Self-disinfecting plastics for intravenous catheters and prosthetic inserts.

D Kingston, D V Seal, I D Hill
PMCID: PMC2129647  PMID: 3517154

Abstract

A disinfectant (2,4,4'-trichloro-2'-hydroxydiphenyl ether: Irgasan, Ciba-Geigy) was incorporated into plastic washers fabricated from ethylvinyl acetate (EVA), polyethylene, polypropylene or TPX. Plastics containing 0.2 and 2% Irgasan gave zones of inhibition on nutrient and blood agar plates seeded with micro-organisms (Staphylococcus aureus, Staph. epidermidis, Escherichia coli, Proteus mirabilis or Candida albicans) even after thorough washing. Exceptionally, C. albicans was inhibited only by 2% Irgasan, and EVA gave good inhibition only against the staphylococci. Similar washers of each plastic were implanted subcutaneously into the flanks of rabbits; before insertion each was washed, had thread woven into it and was surrounded by a plasma clot containing 2 X 10(8) Staph. aureus. All the plastics without Irgasan gave rise to abscesses, none of the plastics impregnated with 2% Irgasan did, though from 2 out of 12 sites small numbers of Staph. aureus were isolated at post mortem. Using either clinical or bacteriological criteria, the results were highly significant (P less than 0.00001 and P less than 0.001 respectively), demonstrating the effectiveness of this technique in preventing plastic-associated infection.

Full text

PDF
185

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Chalkley T., Sarnat L., Shoch D. Evaluation of "bacteriostatic" contact lenses. A double-blind study. Am J Ophthalmol. 1966 May;61(5 Pt 1):866–869. [PubMed] [Google Scholar]
  2. ELEK S. D., CONEN P. E. The virulence of Staphylococcus pyogenes for man; a study of the problems of wound infection. Br J Exp Pathol. 1957 Dec;38(6):573–586. [PMC free article] [PubMed] [Google Scholar]
  3. KINGSTON D., NOBLE W. C. TESTS ON SELF-DISINFECTING SURFACES. J Hyg (Lond) 1964 Dec;62:519–531. doi: 10.1017/s0022172400040237. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. MILLER J. M., GINSBERG M., McELFATRICK G. C., SMITH L. B., BOGOSIAN A. Use of a plastic film containing an antimicrobial substance as a dressing for wounds. Md State Med J. 1962 Mar;11:126–127. [PubMed] [Google Scholar]
  5. Price E. H. Staphylococcus epidermidis infections of cerebrospinal fluid shunts. J Hosp Infect. 1984 Mar;5(1):7–17. doi: 10.1016/0195-6701(84)90096-3. [DOI] [PubMed] [Google Scholar]
  6. Taylor G. F. Survival of gram-negative bacteria on plastic compounded with hexachlorophene. Appl Microbiol. 1970 Jan;19(1):131–133. doi: 10.1128/am.19.1.131-133.1970. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Towers A. G., Stinson N. E. The effect of an antimicrobial coating on metal implants. A pilot study in goats. Acta Orthop Scand. 1966;37(2):211–218. doi: 10.3109/17453676608993280. [DOI] [PubMed] [Google Scholar]
  8. Whyte W., Hodgson R., Tinkler J., Graham J. The isolation of bacteria of low pathogenicity from faulty orthopaedic implants. J Hosp Infect. 1981 Sep;2(3):219–230. doi: 10.1016/0195-6701(81)90041-4. [DOI] [PubMed] [Google Scholar]

Articles from The Journal of Hygiene are provided here courtesy of Cambridge University Press

RESOURCES