Abstract
A quality assurance program has been established by the European Group for Rapid Viral Diagnosis and the European Expert Group on Viral Hepatitis for monitoring nucleic acid detection methods for hepatitis B virus (HBV) DNA in serum samples. Thirty-nine laboratories participated in this quality program and generated 43 data sets. Of the participating laboratories, all but one used the PCR technique to detect HBV DNA. A coded panel was tested that was composed of seven undiluted HBV DNA-positive serum samples and five HBV DNA-negative donor serum samples. Furthermore, two dilution series, one from a positive patient and one from a full-length recombinant DNA, were included. Twenty-six data sets (60.5%) had faultless results with both dilution series. Twelve data sets (27.9%) recognized the undiluted serum samples, and 19 data sets (44.2%) had false-negative and/or false-positive results. Ten data sets (23.3%) performed well with the entire panel of samples. From these results, it can be concluded that in a large group of laboratories HBV detection by PCR shows specificity and sensitivity problems; therefore, PCR test interpretation should be done with great care.
Full Text
The Full Text of this article is available as a PDF (274.4 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Boom R., Sol C. J., Salimans M. M., Jansen C. L., Wertheim-van Dillen P. M., van der Noordaa J. Rapid and simple method for purification of nucleic acids. J Clin Microbiol. 1990 Mar;28(3):495–503. doi: 10.1128/jcm.28.3.495-503.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bréchot C. Polymerase chain reaction for the diagnosis of viral hepatitis B and C. Gut. 1993;34(2 Suppl):S39–S44. doi: 10.1136/gut.34.2_suppl.s39. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Espy M. J., Smith T. F., Persing D. H. Dependence of polymerase chain reaction product inactivation protocols on amplicon length and sequence composition. J Clin Microbiol. 1993 Sep;31(9):2361–2365. doi: 10.1128/jcm.31.9.2361-2365.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Landegren U., Kaiser R., Caskey C. T., Hood L. DNA diagnostics--molecular techniques and automation. Science. 1988 Oct 14;242(4876):229–237. doi: 10.1126/science.3051381. [DOI] [PubMed] [Google Scholar]
- Longo M. C., Berninger M. S., Hartley J. L. Use of uracil DNA glycosylase to control carry-over contamination in polymerase chain reactions. Gene. 1990 Sep 1;93(1):125–128. doi: 10.1016/0378-1119(90)90145-h. [DOI] [PubMed] [Google Scholar]
- Noordhoek G. T., Kolk A. H., Bjune G., Catty D., Dale J. W., Fine P. E., Godfrey-Faussett P., Cho S. N., Shinnick T., Svenson S. B. Sensitivity and specificity of PCR for detection of Mycobacterium tuberculosis: a blind comparison study among seven laboratories. J Clin Microbiol. 1994 Feb;32(2):277–284. doi: 10.1128/jcm.32.2.277-284.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Udaykumar, Epstein J. S., Hewlett I. K. A novel method employing UNG to avoid carry-over contamination in RNA-PCR. Nucleic Acids Res. 1993 Aug 11;21(16):3917–3918. doi: 10.1093/nar/21.16.3917. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zaaijer H. L., Cuypers H. T., Reesink H. W., Winkel I. N., Gerken G., Lelie P. N. Reliability of polymerase chain reaction for detection of hepatitis C virus. Lancet. 1993 Mar 20;341(8847):722–724. doi: 10.1016/0140-6736(93)90488-3. [DOI] [PubMed] [Google Scholar]