A solid-phase erythrocyte adherence assay has been developed for the serological detection of reagin antibodies in syphilis. Capture-S (Immucor, Inc., Norcross, Ga.) is a nontreponemal, qualitative screening test for the detection of immunoglobulin G (IgG) and IgM antilipid antibodies in serum or plasma samples from blood donors. The Capture-S assay utilizes a modified Venereal Disease Research Laboratory antigen bound to microtitration wells and anti-IgG- plus anti-IgM-coated indicator erythrocytes as the detection system. The Capture-S assay was evaluated at six separate sites on 10,942 specimens. For patient samples of clinically diagnosed syphilis categories (n = 366), the Capture-S assay yielded a sensitivity of 80.7% versus 80.3% for the rapid plasma reagin (RPR) card test (Becton Dickinson Microbiology Systems, Cockeysville, Md.). In comparative experiments on patient and donor samples (n = 10,222), the Capture-S assay demonstrated a sensitivity of 94% compared to 91.2% for the RPR card test. The Capture-S and RPR card tests produced essentially equivalent specificities of 99.2% and 99.3%, respectively, for this sample population. For five test sites, the Capture-S and RPR card test demonstrated a 98.3% agreement (10,085 of 10,264) of test results. These evaluations indicate that the Capture-S compares favorably to the RPR card test in assay sensitivity and specificity, with the added benefits of ease of use, accommodation of high-volume testing, and potential for automation.
Full Text
The Full Text of this article is available as a PDF (187.6 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- COOMBS R. R., MARKS J., BEDFORD D. Specific mixed agglutination: mixed erythrocyte-platelet anti-globulin reaction for the detection of platelet antibodies. Br J Haematol. 1956 Jan;2(1):84–94. doi: 10.1111/j.1365-2141.1956.tb06689.x. [DOI] [PubMed] [Google Scholar]
- Cannefax G. R., Norins L. C., Gillespie E. J. Immunology of syphilis. Annu Rev Med. 1967;18:471–482. doi: 10.1146/annurev.me.18.020167.002351. [DOI] [PubMed] [Google Scholar]
- HOGMAN C. The principle of mixed agglutination applied to tissue culture systems; a method for study of cell-bound blood-group antigens. Vox Sang. 1959 Feb;4(1):12–20. doi: 10.1111/j.1423-0410.1959.tb04307.x. [DOI] [PubMed] [Google Scholar]
- Larsen S. A., Hambie E. A., Pettit D. E., Perryman M. W., Kraus S. J. Specificity, sensitivity, and reproducibility among the fluorescent treponemal antibody-absorption test, the microhemagglutination assay for Treponema pallidum antibodies, and the hemagglutination treponemal test for syphilis. J Clin Microbiol. 1981 Oct;14(4):441–445. doi: 10.1128/jcm.14.4.441-445.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nayar R., Campos J. M. Evaluation of the DCL Syphilis-G enzyme immunoassay test kit for the serologic diagnosis of syphilis. Am J Clin Pathol. 1993 Mar;99(3):282–285. doi: 10.1093/ajcp/99.3.282. [DOI] [PubMed] [Google Scholar]
- Pedersen N. S., Orum O., Mouritsen S. Enzyme-linked immunosorbent assay for detection of antibodies to the venereal disease research laboratory (VDRL) antigen in syphilis. J Clin Microbiol. 1987 Sep;25(9):1711–1716. doi: 10.1128/jcm.25.9.1711-1716.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Peter C. R., Thompson M. A., Wilson D. L. False-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests. J Clin Microbiol. 1979 Mar;9(3):369–372. doi: 10.1128/jcm.9.3.369-372.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pettit D. E., Larsen S. A., Harbec P. S., Feeley J. C., Parham C. E., Cruce D. D., Hambie E. A., Perryman M. W. Toluidine red unheated serum test, a nontreponemal test for syphilis. J Clin Microbiol. 1983 Nov;18(5):1141–1145. doi: 10.1128/jcm.18.5.1141-1145.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Plapp F. V., Sinor L. T., Rachel J. M., Beck M. L., Coenen W. M., Bayer W. L. A solid phase antibody screen. Am J Clin Pathol. 1984 Dec;82(6):719–721. doi: 10.1093/ajcp/82.6.719. [DOI] [PubMed] [Google Scholar]
- Pope V., Hunter E. F., Feeley J. C. Evaluation of the microenzyme-linked immunosorbent assay with Treponema pallidum antigen. J Clin Microbiol. 1982 Apr;15(4):630–634. doi: 10.1128/jcm.15.4.630-634.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sinor L. T. Advances in solid-phase red cell adherence methods and transfusion serology. Transfus Med Rev. 1992 Jan;6(1):26–31. doi: 10.1016/s0887-7963(92)70153-9. [DOI] [PubMed] [Google Scholar]
- Stevens R. W., Schmitt M. E. Evaluation of an enzyme-linked immunosorbent assay for treponemal antibody. J Clin Microbiol. 1985 Mar;21(3):399–402. doi: 10.1128/jcm.21.3.399-402.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stone D. L., Eatz R. A., Rolib S. D., Farlow S. J., Hudson G. S., Sinor L. T. Red cell antibody identification by solid phase red cell adherence utilizing dried RBC monolayers. Immunohematology. 1990;6(1):12–17. [PubMed] [Google Scholar]
- White T. J., Fuller S. A. Visuwell Reagin, a non-treponemal enzyme-linked immunosorbent assay for the serodiagnosis of syphilis. J Clin Microbiol. 1989 Oct;27(10):2300–2304. doi: 10.1128/jcm.27.10.2300-2304.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Young H., Moyes A., McMillan A., Robertson D. H. Screening for treponemal infection by a new enzyme immunoassay. Genitourin Med. 1989 Apr;65(2):72–78. doi: 10.1136/sti.65.2.72. [DOI] [PMC free article] [PubMed] [Google Scholar]