotension observed during postural change from sitting to standing.
Modeling of physiological responses to standing enables a better understanding of physiological mechanisms underlying disorders related to orthostatic tolerance, e.g., orthostatic hypotension and syncope. Our model predicts that, in the absence of regulatory mechanisms (Fig. 8), blood pressure and blood flow velocity declined on the transition to standing and did not recover to baseline in the upright position. This modeling result has not been validated against data. However, similar responses have been observed clinically. For example, sustained blood pressure reduction in the upright position is seen in clinical syndromes with orthostatic hypotension associated with autonomic failure (16, 17). Different etiologies and severity of autonomic failure may lead to differences in patho-physiological responses during the transition to standing. For example, severe peripheral autonomic failure, such as pure autonomic failure or diabetic neuropathy, may be associated with orthostatic hypotension with no heart rate increment. Cerebral autoregulation, which maintains cerebral perfusion over a wide range of pressure (25), may be preserved, expanded, or reduced in orthostatic hypotension. However, cerebral blood flow would decline with impairment of autoregulation and/or when blood pressure is diminished below the autoregulated range. A transient impairment of autonomic and cerebral blood flow control is common in young people with vasodepressor syncope. This is associated with a withdrawal of sympathetic tone followed by a decline of blood pressure and cerebral perfusion (12, 22, 24).
Furthermore, our results show that, by including passive nonlinear responses of resistances in the large arteries, we can obtain sufficient widening of the pulse pressure amplitude observed immediately after the transition to standing. This response is immediate and, thus, not a regulatory response but, rather, a purely passive response that occurs because of the nature of the underlying fluid dynamics. We have described an elaborate model for predicting effects of hydrostatic changes, even though this model was only validated for the transition from sitting to standing, i.e., cos(ψ) = 1. The advantage of the model derived in the present work is that it may be applicable to prediction of hydrostatic effects observed during tilt-table experiments.
The main accomplishment of this work is that our model describes how autonomic regulation and cerebral autoregulation play a synergistic role in the control of arterial blood pressure and cerebral blood flow velocity. In particular, the cerebral resistance first decreases and then increases during active standing. This result is different from previous findings (27), which suggested an initial increase followed by a decrease. However, the new result is not surprising, because the present study was performed with a more complex closed-loop model. The main advantage of the closed-loop 11-compartment model presented in this study is that the cerebrovascular resistance offers a more accurate representation of the brain. For example, in previous work (27), the measured pressure was an input and only one compartment was included. Hence, the peripheral resistance was not distinguished between resistance of the body and the brain. Furthermore, the curve for Racp displays hysteresis effects: Immediately after standing, the decrease of Racp is faster than the increase for t≤ 70 s during the phase where blood flow velocity is returning to its normal value. Hysteresis in vascular resistance in response to decreasing and increasing pressures may reflect differences between cerebral and peripheral vasculature that account for time lags between central and peripheral responses. With normal auto-regulation, blood flow velocity precedes changes in peripheral blood pressure, reflecting local adjustments to intracranial pressure (26). Finally, to obtain a blood flow velocity during standing that is equivalent to that during sitting, the resistance reaches a set point that is higher during standing than during sitting.
Results for parameters representative of autonomic regulation show that these parameters react as expected: peripheral resistance and cardiac contractility increase, while compliance decreases (Fig. 10). As described in RESULTS, the contractility increases much faster than the peripheral resistance. This could be due to the more rapid effects of parasympathetic withdrawal acting on contractility than of sympathetic activation, which has a later effect on contractility, peripheral resistance, and compliance.
Finally, the optimized parameters depend on the initial estimates and the optimization algorithm. In particular, some of the maximum values for the resistances and compliances have large values, which are physiologically unrealistic.
ACKNOWLEDGMENTS
This work was supported by US-Austria-Denmark Cooperative Research: Modeling and Control of the Cardiovascular-Respiratory System Grant 0437037 from the National Science Foundation. Work performed at Beth Israel Deaconess Medical Center General Clinical Research Center was supported by National Institutes of Health Grants M01 RR-01302, R01 NS-045745-01A2, and P60 AG-08812. L. Ellwein was supported by predoctoral National Research Service Award Training Grant TR32-AG-023480 and a Statistical and Applied Mathematical Sciences Institute graduate fellowship. Data collection and analysis were supported by a Joseph Paresky Men’s Associates grant from the Hebrew Rehabilitation Center for Aged, National Institute on Aging Research Nursing Home Grant AG-04390, and Alzheimers Disease Research Center Grant AG-05134. H. Tran was supported in part by National Institute of General Medical Sciences Grant RO1 GM-067299-03.
Glossary
- A
Cross-sectional area
- a
Aorta
- ac
Cerebral arteries (in the brain)
- acp
Peripheral cerebral arteries
- af
Finger arteries
- afp
Peripheral finger arteries
- al
Arteries in the lower body
- alp
Peripheral arteries in the lower body
- au
Arteries in the upper body
- aup
Peripheral arteries in the upper body
- av
Aortic valve
- C
Compliance
- c
Contractility
- fact
Constant factor (area of vessel)
- g
Gravitational acceleration
- H
Heart rate
- h
Height
- k
Constant (steepness of sigmoid)
- L
Inertance
- l
Length
- la
Left atrium
- lv
Left ventricle
- M
Maximum
- m
Minimum
- mv
Mitral valve
- p
Blood pressure
- pin
Pressure at inlet
- pout
Pressure at outlet
- pp
Peak value of activation
- q
Volumetric flow rate
- R
Resistance to flow
- r
Radius
- T
Duration of the cardiac cycle
- tp
Peak value of contraction
- V
Stressed volume
- v
Velocity
- v
Vena cava
- vc
Cerebral veins
- vl
Veins in the lower body
- Vstroke
Stroke volume
- vu
Veins in the trunk and upper body
- η
Viscosity
- ν
Steepness
- ρ
Density of fluid
- τ
Time constant
APPENDIX
The complete system of differential equations needed to describe all flows and pressures shown in Fig. 1 consists of 11 ordinary differential equations. For each of the nine compartments that represent the arteries and veins, we obtain differential equations of the form of Eq. 2
where each of the flows is determined using Kirchhoff’s current law. The flows are as follows
Finally, differential equations for the two compartments that represent the left atrium and ventricle are given by
For these compartments, pressures are computed using the heart model (see MODELING BLOOD PRESSURE AND BLOOD FLOW VELOCITY. Ventricular and atrial contraction).
REFERENCES
- 1.Aaslid R, Markwalder TM, Nornes H. Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg. 1982;57:769–774. doi: 10.3171/jns.1982.57.6.0769. [DOI] [PubMed] [Google Scholar]
- 2.Aaslid R. Cerebral hemodynamics. In: Newell DW, Aaslid R, editors. Transcranial Doppler. Raven; New York: 1992. pp. 49–55. [Google Scholar]
- 3.Beneken JEW, DeWit B. A physical approach to hemodynamic aspects of the human cardiovascular system. In: Guyton AC, Reeve EB, editors. Physical Basis of Circulatory Transport: Regulation and Exchange. Saunders; Philadelphia, PA: 1966. pp. 1–45. [Google Scholar]
- 4.Bullock J, Boyle J, Wang M. Physiology. 4th ed. Lippincott Williams & Wilkins; Philadelphia, PA: 2001. [Google Scholar]
- 5.Danielsen M. Modeling of Feedback Mechanisms Which Control the Heart Function in a View to An Implementation in Cardiovascular Models. Roskilde University; Roskilde, Denmark: 1998. PhD thesis. [Google Scholar]
- 6.Danielsen M, Ottesen JT. Describing the pumping heart as a pressure source. J Theor Biol. 2001;212:71–81. doi: 10.1006/jtbi.2001.2348. [DOI] [PubMed] [Google Scholar]
- 7.Guyton AC, Hall JE. Textbook of Medical Physiology. 9th ed. Saunders; Philadelphia, PA: 1996. [Google Scholar]
- 8.Heldt T, Shim EB, Kamm RD, Mark RD. Computational modeling of cardiovascular response to orthostatic stress. J Appl Physiol. 2002;92:1239–1254. doi: 10.1152/japplphysiol.00241.2001. [DOI] [PubMed] [Google Scholar]
- 9.Kappel F, Peer RO. A mathematical model for fundamental regulation processes in the cardiovascular system. J Math Biol. 1993;31:611–631. doi: 10.1007/BF00161201. [DOI] [PubMed] [Google Scholar]
