Abstract
The viability of pneumococcus, Type I, sprayed into the atmosphere from a liquid suspension was measured as a function of the relative humidity. When broth, saliva, or 0.5 per cent saline solution is employed as the suspending medium, a very high mortality rate is observed at relative humidities in the vicinity of 50 per cent. However, at humidities above or below this value the microorganisms survive for long periods. Measurement of the rate of settling of droplets employed in these experiments demonstrated that the disappearance of microorganisms from the air is a true lethal process, rather than a manifestation of aerosol collision processes. When a saline-free fluid was used, the sharp peak in death rate at intermediate relative humidities disappears. The lethal effect of intermediate relative humidities on pneumococci atomized from a saline-containing suspension is increased when the particle size of the atomized droplets is increased or when the temperature is raised. Cultures of hemolytic streptococcus group C and staphylococcus sprayed from a broth medium exhibit the same general survival pattern as a function of relative humidity although the mortality rates are smaller than that of the pneumococcus. These effects can be explained by assuming the existence of a critical degree of cellular dehydration at which microorganisms become much more sensitive to toxic agents than in states where either more or less water is bound to the cell. The results presented here may be significant in elucidating certain aspects of the epidemiology of air-borne infections.
Full Text
The Full Text of this article is available as a PDF (812.4 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Puck T. T., Robertson O. H., Lemon H. M. THE BACTERICIDAL ACTION OF PROPYLENE GLYCOL VAPOR ON MICROORGANISMS SUSPENDED IN AIR : II. THE INFLUENCE OF VARIOUS FACTORS ON THE ACTIVITY OF THE VAPOR. J Exp Med. 1943 Nov 1;78(5):387–406. doi: 10.1084/jem.78.5.387. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Puck T. T. THE MECHANISM OF AERIAL DISINFECTION BY GLYCOLS AND OTHER CHEMICAL AGENTS : I. DEMONSTRATION THAT THE GERMICIDAL ACTION OCCURS THROUGH THE AGENCY OF THE VAPOR PHASE. J Exp Med. 1947 May 31;85(6):729–739. doi: 10.1084/jem.85.6.729. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Robertson O. H., Puck T. T., Wise H. THE CONSTRUCTION AND OPERATION OF EXPERIMENTAL ROOMS FOR THE STUDY OF AIR-BORNE INFECTION. J Exp Med. 1946 Nov 30;84(6):559–567. doi: 10.1084/jem.84.6.559. [DOI] [PMC free article] [PubMed] [Google Scholar]