Abstract
The photochemical inactivation of amplicons by isopsoralen (IP-10) has been suggested as a possible means to prevent PCR carryover contamination. To evaluate the technique, serial dilutions of amplicons (10(11) to 10(3)) from the Borrelia burgdorferi OSP A gene were amplified in the presence of 0, 25, 50, and 100 micrograms of IP-10 per ml for 45 cycles. The PCR products were exposed to UV light for 15 min to activate IP-10 and sterilize the amplicons. One microliter of each sterilized sample was reamplified for an additional 45 cycles. The PCR products were then resolved in an agarose gel, blotted onto a nylon membrane, and probed with an alkaline phosphatase-conjugated chemiluminescent probe. Although IP-10 at concentrations of 50 and 100 micrograms/ml effectively sterilized up to 10(11) amplicons, the compound was inhibitory to PCR. IP-10 at a concentration of 25 micrograms/ml had slight inhibitory effect on PCR and did not completely sterilized all of the amplicons. Therefore, in subsequent experiments AmpliWax was substituted for mineral oil, and PCR was performed on 10(9) to 10(3) amplicons as described above. Following the amplification, the PCR tubes were cooled to solidify the AmpliWax and inoculated with various concentrations of IP-10. With this technique, PCR products produced from as many as 10(9) target amplicons were effectively sterilized with 200 micrograms of IP-10 per ml. Similarly, the addition of IP-10 (50 micrograms/ml) before and after PCR was evaluated for the detection of B. burgdorferi in 62 ticks from a region of Southern Connecticut where the organism is highly endemic. PCR performed in the presence of 50 micrograms of IP-10 per ml detected B. burgdorferi-specific DNA in 17 of 62 ticks (27%) following gel electrophoresis and in 34 of 62 ticks (55%) following Southern blot hybridization of the PCR products. In contrast, post-PCR addition of IP-10 detected borrelia-specific DNA in 31 of 62 ticks (50%) following gel electrophoresis and in 46 of 62 ticks (64%) following Southern blot hybridization. We conclude that the replacement of mineral oil with AmpliWax can be useful in eliminating the inhibitory effects of IP-10 and other sterilizing agents for post-PCR sterilization of amplicons.
Full Text
The Full Text of this article is available as a PDF (298.6 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Aslanzadeh J. Application of hydroxylamine hydrochloride for post-PCR sterilization. Mol Cell Probes. 1993 Apr;7(2):145–150. doi: 10.1006/mcpr.1993.1020. [DOI] [PubMed] [Google Scholar]
- Carmody M. W., Vary C. P. Inhibition of DNA hybridization following partial dUTP substitution. Biotechniques. 1993 Oct;15(4):692–699. [PubMed] [Google Scholar]
- Cimino G. D., Metchette K. C., Tessman J. W., Hearst J. E., Isaacs S. T. Post-PCR sterilization: a method to control carryover contamination for the polymerase chain reaction. Nucleic Acids Res. 1991 Jan 11;19(1):99–107. doi: 10.1093/nar/19.1.99. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dwyer D. E., Saksena N. Failure of ultra-violet irradiation and autoclaving to eliminate PCR contamination. Mol Cell Probes. 1992 Feb;6(1):87–88. doi: 10.1016/0890-8508(92)90075-9. [DOI] [PubMed] [Google Scholar]
- Espy M. J., Smith T. F., Persing D. H. Dependence of polymerase chain reaction product inactivation protocols on amplicon length and sequence composition. J Clin Microbiol. 1993 Sep;31(9):2361–2365. doi: 10.1128/jcm.31.9.2361-2365.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fox J. C., Ait-Khaled M., Webster A., Emery V. C. Eliminating PCR contamination: is UV irradiation the answer? J Virol Methods. 1991 Aug;33(3):375–382. doi: 10.1016/0166-0934(91)90037-z. [DOI] [PubMed] [Google Scholar]
- Isaacs S. T., Tessman J. W., Metchette K. C., Hearst J. E., Cimino G. D. Post-PCR sterilization: development and application to an HIV-1 diagnostic assay. Nucleic Acids Res. 1991 Jan 11;19(1):109–116. doi: 10.1093/nar/19.1.109. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kox L. F., Rhienthong D., Miranda A. M., Udomsantisuk N., Ellis K., van Leeuwen J., van Heusden S., Kuijper S., Kolk A. H. A more reliable PCR for detection of Mycobacterium tuberculosis in clinical samples. J Clin Microbiol. 1994 Mar;32(3):672–678. doi: 10.1128/jcm.32.3.672-678.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kwok S., Higuchi R. Avoiding false positives with PCR. Nature. 1989 May 18;339(6221):237–238. doi: 10.1038/339237a0. [DOI] [PubMed] [Google Scholar]
- Longo M. C., Berninger M. S., Hartley J. L. Use of uracil DNA glycosylase to control carry-over contamination in polymerase chain reactions. Gene. 1990 Sep 1;93(1):125–128. doi: 10.1016/0378-1119(90)90145-h. [DOI] [PubMed] [Google Scholar]
- Persing D. H., Telford S. R., 3rd, Rys P. N., Dodge D. E., White T. J., Malawista S. E., Spielman A. Detection of Borrelia burgdorferi DNA in museum specimens of Ixodes dammini ticks. Science. 1990 Sep 21;249(4975):1420–1423. doi: 10.1126/science.2402635. [DOI] [PubMed] [Google Scholar]
- Prince A. M., Andrus L. PCR: how to kill unwanted DNA. Biotechniques. 1992 Mar;12(3):358–360. [PubMed] [Google Scholar]
- Rossen L., Nørskov P., Holmstrøm K., Rasmussen O. F. Inhibition of PCR by components of food samples, microbial diagnostic assays and DNA-extraction solutions. Int J Food Microbiol. 1992 Sep;17(1):37–45. doi: 10.1016/0168-1605(92)90017-w. [DOI] [PubMed] [Google Scholar]
- Rys P. N., Persing D. H. Preventing false positives: quantitative evaluation of three protocols for inactivation of polymerase chain reaction amplification products. J Clin Microbiol. 1993 Sep;31(9):2356–2360. doi: 10.1128/jcm.31.9.2356-2360.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Saksena N. K., Dwyer D., Barré-Sinoussi F. A "sentinel" technique for monitoring viral aerosol contamination. J Infect Dis. 1991 Nov;164(5):1021–1022. doi: 10.1093/infdis/164.5.1021. [DOI] [PubMed] [Google Scholar]
- Sarkar G., Sommer S. S. Shedding light on PCR contamination. Nature. 1990 Jan 4;343(6253):27–27. doi: 10.1038/343027a0. [DOI] [PubMed] [Google Scholar]
- Tompkins L. S. The use of molecular methods in infectious diseases. N Engl J Med. 1992 Oct 29;327(18):1290–1297. doi: 10.1056/NEJM199210293271808. [DOI] [PubMed] [Google Scholar]
- Victor T., Jordaan A., du Toit R., Van Helden P. D. Laboratory experience and guidelines for avoiding false positive polymerase chain reaction results. Eur J Clin Chem Clin Biochem. 1993 Aug;31(8):531–535. [PubMed] [Google Scholar]
- Wadowsky R. M., Laus S., Libert T., States S. J., Ehrlich G. D. Inhibition of PCR-based assay for Bordetella pertussis by using calcium alginate fiber and aluminum shaft components of a nasopharyngeal swab. J Clin Microbiol. 1994 Apr;32(4):1054–1057. doi: 10.1128/jcm.32.4.1054-1057.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Walder R. Y., Hayes J. R., Walder J. A. Use of PCR primers containing a 3'-terminal ribose residue to prevent cross-contamination of amplified sequences. Nucleic Acids Res. 1993 Sep 11;21(18):4339–4343. doi: 10.1093/nar/21.18.4339. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang J. T., Wang T. H., Sheu J. C., Lin S. M., Lin J. T., Chen D. S. Effects of anticoagulants and storage of blood samples on efficacy of the polymerase chain reaction assay for hepatitis C virus. J Clin Microbiol. 1992 Mar;30(3):750–753. doi: 10.1128/jcm.30.3.750-753.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yoshii T., Tamura K., Taniguchi T., Akiyama K., Ishiyama I. [Water-soluble eumelanin as a PCR-inhibitor and a simple method for its removal]. Nihon Hoigaku Zasshi. 1993 Aug;47(4):323–329. [PubMed] [Google Scholar]
- Zhen L., Swank R. T. A simple and high yield method for recovering DNA from agarose gels. Biotechniques. 1993 Jun;14(6):894–898. [PubMed] [Google Scholar]
- Zhu Y. S., Isaacs S. T., Cimino C. D., Hearst J. E. The use of exonuclease III for polymerase chain reaction sterilization. Nucleic Acids Res. 1991 May 11;19(9):2511–2511. doi: 10.1093/nar/19.9.2511. [DOI] [PMC free article] [PubMed] [Google Scholar]
- van den Brule A. J., Claas E. C., du Maine M., Melchers W. J., Helmerhorst T., Quint W. G., Lindeman J., Meijer C. J., Walboomers J. M. Use of anticontamination primers in the polymerase chain reaction for the detection of human papilloma virus genotypes in cervical scrapes and biopsies. J Med Virol. 1989 Sep;29(1):20–27. doi: 10.1002/jmv.1890290105. [DOI] [PubMed] [Google Scholar]
