Skip to main content
Anesthesia Progress logoLink to Anesthesia Progress
. 1997 Winter;44(1):23–26.

Is measurement of end-tidal CO2 through a nasal cannula reliable?

K Fukuda 1, T Ichinohe 1, Y Kaneko 1
PMCID: PMC2148854  PMID: 9481977

Abstract

When using a nasal cannula to sample gases expired by a patient, air from the room may dilute the sample. For this reason, the accuracy of the partial pressure of end-tidal carbon dioxide (ETCO2) measurements is questionable. We experimentally examined the reliability of ETCO2 measurements through a nasal cannula and found that they depended on both biological factors (tidal volume and respiratory rates) and mechanical factors (the diameter and the length of the cannula and the diameter of the prongs). These results suggest that the correct use of an appropriate sampling cannula will provide reliable ETCO2 measurements without clinical problems.

Full text

PDF
23

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Ackerman W. E., Phero J. C., Reaume D. End tidal carbon dioxide and respiratory rate measurement during conscious sedation through a nasal cannula. Anesth Prog. 1990 Jul;37(4):199–200. [PMC free article] [PubMed] [Google Scholar]
  2. Anderson J. A. Respiratory monitoring for anesthesia and sedation. Anesth Prog. 1987 Nov-Dec;34(6):228–231. [PMC free article] [PubMed] [Google Scholar]
  3. Badgwell J. M., Kleinman S. E., Heavner J. E. Respiratory frequency and artifact affect the capnographic baseline in infants. Anesth Analg. 1993 Oct;77(4):708–712. doi: 10.1213/00000539-199310000-00009. [DOI] [PubMed] [Google Scholar]
  4. Badgwell J. M., McLeod M. E., Lerman J., Creighton R. E. End-tidal PCO2 measurements sampled at the distal and proximal ends of the endotracheal tube in infants and children. Anesth Analg. 1987 Oct;66(10):959–964. [PubMed] [Google Scholar]
  5. Derrick S. J., Waters H., Kang S. W., Cwalina T. F., Simmons W. Evaluation of a nasal/oral discriminate sampling system for capnographic respiratory monitoring. AANA J. 1993 Oct;61(5):509–520. [PubMed] [Google Scholar]
  6. Forster A., Morel D., Bachmann M., Gemperle M. Respiratory depressant effects of different doses of midazolam and lack of reversal with naloxone--a double-blind randomized study. Anesth Analg. 1983 Oct;62(10):920–924. [PubMed] [Google Scholar]
  7. Hunter J. A. A cost-free, simple method for monitoring end tidal carbon dioxide through nasal cannulae. Anesth Prog. 1990 Nov-Dec;37(6):301–303. [PMC free article] [PubMed] [Google Scholar]
  8. Ibarra E., Lees D. E. Mass spectrometer monitoring of patients with regional anesthesia. Anesthesiology. 1985 Nov;63(5):572–573. doi: 10.1097/00000542-198511000-00035. [DOI] [PubMed] [Google Scholar]
  9. Kaneko Y. Clinical perspectives on capnography during sedation and general anesthesia in dentistry. Anesth Prog. 1995;42(3-4):126–130. [PMC free article] [PubMed] [Google Scholar]
  10. Schena J., Thompson J., Crone R. K. Mechanical influences on the capnogram. Crit Care Med. 1984 Aug;12(8):672–674. doi: 10.1097/00003246-198408000-00015. [DOI] [PubMed] [Google Scholar]

Articles from Anesthesia Progress are provided here courtesy of American Dental Society of Anesthesiology

RESOURCES