Comparison of BioStar Strep A OIA optical immune assay, Abbott TestPack Plus Strep A, and culture with selective media for diagnosis of group A streptococcal pharyngitis.

M Roe 1, C Kishiyama 1, K Davidson 1, L Schaefer 1, J Todd 1
PMCID: PMC228213  PMID: 7650184

Abstract

We directly compared three techniques for the diagnosis of group A streptococcal pharyngitis in 500 symptomatic children seen in the Emergency Department or Child Care Clinic of The Children's Hospital of Denver. Throats were vigorously swabbed with two rayon swabs, which were transported immediately to the Microbiology Laboratory. Each swab was cultured aerobically on Strep A Isolation Agar (Remel) and then tested for antigen-one swab by the Strep A OIA optical immune assay (BioStar) and the other by the TestPack Plus Strep A (Abbott) technique. Each test was performed blind to the others. The refrigerated pledget was cultured in Todd-Hewitt broth if an antigen test was positive and both direct plate cultures were negative (the "gold standard" was any culture positive). All isolates were serologically grouped. Of 500 complete patient cultures, 151 (30%) were positive for group A streptococcal growth. The two antigen tests gave comparable results with an average sensitivity of 83%. Each was significantly (P < 0.02) less sensitive than its corresponding culture. The BioStar Strep A OIA optical immune assay produced significantly (P < 0.003) more false-positive results than did the Abbott test. Rapid antigen testing is not sensitive enough to eliminate the need for backup cultures.

Full Text

The Full Text of this article is available as a PDF (185.1 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bourbeau P. P., Heiter B. J., Anhalt J. P., Naumovitz D. W. Comparison of direct specimen testing utilizing TestPack strep A with testing of specimens following a two-hour broth enrichment. Diagn Microbiol Infect Dis. 1993 Aug-Sep;17(2):93–96. doi: 10.1016/0732-8893(93)90018-3. [DOI] [PubMed] [Google Scholar]
  2. Dale J. C., Vetter E. A., Contezac J. M., Iverson L. K., Wollan P. C., Cockerill F. R., 3rd Evaluation of two rapid antigen assays, BioStar Strep A OIA and Pacific Biotech CARDS O.S., and culture for detection of group A streptococci in throat swabs. J Clin Microbiol. 1994 Nov;32(11):2698–2701. doi: 10.1128/jcm.32.11.2698-2701.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Harbeck R. J., Teague J., Crossen G. R., Maul D. M., Childers P. L. Novel, rapid optical immunoassay technique for detection of group A streptococci from pharyngeal specimens: comparison with standard culture methods. J Clin Microbiol. 1993 Apr;31(4):839–844. doi: 10.1128/jcm.31.4.839-844.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Kellogg J. A. Suitability of throat culture procedures for detection of group A streptococci and as reference standards for evaluation of streptococcal antigen detection kits. J Clin Microbiol. 1990 Feb;28(2):165–169. doi: 10.1128/jcm.28.2.165-169.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Tolliver P. R., Roe M. H., Todd J. K. Detection of group A Streptococcus: comparison of solid and liquid culture media with and without selective antibiotics. Pediatr Infect Dis J. 1987 Jun;6(6):515–519. [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES