Abstract
Experiments were conducted simultaneously with gas and particle tracers to determine the relative loss of particles between source and recipient sites in the hospital ward units. The magnitude of this loss could be accounted for by the assumption of sedimentation from well-mixed air masses during the time required for movement between source and recipients sites. As a consequence of this loss the degree of isolation between patient rooms for airborne particles was between 4 and 25 times greater than that for gaseous contamination, which reflects the actual transport of air between the rooms. The design and construction of portable spinning-disk particle generators suitable for field studies is discussed.
Full text
PDF













Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Foord N., Lidwell O. M. Airborne infection in a fully air-conditioned hospital. I. Air transfer between rooms. J Hyg (Lond) 1975 Aug;75(1):15–30. doi: 10.1017/s0022172400047033. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Foord N., Lidwell O. M. The control by ventilation of airborne bacterial transfer between hospital patients, and its assessment by means of a particle tracer. I. An airborne-particle tracer for cross-infection studies. J Hyg (Lond) 1972 Jun;70(2):279–286. doi: 10.1017/s0022172400022336. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hambraeus A., Sanderson H. F. The control by ventilation of airborne bacterial transfer between hospital patients, and its assessment by means of a particle tracer. 3. Studies with an airborne-particle tracer in an isolation ward for burned patients. J Hyg (Lond) 1972 Jun;70(2):299–312. doi: 10.1017/s002217240002235x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- LIDWELL O. M. The evaluation of ventilation. J Hyg (Lond) 1960 Sep;58:297–305. doi: 10.1017/s0022172400038419. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lidwell O. M. Airborne infection in a fully air-conditioned hospital. II. Transport of gaseous and airborne particulate material along ventilated passageways. J Hyg (Lond) 1975 Aug;75(1):45–56. doi: 10.1017/s0022172400047057. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lippmann M., Albert R. E. A compact electric-motor driven spinning disc aerosol generator. Am Ind Hyg Assoc J. 1967 Nov-Dec;28(6):501–506. doi: 10.1080/00028896709342675. [DOI] [PubMed] [Google Scholar]
- NOBLE W. C., LIDWELL O. M., KINGSTON D. THE SIZE DISTRIBUTION OF AIRBORNE PARTICLES CARRYING MICRO-ORGANISMS. J Hyg (Lond) 1963 Dec;61:385–391. doi: 10.1017/s0022172400020994. [DOI] [PMC free article] [PubMed] [Google Scholar]