Probabilistic constraint satisfaction: application to radiosurgery.

R B Altman 1, R Tombropoulos 1
PMCID: PMC2247759  PMID: 7950031

Abstract

Although quite successful in a variety of settings, standard optimization approaches can have drawbacks within medical applications. For example, they often provide a single solution which is difficult to explain, or which can not be incrementally modified using secondary "soft" constrains that are difficult to encode within the optimization. In order to address these issues, we have developed a probabilistic optimization technique that allows the user to enter prior probability distributions (Gaussian) for the parameters to be optimized as well as for the constraints on the parameters. Our technique combines the prior distributions with the constraints using Bayes' rule. The algorithm produces not only a set of parameter values, but variances on these values and covariances showing the correlations between parameters. We have applied this method to the problem of planning a radiosurgical ablation of brain tumors. The radiation plan should maximize dose to tumor, minimize dose to surrounding areas, and provide an even distribution of dosage across the tumor. It also should be explainable to and modifiable by the expert physicians based on external considerations. We have compared the results of our method with the standard linear programming approach.

Full text

PDF
780

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Betti O. O., Munari C., Rosler R. Stereotactic radiosurgery with the linear accelerator: treatment of arteriovenous malformations. Neurosurgery. 1989 Mar;24(3):311–321. doi: 10.1227/00006123-198903000-00001. [DOI] [PubMed] [Google Scholar]
  2. Brahme A. Optimization of stationary and moving beam radiation therapy techniques. Radiother Oncol. 1988 Jun;12(2):129–140. doi: 10.1016/0167-8140(88)90167-3. [DOI] [PubMed] [Google Scholar]
  3. LARSSON B., LEKSELL L., REXED B., SOURANDER P., MAIR W., ANDERSSON B. The high-energy proton beam as a neurosurgical tool. Nature. 1958 Nov 1;182(4644):1222–1223. doi: 10.1038/1821222a0. [DOI] [PubMed] [Google Scholar]

Articles from Proceedings of the Annual Symposium on Computer Application in Medical Care are provided here courtesy of American Medical Informatics Association

RESOURCES