Abstract
We evaluated the COBAS AMPLICOR (CA) PCR system (Roche Diagnostic Systems) designed for automated PCR amplification and detection of nucleic acids from infectious agents in clinical samples. The Roche AMPLICOR microwell plate (MWP) PCR was the reference method. CA amplifies target nucleic acid, captures the biotinylated amplification products by using magnetic particles coated with specific oligonucleotide probes, and detects the bound products colorimetrically. For Mycobacterium tuberculosis, the correlation of the results of CA tests with those of MWP tests was 100% with 230 samples, including 20 culture-positive samples. For hepatitis C virus, the correlation was 100% with 214 samples, including 60 positive samples. MultiPlex CA analysis of 199 cervical specimens for Chlamydia trachomatis, Neisseria gonorrhoeae, and the internal control gave 100% concordance. These samples included 19 C. trachomatis and 3 N. gonorrhoeae culture-positive samples. Overall, the agreement between PCR methods for all 842 comparisons was 100%. Compared with culture, the sensitivities of the assays for C. trachomatis and M tuberculosis were > or = 95%. After spiking alternating amplification tubes in the CA system with 10(14) copies of the Chlamydia amplicon per ml, we were unable to demonstrate any carryover cross-contamination of negative samples. Using the criteria of the College of American Pathologists workload recording method, we found that the total hands-on time to produce CA PCR results was 4.4, 7.9, and 3.3 min for M. tuberculosis, hepatis C virus, and the MultiPlexed assay for chlamydia plus gonorrhea and an internal control, respectively. The CA system brings true PCR automation to laboratories. In addition to the accuracy of automated results, the CA system provides labor savings, provides containment of the amplification and detection components of PCR, and supports both MultiPlex amplification and sequential algorithm (ReFlex) detection of analytes.
Full Text
The Full Text of this article is available as a PDF (333.5 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Aoki M., Katayama T., Yamagishi F., Yokota S., Kameda K., Saito H., Hara K., Ezaki T., Kawai T., Yotsumoto H. [Efficacy of PCR-microwell plate hybridization method (Amplicor Mycobacterium) for detection of M. tuberculosis, M. avium and/or M. intracellulare in clinical specimens]. Kekkaku. 1994 Oct;69(10):593–605. [PubMed] [Google Scholar]
- Bass C. A., Jungkind D. L., Silverman N. S., Bondi J. M. Clinical evaluation of a new polymerase chain reaction assay for detection of Chlamydia trachomatis in endocervical specimens. J Clin Microbiol. 1993 Oct;31(10):2648–2653. doi: 10.1128/jcm.31.10.2648-2653.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Beavis K. G., Lichty M. B., Jungkind D. L., Giger O. Evaluation of Amplicor PCR for direct detection of Mycobacterium tuberculosis from sputum specimens. J Clin Microbiol. 1995 Oct;33(10):2582–2586. doi: 10.1128/jcm.33.10.2582-2586.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Goto M., Okuzumi K., Sakai Y., Takewaki S., Tachikawa N., Iwamoto A., Kimura S., Shimada K. [Comparison of amplified Mycobacterium Tuberculosis Direct Test (MTD), Amplicor Mycobacteria kit (Amplicor) and PCR method for detection Mycobacterium tuberculosis in clinical specimens]. Kansenshogaku Zasshi. 1995 May;69(5):539–545. doi: 10.11150/kansenshogakuzasshi1970.69.539. [DOI] [PubMed] [Google Scholar]
- Haase A. M., Bagshaw S., George P. M. Improved detection of Chlamydia trachomatis in endocervical samples by using a new polymerase chain reaction assay. N Z Med J. 1995 Jul 28;108(1004):292–294. [PubMed] [Google Scholar]
- Hino K., Sainokami S., Shimoda K., Niwa H., Iino S. Clinical course of acute hepatitis C and changes in HCV markers. Dig Dis Sci. 1994 Jan;39(1):19–27. doi: 10.1007/BF02090055. [DOI] [PubMed] [Google Scholar]
- Krajden M. Molecular detection of hepatitis C virus: impact of detection methodology on clinical and laboratory correlations. Crit Rev Clin Lab Sci. 1995;32(1):41–66. doi: 10.3109/10408369509084681. [DOI] [PubMed] [Google Scholar]
- Liebling M. R., Arkfeld D. G., Michelini G. A., Nishio M. J., Eng B. J., Jin T., Louie J. S. Identification of Neisseria gonorrhoeae in synovial fluid using the polymerase chain reaction. Arthritis Rheum. 1994 May;37(5):702–709. doi: 10.1002/art.1780370514. [DOI] [PubMed] [Google Scholar]
- Mahony J. B., Luinstra K. E., Sellors J. W., Pickard L., Chong S., Jang D., Chernesky M. A. Role of confirmatory PCRs in determining performance of Chlamydia Amplicor PCR with endocervical specimens from women with a low prevalence of infection. J Clin Microbiol. 1994 Oct;32(10):2490–2493. doi: 10.1128/jcm.32.10.2490-2493.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mitrani-Rosenbaum S., Tsvieli R., Lavie O., Boldes R., Anteby E., Shimonovitch S., Lazarovitch T., Friedmann A. Simultaneous detection of three common sexually transmitted agents by polymerase chain reaction. Am J Obstet Gynecol. 1994 Sep;171(3):784–790. doi: 10.1016/0002-9378(94)90098-1. [DOI] [PubMed] [Google Scholar]
- Navas S., Carreño V. Semiquantification by Amplicor assay of hepatitis C virus genome during therapy. J Hepatol. 1995;22(1 Suppl):115–117. [PubMed] [Google Scholar]
- Nolte F. S., Thurmond C., Fried M. W. Preclinical evaluation of AMPLICOR hepatitis C virus test for detection of hepatitis C virus RNA. J Clin Microbiol. 1995 Jul;33(7):1775–1778. doi: 10.1128/jcm.33.7.1775-1778.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vuorinen P., Miettinen A., Vuento R., Hällström O. Direct detection of Mycobacterium tuberculosis complex in respiratory specimens by Gen-Probe Amplified Mycobacterium Tuberculosis Direct Test and Roche Amplicor Mycobacterium Tuberculosis Test. J Clin Microbiol. 1995 Jul;33(7):1856–1859. doi: 10.1128/jcm.33.7.1856-1859.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zeuzem S., Rüster B., Roth W. K. Clinical evaluation of a new polymerase chain reaction assay (Amplicor HCV) for detection of hepatitis C virus. Z Gastroenterol. 1994 Jun;32(6):342–347. [PubMed] [Google Scholar]