- 10.Kappel F, Lafer A, Peer RO. A model for the cardiovascular system under an ergometric workload. Surv Math Ind. 1997;7:239–250. [Google Scholar]
- 11.Kappel F, Batzel JJ. Survey of research in modeling the human respiratory and cardiovascular systems. In: Smith RC, Demetriou MA, editors. Research Directions in Distributed Parameter Systems. SIAM; Philadelphia, PA: 2003. pp. 187–218. [Google Scholar]
- 12.Kaufmann H. Syncope. A neurologist’s viewpoint. Cardiol Clin. 1997;15:177–194. doi: 10.1016/s0733-8651(05)70329-5. [DOI] [PubMed] [Google Scholar]
- 13.Kelley C. Iterative Methods for Optimization. SIAM; Philadelphia, PA: 1999. [Google Scholar]
- 14.Landau LD, Lifshitz EM. Fluid Mechanics. 2nd ed. Pergamon; Oxford, UK: 1993. p. 57. [Google Scholar]
- 15.Lipsitz LA, Mukai S, Hamner J, Gagnon M, Babikian V. Dynamic regulation of middle cerebral artery blood flow velocity in aging and hypertension. Stroke. 2000;31:1897–1903. doi: 10.1161/01.str.31.8.1897. [DOI] [PubMed] [Google Scholar]
- 16.Low PA. Autonomic nervous system function. J Clin Neurophysiol. 1993;10:14–27. doi: 10.1097/00004691-199301000-00003. [DOI] [PubMed] [Google Scholar]
- 17.Low PA, Bannister RG. Multiple system atrophy and pure autonomic failure. In: Low PA, editor. Clinical Autonomic Disorders. Lippincott-Raven; Philadelphia, PA: 1997. pp. 555–575. [Google Scholar]
- 18.Low PA, Novak V, Spies JM, Petty G. Cerebrovascular regulation in the postural tachycardia syndrome (POTS) Am J Med Sci. 1999;317:124–133. doi: 10.1097/00000441-199902000-00007. [DOI] [PubMed] [Google Scholar]
- 19.Melchior FM, Scrinivasen RS, Charles JB. Mathematical modeling of the human response to LBNP. Physiologist. 1992;35(Suppl 1):S204–S205. [PubMed] [Google Scholar]
- 20.Melchior FM, Scrinivasen RS, Clere JM. Simulation of cardiovascular response to lower body negative pressure from 0 mmHg to -40 mmHg. J Appl Physiol. 1994;77:630–640. doi: 10.1152/jappl.1994.77.2.630. [DOI] [PubMed] [Google Scholar]
- 21.Neumann S. Modeling Acute Hemorrhage in the Human Cardiovascular System. University of Pennsylvania; Philadelphia, PA: 1996. PhD thesis. [Google Scholar]
- 22.Njemanze PC. Cerebral circulation dysfunction and hemodynamic abnormalities in syncope during upright tilt test. Can J Cardiol. 1993;9:238–242. [PubMed] [Google Scholar]
- 23.Noordergraaf A. Circulatory System Dynamics. Academic; New York: 1978. p. 24. [Google Scholar]
- 24.Novak V, Honos G, Schondorf R. Is the heart “empty” at syncope? J Auton Nerv Syst. 1996;60:83–92. doi: 10.1016/0165-1838(96)00040-9. [DOI] [PubMed] [Google Scholar]
- 25.Novak V, Novak P, Spies JM, Low PA. The autoregulation of cerebral blood flow in orthostatic hypotension. Stroke. 1998;29:104–111. doi: 10.1161/01.str.29.1.104. [DOI] [PubMed] [Google Scholar]
- 26.Novak V, Yang ACC, Lepicovsky L, Goldbeger AL, Lipsitz LA, Peng CK. Multimodal pressure-flow method to assess dynamics of cerebral autoregulation in stroke and hypertension. BioMed Eng Online. 2004;3:39. doi: 10.1186/1475-925X-3-39. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Olufsen MS, Nadim A, Lipsitz LA. Dynamics of cerebral blood flow regulation explained using a lumped parameter model. Am J Physiol Regul Integr Comp Physiol. 2002;282:R611–R622. doi: 10.1152/ajpregu.00285.2001. [DOI] [PubMed] [Google Scholar]
- 28.Olufsen MS, Nadim A. On deriving lumped models for blood flow and pressure in the systemic arteries. Math Biosci Eng. 2004;1:61–80. doi: 10.3934/mbe.2004.1.61. [DOI] [PubMed] [Google Scholar]
- 29.Olufsen MS, Tran A, Ottesen JT. Modeling cerebral blood flow control during posture change from sitting to standing. Cardiovasc Eng. 2004;4:47–58. [Google Scholar]
- 30.Ono K, Uozumi T, Yoshimoto C, Kenner T. The optimal cardiovascular regulation of the arterial blood pressure. In: Kenner T, Busse R, Hinghofer-Szalkay H, editors. Cardiovascular System Dynamics: Model and Measurements. Plenum; New York: 1982. pp. 119–139. [Google Scholar]
- 31.Ottesen JT. Modeling of the baroreflex-feedback mechanism with time-delay. J Math Biol. 1997;36:41–63. doi: 10.1007/s002850050089. [DOI] [PubMed] [Google Scholar]
- 32.Ottesen JT. Nonlinearity of baroreceptor nerves. Surv Math Ind. 1997;7:187–201. [Google Scholar]
- 33.Ottesen JT, Danielsen M. Modeling ventricular contraction with heart rate changes. J Theor Biol. 2003;222:337–346. doi: 10.1016/s0022-5193(03)00040-7. [DOI] [PubMed] [Google Scholar]
- 34.Panerai RB. Assessment of cerebral pressure autoregulation in humans—a review of measurement methods. Physiol Meas. 1998;19:305–338. doi: 10.1088/0967-3334/19/3/001. [DOI] [PubMed] [Google Scholar]
- 35.Rideout V. Mathematical and Computer Modeling of Physiological Systems. Medical Physics Publishing; Englewood Cliffs, NJ: 1991. [Google Scholar]
- 36.Serrador JM, Picot PA, Rutt BK, Shoemaker JK, Bondar RL. MRI measures of middle cerebral artery diameter in conscious humans during simulated orthostasis. Stroke. 2000;31:1672–1678. doi: 10.1161/01.str.31.7.1672. [DOI] [PubMed] [Google Scholar]
- 37.Smith JJ, Kampine JT. Circulatory Physiology, the Essentials. 3rd ed. Williams & Wilkins; Baltimore, MD: 1990. [Google Scholar]
- 38.Tiecks FP, Lam AM, Aaslid R, Newell DW. Comparison of static and dynamic cerebral autoregulation measurements. Stroke. 1995;26:1014–1019. doi: 10.1161/01.str.26.6.1014. [DOI] [PubMed] [Google Scholar]
- 39.Ursino M, Lodi CA. Interaction among autoregulation, CO2 reactivity, and intercranial pressure: a mathematical model. Am J Physiol Heart Circ Physiol. 1998;274:H1715–H1728. doi: 10.1152/ajpheart.1998.274.5.H1715. [DOI] [PubMed] [Google Scholar]
- 40.Ursino M. Interaction between carotid baroregulation and the pulsating heart: a mathematical model. Am J Physiol Heart Circ Physiol. 1998;275:H1733–H1747. doi: 10.1152/ajpheart.1998.275.5.H1733. [DOI] [PubMed] [Google Scholar]
- 41.Warner HR. The frequency-dependent nature of blood pressure regulation by carotid sinus studied with an electric analog. Circ Res. 1958;6:35–40. doi: 10.1161/01.res.6.1.35. [DOI] [PubMed] [Google Scholar]
- 42.Warner HR. Use of analogue computers in the study of control mechanisms in the circulation. Fed Proc. 1962;21 [PubMed] [Google Scholar]
- 43.Warner HR, Cox A. A mathematical model of heart rate control by sympathetic and vagus efferent information. J Appl Physiol. 1962;17:349–358. doi: 10.1152/jappl.1962.17.2.349. [DOI] [PubMed] [Google Scholar]
- 44.Wesseling KH, Stettels JJ, Walstra G, Van Esch HJ, Donders JH. Baromodulation as the cause of short-term blood pressure variability. In: Alberi G, Bajzer Z, Baxa P, editors. Application of Physics to Medicine and Biology. World Scientific; Singapore: 1982. pp. 247–276. [Google Scholar]