Abstract
A lack of standardization of environmental monitoring techniques for Legionella spp. complicates the interpretation of results and comparisons of results from different institutions. A comparative assessment of techniques recommended by the Centers for Disease Control and Prevention, the Hygiene Institute (Graz, Austria), and our laboratory was performed. Variables investigated were sampling method (swabbing and collection of water samples [250 ml] before and after swabbing), method of concentration (none, filtration, and centrifugation), acid buffer treatment (no acid treatment, treatment for 3 min, and treatment for 15 min), and choice of medium (five formulations of buffered charcoal yeast extract agar with glycine, vancomycin, polymyxin B, anisomycin, or cycloheximide). Thirty-three sites in seven hospital buildings were studied. Recovery by swab correlated with recovery from water after swabbing (P < 0.05). However, the quantity of Legionella spp. recovered from swab specimens (mean, 3.0 x 10(4) CFU per swab) was greater than that recovered from water (mean, 4.7 x 10(3) CFU/250 ml). Filtration resulted in recovery rates (mean, 5.2 x 10(3) CFU/250 ml) higher than those by centrifugation (mean, 2.3 x 10(3) CFU/250 ml). Three minutes of acid buffer treatment to reduce overgrowth by commensal flora did not improve selectivity or sensitivity for Legionella spp. if glycine-containing selective media were used. Fifteen minutes of acid buffer treatment reduced recovery compared with that after a 3-min treatment. All glycine-containing media tested effectively inhibited background flora, but one selective medium containing dyes, glycine, vancomycin, and polymyxin B (DGVP) resulted in the greatest quantitative recovery of Legionella pneumophila.(ABSTRACT TRUNCATED AT 250 WORDS)
Full Text
The Full Text of this article is available as a PDF (253.7 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Best M., Yu V. L., Stout J., Goetz A., Muder R. R., Taylor F. Legionellaceae in the hospital water-supply. Epidemiological link with disease and evaluation of a method for control of nosocomial legionnaires' disease and Pittsburgh pneumonia. Lancet. 1983 Aug 6;2(8345):307–310. doi: 10.1016/s0140-6736(83)90290-8. [DOI] [PubMed] [Google Scholar]
- Brindle R. J., Stannett P. J., Cunliffe R. N. Legionella pneumophila: comparison of isolation from water specimens by centrifugation and filtration. Epidemiol Infect. 1987 Oct;99(2):241–247. doi: 10.1017/s0950268800067704. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Edelstein P. H. Comparative study of selective media for isolation of Legionella pneumophila from potable water. J Clin Microbiol. 1982 Oct;16(4):697–699. doi: 10.1128/jcm.16.4.697-699.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kusnetsov J. M., Jousimies-Somer H. R., Nevalainen A. I., Martikainen P. J. Isolation of Legionella from water samples using various culture methods. J Appl Bacteriol. 1994 Feb;76(2):155–162. doi: 10.1111/j.1365-2672.1994.tb01611.x. [DOI] [PubMed] [Google Scholar]
- Meigh R. E., Makin T., Scott M. H., Hart C. A. Legionella pneumophila serogroup 12 pneumonia in a renal transplant recipient: case report and environmental observations. J Hosp Infect. 1989 Apr;13(3):315–319. doi: 10.1016/0195-6701(89)90013-3. [DOI] [PubMed] [Google Scholar]
- Reinthaler F. F., Sattler J., Schaffler-Dullnig K., Weinmayr B., Marth E. Comparative study of procedures for isolation and cultivation of Legionella pneumophila from tap water in hospitals. J Clin Microbiol. 1993 May;31(5):1213–1216. doi: 10.1128/jcm.31.5.1213-1216.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stout J. E., Yu V. L., Muraca P., Joly J., Troup N., Tompkins L. S. Potable water as a cause of sporadic cases of community-acquired legionnaires' disease. N Engl J Med. 1992 Jan 16;326(3):151–155. doi: 10.1056/NEJM199201163260302. [DOI] [PubMed] [Google Scholar]
- Vickers R. M., Stout J. E., Yu V. L., Rihs J. D. Manual of culture methodology for Legionella. Semin Respir Infect. 1987 Dec;2(4):274–279. [PubMed] [Google Scholar]
- Wright J. B., Ruseska I., Athar M. A., Corbett S., Costerton J. W. Legionella pneumophila grows adherent to surfaces in vitro and in situ. Infect Control Hosp Epidemiol. 1989 Sep;10(9):408–415. doi: 10.1086/646062. [DOI] [PubMed] [Google Scholar]
- Yu V. L., Beam T. R., Jr, Lumish R. M., Vickers R. M., Fleming J., McDermott C., Romano J. Routine culturing for Legionella in the hospital environment may be a good idea: a three-hospital prospective study. Am J Med Sci. 1987 Aug;294(2):97–99. doi: 10.1097/00000441-198708000-00007. [DOI] [PubMed] [Google Scholar]