Comparison of BACTEC 9240 and BacT/Alert blood culture systems in an adult hospital.

J A Smith 1, E A Bryce 1, J H Ngui-Yen 1, F J Roberts 1
PMCID: PMC228295  PMID: 7665668

Abstract

In a study comparing the BACTEC 9240 (Becton Dickinson, Canada Inc., Mississauga, Ontario, Canada) and the BacT/Alert (Organon Teknika, Scarborough, Ontario, Canada) blood culture systems, 6,437 sets of four bottles of 10,412 cultures submitted were deemed acceptable for evaluation. There were 586 clinically significant isolates from 544 positive blood cultures. Of the 544 positive blood cultures, 329 were positive in both systems, 157 were positive in the BACTEC 9240 system alone, and 58 were positive in the BacT/Alert system alone (P < 0.001). These cultures represented 421 bacteremic episodes, of which 290 were detected by both systems, 84 were detected by the BACTEC 9240 system alone, and 47 were detected by the BacT/Alert system alone (P < 0.001). The difference between the two systems in terms of microbial recovery was attributable largely to differences in the ability to grow staphylococci. Of 82 monomicrobial isolates of Staphylococcus aureus, 46 were isolated by both systems, 30 were isolated by the BACTEC 9240 system alone, and 6 were isolated by the BacT/Alert system alone (P < 0.0001). A similar pattern was noted in the case of coagulase-negative staphylococci, of which 48 were isolated in both systems, 46 were isolated in the BACTEC 9240 system alone, and 5 were isolated in the BacT/Alert system alone (P < 0.0001). The false-positive rate in the BACTEC 9240 system was 0.5%, and that in the BacT/Alert system was 1.2%. Both systems provided satisfactory service mechanically, and in terms of computer software and costs, both systems were similar.(ABSTRACT TRUNCATED AT 250 WORDS)

Full Text

The Full Text of this article is available as a PDF (164.8 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Eng R. H., Bishburg E., Smith S. M., Scadutto P. Staphylococcus aureus bacteremia during therapy. J Infect Dis. 1987 Jun;155(6):1331–1335. doi: 10.1093/infdis/155.6.1331. [DOI] [PubMed] [Google Scholar]
  2. Hardy D. J., Hulbert B. B., Migneault P. C. Time to detection of positive BacT/Alert blood cultures and lack of need for routine subculture of 5- to 7-day negative cultures. J Clin Microbiol. 1992 Oct;30(10):2743–2745. doi: 10.1128/jcm.30.10.2743-2745.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Nolte F. S., Williams J. M., Jerris R. C., Morello J. A., Leitch C. D., Matushek S., Schwabe L. D., Dorigan F., Kocka F. E. Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240). J Clin Microbiol. 1993 Mar;31(3):552–557. doi: 10.1128/jcm.31.3.552-557.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Roberts F. J., Geere I. W., Coldman A. A three-year study of positive blood cultures, with emphasis on prognosis. Rev Infect Dis. 1991 Jan-Feb;13(1):34–46. doi: 10.1093/clinids/13.1.34. [DOI] [PubMed] [Google Scholar]
  5. Wilson M. L., Weinstein M. P., Reimer L. G., Mirrett S., Reller L. B. Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems. J Clin Microbiol. 1992 Feb;30(2):323–329. doi: 10.1128/jcm.30.2.323-329.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Zwadyk P., Jr, Pierson C. L., Young C. Comparison of Difco ESP and Organon Teknika BacT/Alert continuous-monitoring blood culture systems. J Clin Microbiol. 1994 May;32(5):1273–1279. doi: 10.1128/jcm.32.5.1273-1279.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES