Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems.

F R Cockerill 3rd 1, C A Torgerson 1, G S Reed 1, E A Vetter 1, A L Weaver 1, J C Dale 1, G D Roberts 1, N K Henry 1, D M Ilstrup 1, J E Rosenblatt 1
PMCID: PMC228721  PMID: 8748264

Abstract

The ESP 80A aerobic blood culture of the ESP automated blood culture system (Difco Laboratories. Detroit, Mich.) was compared with two manual aerobic blood culture systems, the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek (Becton Dickinson, Cockeysville, Md.) systems, for the detection of bloodstream microorganisms from 5,845 blood samples for culture collected from adult patients with suspected septicemia. The bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated onto solid medium and this medium was incubated for 72 h. A total of 609 microorganisms were recovered from 546 blood cultures. There was no statistically significant difference in the total recovery of microorganisms for the ESP 80A system when compared with that for the Septi-Chek system (P = 0.083); however, the Isolator system recovered significantly more microorganisms overall than either the ESP 80A (P < 0.001) or the Septi-Chek (P < 0.001) system. When assessing individual probable pathogens, the Isolator system detected statistically significantly more Staphylococcus aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). Similarly, the Isolator system detected statistically significantly more bloodstream infections (septic episodes) caused by S. aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). In blood culture sets which produced growth of the same probable pathogens in the ESP 80A and the Isolator systems, there was no statistically significant difference in the median times to detection for all pathogens combined (P = 0.067). However, a similar comparison showed the Isolator and the ESP 80A systems to have statistically significantly shorter median detection times for all pathogens combined (P < 0.001) when they were independently compared with the Septi-Chek system. The ESP 80A system had 29 (0.5%) false-positive signals. The ESP system required less processing time than the Isolator system and eliminates the hands-on time for the detection of positive cultures required by the manual systems.

Full Text

The Full Text of this article is available as a PDF (192.8 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bates D. W., Goldman L., Lee T. H. Contaminant blood cultures and resource utilization. The true consequences of false-positive results. JAMA. 1991 Jan 16;265(3):365–369. [PubMed] [Google Scholar]
  2. Henry N. K., Grewell C. M., Van Grevenhof P. E., Ilstrup D. M., Washington J. A., 2nd Comparison of lysis-centrifugation with a biphasic blood culture medium for the recovery of aerobic and facultatively anaerobic bacteria. J Clin Microbiol. 1984 Sep;20(3):413–416. doi: 10.1128/jcm.20.3.413-416.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Kellogg J. A., Bankert D. A., Manzella J. P., Parsey K. S., Scott S. L., Cavanaugh S. H. Clinical comparison of isolator and thiol broth with ESP aerobic and anaerobic bottles for recovery of pathogens from blood. J Clin Microbiol. 1994 Sep;32(9):2050–2055. doi: 10.1128/jcm.32.9.2050-2055.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Kirkley B. A., Easley K. A., Basille B. A., Washington J. A. Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections. J Clin Microbiol. 1993 Aug;31(8):2114–2117. doi: 10.1128/jcm.31.8.2114-2117.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Kirkley B. A., Easley K. A., Washington J. A. Controlled clinical evaluation of Isolator and ESP aerobic blood culture systems for detection of bloodstream infections. J Clin Microbiol. 1994 Jun;32(6):1547–1549. doi: 10.1128/jcm.32.6.1547-1549.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Morello J. A., Leitch C., Nitz S., Dyke J. W., Andruszewski M., Maier G., Landau W., Beard M. A. Detection of bacteremia by Difco ESP blood culture system. J Clin Microbiol. 1994 Mar;32(3):811–818. doi: 10.1128/jcm.32.3.811-818.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES