Physiologic Trend Detection and Artifact Rejection: A Parallel Implementation of a Multi-state Kalman Filtering Algorithm

Dean F Sittig, Michael Factor
PMCID: PMC2245677

Abstract

Using a parallel implementation of the multi-state Kalman filtering algorithm, we have developed an accurate method of reliably detecting and identifying trends, abrupt changes, and artifacts from multiple physiologic data streams in real-time. The Kalman filter algorithm was implemented within an innovative software architecture for parallel computation: a parallel process trellis. Examples, processed in real-time, of both simulated and actual data serve to illustrate the potential value of the Kalman filter as a tool in physiologic monitoring.

Full text

PDF
569

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Avent R. K., Charlton J. D., Nagle H. T., Johnson R. N. A Monte Carlo technique for signal level detection in implanted intracranial pressure monitoring. Ann Biomed Eng. 1987;15(1):79–89. doi: 10.1007/BF02364169. [DOI] [PubMed] [Google Scholar]
  2. Gravenstein J. S., de Vries A., Beneken J. E. Sampling intervals for clinical monitoring of variables during anesthesia. J Clin Monit. 1989 Jan;5(1):17–21. doi: 10.1007/BF01618365. [DOI] [PubMed] [Google Scholar]
  3. Gustafson D. E., Willsky A. S., Wang J. Y., Lancaster M. C., Triebwasser J. H. ECG/VCG rhythm diagnosis using statistical signal analysis--I. Identification of persistent rhythms. IEEE Trans Biomed Eng. 1978 Jul;25(4):344–353. doi: 10.1109/tbme.1978.326260. [DOI] [PubMed] [Google Scholar]
  4. Hope C. E., Lewis C. D., Perry I. R., Gamble A. Computed trend analysis in automated patient monitoring systems. Br J Anaesth. 1973 May;45(5):440–449. doi: 10.1093/bja/45.5.440. [DOI] [PubMed] [Google Scholar]
  5. Shabot M. M., LoBue M., Leyerle B. J. An automatic PDMS interface for the Urotrack Plus 220 urimeter. Int J Clin Monit Comput. 1988;5(2):125–131. doi: 10.1007/BF02919654. [DOI] [PubMed] [Google Scholar]
  6. Smith A. F., West M. Monitoring renal transplants: an application of the multiprocess Kalman filter. Biometrics. 1983 Dec;39(4):867–878. [PubMed] [Google Scholar]
  7. Smith S. R., Wheeler B. C. A real-time multiprocessor system for acquisition of multichannel neural data. IEEE Trans Biomed Eng. 1988 Oct;35(10):875–877. doi: 10.1109/10.7295. [DOI] [PubMed] [Google Scholar]
  8. Trimble I. M., West M., Knapp M. S., Pownall R., Smith A. F. Detection of renal allograft rejection by computer. Br Med J (Clin Res Ed) 1983 May 28;286(6379):1695–1699. doi: 10.1136/bmj.286.6379.1695. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. von Spreckelsen M., Bromm B. Estimation of single-evoked cerebral potentials by means of parametric modeling and Kalman filtering. IEEE Trans Biomed Eng. 1988 Sep;35(9):691–700. doi: 10.1109/10.7270. [DOI] [PubMed] [Google Scholar]

Articles from Proceedings of the Annual Symposium on Computer Application in Medical Care are provided here courtesy of American Medical Informatics Association

RESOURCES