Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1997 Jan;35(1):174–178. doi: 10.1128/jcm.35.1.174-178.1997

False-positive results in immunoglobulin M (IgM) toxoplasma antibody tests and importance of confirmatory testing: the Platelia Toxo IgM test.

O Liesenfeld 1, C Press 1, J G Montoya 1, R Gill 1, J L Isaac-Renton 1, K Hedman 1, J S Remington 1
PMCID: PMC229533  PMID: 8968902

Abstract

Although tests for detection of immunoglobulin M (IgM) toxoplasma antibodies have been reported to have a high degree of accuracy, it is well recognized by investigators in the United States and Europe that false-positive results may occur with many of these tests, at times to an alarming degree. Unfortunately, this information is not well documented in the literature. Studies on various toxoplasma IgM test kits are frequently flawed. The investigators often use reference tests which have not previously been carefully evaluated as well as sera that were not appropriate to answer the question of how often false-positive results might occur. We recently had the unique opportunity to evaluate the accuracy of the Platelia Toxo IgM test in 575 serum samples obtained during an outbreak of toxoplasmosis which occurred in 1995 in the Capital Regional District of British Columbia, Canada. When compared with results obtained in a reference IgM enzyme-linked immunosorbent assay (ELISA), the Platelia Toxo IgM test had a sensitivity of 99.4%, specificity of 49.2%, positive predictive value of 51.9%, negative predictive value of 99.3%, and an overall agreement of 67.0%. In an attempt to resolve discrepancies between these two tests, a serological profile (Sabin-Feldman dye test, IgA and IgE antibody tests, differential agglutination [AC/HS] test, and IgG avidity method) was performed. Of 153 serum samples that were positive in the Platelia Toxo IgM test and negative in the IgM ELISA, 71 (46.4%) were negative in the Sabin-Feldman dye test. Of the serum samples that were positive in the dye test, 77 (93.9%) had a serological profile most compatible with an infection acquired in the distant past. These results reveal high numbers of false-positive results in the Platelia Toxo IgM test and highlight the importance of appropriate evaluation of commercial tests that are currently being marked. Our results also emphasize the importance of confirmatory testing to determine whether the results of an IgM antibody test reflect the likelihood of a recently acquired infection.

Full Text

The Full Text of this article is available as a PDF (167.6 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Ashburn D., Evans R., Skinner L. J., Chatterton J. M., Joss A. W., Ho-Yen D. O. Comparison of relative uses of commercial assays for Toxoplasma gondii IgM antibodies. J Clin Pathol. 1992 Jun;45(6):483–486. doi: 10.1136/jcp.45.6.483. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Bobić B., Sibalić D., Djurković-Djaković O. High levels of IgM antibodies specific for Toxoplasma gondii in pregnancy 12 years after primary toxoplasma infection. Case report. Gynecol Obstet Invest. 1991;31(3):182–184. doi: 10.1159/000293151. [DOI] [PubMed] [Google Scholar]
  3. Candolfi E., Ramirez R., Hadju M. P., Shubert C., Remington J. S. The Vitek immunodiagnostic assay for detection of immunoglobulin M toxoplasma antibodies. Clin Diagn Lab Immunol. 1994 Jul;1(4):401–405. doi: 10.1128/cdli.1.4.401-405.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Crouch C. F. Enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence. J Clin Pathol. 1995 Jul;48(7):652–657. doi: 10.1136/jcp.48.7.652. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Dannemann B. R., Vaughan W. C., Thulliez P., Remington J. S. Differential agglutination test for diagnosis of recently acquired infection with Toxoplasma gondii. J Clin Microbiol. 1990 Sep;28(9):1928–1933. doi: 10.1128/jcm.28.9.1928-1933.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Del Bono V., Canessa A., Bruzzi P., Fiorelli M. A., Terragna A. Significance of specific immunoglobulin M in the chronological diagnosis of 38 cases of toxoplasmic lymphadenopathy. J Clin Microbiol. 1989 Sep;27(9):2133–2135. doi: 10.1128/jcm.27.9.2133-2135.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Gorgievski-Hrisoho M., Germann D., Matter L. Diagnostic implications of kinetics of immunoglobulin M and A antibody responses to Toxoplasma gondii. J Clin Microbiol. 1996 Jun;34(6):1506–1511. doi: 10.1128/jcm.34.6.1506-1511.1996. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Goullier-Fleuret A., Picot S. Etude multicentrique de l'enzymun-test Toxo-IgG et IgM. Ann Biol Clin (Paris) 1989;47(7):397–400. [PubMed] [Google Scholar]
  9. Hall A. V., Johnson J. D., Stevens P. J., Renton N. E., Holliman R. E. Measurement of Toxoplasma IgM by a microparticle capture enzyme immuno-assay. J Med Microbiol. 1993 Jan;38(1):34–37. doi: 10.1099/00222615-38-1-34. [DOI] [PubMed] [Google Scholar]
  10. Hedman K., Lappalainen M., Seppäiä I., Mäkelä O. Recent primary toxoplasma infection indicated by a low avidity of specific IgG. J Infect Dis. 1989 Apr;159(4):736–740. doi: 10.1093/infdis/159.4.736. [DOI] [PubMed] [Google Scholar]
  11. Herbrink P., van Loon A. M., Rotmans J. P., van Knapen F., van Dijk W. C. Interlaboratory evaluation of indirect enzyme-linked immunosorbent assay, antibody capture enzyme-linked immunosorbent assay, and immunoblotting for detection of immunoglobulin M antibodies to Toxoplasma gondii. J Clin Microbiol. 1987 Jan;25(1):100–105. doi: 10.1128/jcm.25.1.100-105.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Ilstrup D. M. Statistical methods in microbiology. Clin Microbiol Rev. 1990 Jul;3(3):219–226. doi: 10.1128/cmr.3.3.219. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Joynson D. H., Payne R. A., Balfour A. H., Prestage E. S., Fleck D. G., Chessum B. S. Five commercial enzyme linked immunosorbent assay kits for toxoplasma specific IgM antibody. J Clin Pathol. 1989 Jun;42(6):653–657. doi: 10.1136/jcp.42.6.653. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Lappalainen M., Koskela P., Koskiniemi M., Ammälä P., Hiilesmaa V., Teramo K., Raivio K. O., Remington J. S., Hedman K. Toxoplasmosis acquired during pregnancy: improved serodiagnosis based on avidity of IgG. J Infect Dis. 1993 Mar;167(3):691–697. doi: 10.1093/infdis/167.3.691. [DOI] [PubMed] [Google Scholar]
  15. Liesenfeld O., Press C., Flanders R., Ramirez R., Remington J. S. Study of Abbott Toxo IMx system for detection of immunoglobulin G and immunoglobulin M toxoplasma antibodies: value of confirmatory testing for diagnosis of acute toxoplasmosis. J Clin Microbiol. 1996 Oct;34(10):2526–2530. doi: 10.1128/jcm.34.10.2526-2530.1996. [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Luyasu V., Robert A. R., Schaefer L., Macioszek J. Multicenter evaluation of a new commercial assay for detection of immunoglobulin M antibodies to Toxoplasma gondii. Multicenter Study Group. Eur J Clin Microbiol Infect Dis. 1995 Sep;14(9):787–793. doi: 10.1007/BF01690994. [DOI] [PubMed] [Google Scholar]
  17. Montoya J. G., Remington J. S. Studies on the serodiagnosis of toxoplasmic lymphadenitis. Clin Infect Dis. 1995 Apr;20(4):781–789. doi: 10.1093/clinids/20.4.781. [DOI] [PubMed] [Google Scholar]
  18. Naot Y., Remington J. S. An enzyme-linked immunosorbent assay for detection of IgM antibodies to Toxoplasma gondii: use for diagnosis of acute acquired toxoplasmosis. J Infect Dis. 1980 Nov;142(5):757–766. doi: 10.1093/infdis/142.5.757. [DOI] [PubMed] [Google Scholar]
  19. Pelloux H., Ciapa P., Goullier-Fleuret A., Ambroise-Thomas P. Evaluation du système Vidas pour le diagnostic sérologique de la toxoplasmose. Ann Biol Clin (Paris) 1993;51(10-11):875–878. [PubMed] [Google Scholar]
  20. Petithory J. C., Reiter-Owona I., Berthelot F., Milgram M., De Loye J., Petersen E. Performance of European laboratories testing serum samples for Toxoplasma gondii. Eur J Clin Microbiol Infect Dis. 1996 Jan;15(1):45–49. doi: 10.1007/BF01586184. [DOI] [PubMed] [Google Scholar]
  21. Rotmans J., Duchenne W., Linschooten C., In't Veld N., Polderman A. Comparative study of three immunoassays for detection of immunoglobulin M antibodies against Toxoplasma gondii. Eur J Clin Microbiol Infect Dis. 1988 Aug;7(4):535–538. doi: 10.1007/BF01962609. [DOI] [PubMed] [Google Scholar]
  22. Sabin A. B., Feldman H. A. Dyes as Microchemical Indicators of a New Immunity Phenomenon Affecting a Protozoon Parasite (Toxoplasma). Science. 1948 Dec 10;108(2815):660–663. doi: 10.1126/science.108.2815.660. [DOI] [PubMed] [Google Scholar]
  23. Safford J. W., Abbott G. G., Craine M. C., MacDonald R. G. Automated microparticle enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii. J Clin Pathol. 1991 Mar;44(3):238–242. doi: 10.1136/jcp.44.3.238. [DOI] [PMC free article] [PubMed] [Google Scholar]
  24. Schaefer L. E., Dyke J. W., Meglio F. D., Murray P. R., Crafts W., Niles A. C. Evaluation of microparticle enzyme immunoassays for immunoglobulins G and M to rubella virus and Toxoplasma gondii on the Abbott IMx automated analyzer. J Clin Microbiol. 1989 Nov;27(11):2410–2413. doi: 10.1128/jcm.27.11.2410-2413.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Stepick-Biek P., Thulliez P., Araujo F. G., Remington J. S. IgA antibodies for diagnosis of acute congenital and acquired toxoplasmosis. J Infect Dis. 1990 Jul;162(1):270–273. doi: 10.1093/infdis/162.1.270. [DOI] [PubMed] [Google Scholar]
  26. Van Enk R. A., James K. K., Thompson K. D. Evaluation of three commercial enzyme immunoassays for toxoplasma and cytomegalovirus antibodies. Am J Clin Pathol. 1991 Mar;95(3):428–434. doi: 10.1093/ajcp/95.3.428. [DOI] [PubMed] [Google Scholar]
  27. Verhofstede C., Van Renterghem L., Plum J. Comparison of six commercial enzyme linked immunosorbent assays for detecting IgM antibodies against Toxoplasma gondii. J Clin Pathol. 1989 Dec;42(12):1285–1290. doi: 10.1136/jcp.42.12.1285. [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Wong S. Y., Hajdu M. P., Ramirez R., Thulliez P., McLeod R., Remington J. S. Role of specific immunoglobulin E in diagnosis of acute toxoplasma infection and toxoplasmosis. J Clin Microbiol. 1993 Nov;31(11):2952–2959. doi: 10.1128/jcm.31.11.2952-2959.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
  29. Wong S. Y., Remington J. S. Toxoplasmosis in pregnancy. Clin Infect Dis. 1994 Jun;18(6):853–862. doi: 10.1093/clinids/18.6.853. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES