Abstract
This paper deals with the use of fuzzy logic and dynamic programming in the detection of cardiac contours in MR Images. The definition of two parameters for each pixel allows the construction of the fuzzy set of the cardiac contour points. The first parameter takes into account the grey level, and the second the presence of an edge. A corresponding fuzzy matrix is derived from the initial image. Finally, a dynamic programming with graph searching is performed on this fuzzy matrix. The method has been tested on several MR images and the results of the contouring were validated by an expert in the domain. This preliminary work clearly demonstrates the interest of this method, although a formal evaluation has to be done.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Feng J., Lin W. C., Chen C. T. Epicardial boundary detection using fuzzy reasoning. IEEE Trans Med Imaging. 1991;10(2):187–199. doi: 10.1109/42.79477. [DOI] [PubMed] [Google Scholar]
- Fleagle S. R., Thedens D. R., Ehrhardt J. C., Scholz T. D., Skorton D. J. Automated identification of left ventricular borders from spin-echo magnetic resonance images. Experimental and clinical feasibility studies. Invest Radiol. 1991 Apr;26(4):295–303. doi: 10.1097/00004424-199104000-00002. [DOI] [PubMed] [Google Scholar]
- Goshtasby A., Turner D. A. Segmentation of cardiac cine MR images for extraction of right and left ventricular chambers. IEEE Trans Med Imaging. 1995;14(1):56–64. doi: 10.1109/42.370402. [DOI] [PubMed] [Google Scholar]
- Kirsch R. A. Computer determination of the constituent structure of biological images. Comput Biomed Res. 1971 Jun;4(3):315–328. doi: 10.1016/0010-4809(71)90034-6. [DOI] [PubMed] [Google Scholar]
- Lobregt S., Viergever M. A. A discrete dynamic contour model. IEEE Trans Med Imaging. 1995;14(1):12–24. doi: 10.1109/42.370398. [DOI] [PubMed] [Google Scholar]
- Marr D., Hildreth E. Theory of edge detection. Proc R Soc Lond B Biol Sci. 1980 Feb 29;207(1167):187–217. doi: 10.1098/rspb.1980.0020. [DOI] [PubMed] [Google Scholar]
- Pattynama P. M., Lamb H. J., van der Velde E. A., van der Wall E. E., de Roos A. Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis. Radiology. 1993 Apr;187(1):261–268. doi: 10.1148/radiology.187.1.8451425. [DOI] [PubMed] [Google Scholar]
- Pope D. L., Parker D. L., Clayton P. D., Gustafson D. E. Left ventricular border recognition using a dynamic search algorithm. Radiology. 1985 May;155(2):513–518. doi: 10.1148/radiology.155.2.3885315. [DOI] [PubMed] [Google Scholar]
- Thedens D. R., Skorton D. J., Fleagle S. R. Methods of graph searching for border detection in image sequences with applications to cardiac magnetic resonance imaging. IEEE Trans Med Imaging. 1995;14(1):42–55. doi: 10.1109/42.370401. [DOI] [PubMed] [Google Scholar]