Abstract
In a recent clinical trial, 248 triple-lumen catheters were removed from patients in an intensive care unit, and their tip and subcutaneous segments were cultured by both the sonication and roll plate methods; for 191 of these catheters, flush cultures of all three catheter lumens were also performed. Previously published quantitative endpoints were used to define significant catheter colonization. By using a composite index as a definition of colonization (any of the seven types of cultures meeting quantitative criteria), sonication of the subcutaneous segment was the most sensitive at detecting colonization (58%), followed by sonication of the catheter tip (53%). Sonication of both the subcutaneous and tip segments was 20% more sensitive than sonication of an adjacent catheter segment by the roll plate method (P < 0.05). The greater sensitivity of the sonication method could be attributed to its greater ability than the roll plate method to detect catheter lumen colonization (82 versus 57%, respectively; P = 0.01). A greater number of positive catheter segment cultures were found for colonized catheters from patients with associated bacteremia than for colonized catheters from patients without bacteremia (57 versus 37%; P = 0.004), making any culture method more likely to identify them. For catheters with significant colonization of only one site, the localization was as follows: 36.7% subcutaneous segment, 36.7% catheter lumen, and 26.6% tip segment. These findings suggest that the current practice of culturing a single segment of a central vascular catheter is inadequate and needs to be reexamined. They further suggest that initial colonization of the catheter lumen and tip segments may be more important than previously thought and may require a change in thinking of strategies designed to prevent catheter infection.
Full Text
The Full Text of this article is available as a PDF (91.9 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Andremont A., Paulet R., Nitenberg G., Hill C. Value of semiquantitative cultures of blood drawn through catheter hubs for estimating the risk of catheter tip colonization in cancer patients. J Clin Microbiol. 1988 Nov;26(11):2297–2299. doi: 10.1128/jcm.26.11.2297-2299.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Benezra D., Kiehn T. E., Gold J. W., Brown A. E., Turnbull A. D., Armstrong D. Prospective study of infections in indwelling central venous catheters using quantitative blood cultures. Am J Med. 1988 Oct;85(4):495–498. doi: 10.1016/s0002-9343(88)80084-6. [DOI] [PubMed] [Google Scholar]
- Bjornson H. S., Colley R., Bower R. H., Duty V. P., Schwartz-Fulton J. T., Fischer J. E. Association between microorganism growth at the catheter insertion site and colonization of the catheter in patients receiving total parenteral nutrition. Surgery. 1982 Oct;92(4):720–727. [PubMed] [Google Scholar]
- Brun-Buisson C., Abrouk F., Legrand P., Huet Y., Larabi S., Rapin M. Diagnosis of central venous catheter-related sepsis. Critical level of quantitative tip cultures. Arch Intern Med. 1987 May;147(5):873–877. [PubMed] [Google Scholar]
- Capdevila J. A., Planes A. M., Palomar M., Gasser I., Almirante B., Pahissa A., Crespo E., Martínez-Vázquez J. M. Value of differential quantitative blood cultures in the diagnosis of catheter-related sepsis. Eur J Clin Microbiol Infect Dis. 1992 May;11(5):403–407. doi: 10.1007/BF01961854. [DOI] [PubMed] [Google Scholar]
- Cercenado E., Ena J., Rodríguez-Créixems M., Romero I., Bouza E. A conservative procedure for the diagnosis of catheter-related infections. Arch Intern Med. 1990 Jul;150(7):1417–1420. [PubMed] [Google Scholar]
- Cheesbrough J. S., Finch R. G., Burden R. P. A prospective study of the mechanisms of infection associated with hemodialysis catheters. J Infect Dis. 1986 Oct;154(4):579–589. doi: 10.1093/infdis/154.4.579. [DOI] [PubMed] [Google Scholar]
- Cleri D. J., Corrado M. L., Seligman S. J. Quantitative culture of intravenous catheters and other intravascular inserts. J Infect Dis. 1980 Jun;141(6):781–786. doi: 10.1093/infdis/141.6.781. [DOI] [PubMed] [Google Scholar]
- Collignon P. J., Soni N., Pearson I. Y., Woods W. P., Munro R., Sorrell T. C. Is semiquantitative culture of central vein catheter tips useful in the diagnosis of catheter-associated bacteremia? J Clin Microbiol. 1986 Oct;24(4):532–535. doi: 10.1128/jcm.24.4.532-535.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Collignon P., Chan R., Munro R. Rapid diagnosis of intravascular catheter-related sepsis. Arch Intern Med. 1987 Sep;147(9):1609–1612. [PubMed] [Google Scholar]
- Cooper G. L., Hopkins C. C. Rapid diagnosis of intravascular catheter-associated infection by direct Gram staining of catheter segments. N Engl J Med. 1985 May 2;312(18):1142–1147. doi: 10.1056/NEJM198505023121802. [DOI] [PubMed] [Google Scholar]
- Coutlée F., Lemieux C., Paradis J. F. Value of direct catheter staining in the diagnosis of intravascular-catheter-related infection. J Clin Microbiol. 1988 Jun;26(6):1088–1090. doi: 10.1128/jcm.26.6.1088-1090.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Douard M. C., Clementi E., Arlet G., Marie O., Jacob L., Schremmer B., Rouveau M., Garrouste M. T., Eurin B. Negative catheter-tip culture and diagnosis of catheter-related bacteremia. Nutrition. 1994 Sep-Oct;10(5):397–404. [PubMed] [Google Scholar]
- Fan S. T., Teoh-Chan C. H., Lau K. F. Evaluation of central venous catheter sepsis by differential quantitative blood culture. Eur J Clin Microbiol Infect Dis. 1989 Feb;8(2):142–144. doi: 10.1007/BF01963898. [DOI] [PubMed] [Google Scholar]
- Flowers R. H., 3rd, Schwenzer K. J., Kopel R. F., Fisch M. J., Tucker S. I., Farr B. M. Efficacy of an attachable subcutaneous cuff for the prevention of intravascular catheter-related infection. A randomized, controlled trial. JAMA. 1989 Feb 10;261(6):878–883. [PubMed] [Google Scholar]
- Flynn P. M., Shenep J. L., Barrett F. F. Differential quantitation with a commercial blood culture tube for diagnosis of catheter-related infection. J Clin Microbiol. 1988 May;26(5):1045–1046. doi: 10.1128/jcm.26.5.1045-1046.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Flynn P. M., Shenep J. L., Stokes D. C., Barrett F. F. In situ management of confirmed central venous catheter-related bacteremia. Pediatr Infect Dis J. 1987 Aug;6(8):729–734. doi: 10.1097/00006454-198708000-00007. [DOI] [PubMed] [Google Scholar]
- Gutiérrez J., Leon C., Matamoros R., Nogales C., Martín E. Catheter-related bacteremia and fungemia. Reliability of two methods for catheter culture. Diagn Microbiol Infect Dis. 1992 Sep-Oct;15(7):575–578. doi: 10.1016/0732-8893(90)90033-r. [DOI] [PubMed] [Google Scholar]
- Heard S. O., Davis R. F., Sherertz R. J., Mikhail M. S., Gallagher R. C., Layon A. J., Gallagher T. J. Influence of sterile protective sleeves on the sterility of pulmonary artery catheters. Crit Care Med. 1987 May;15(5):499–502. doi: 10.1097/00003246-198705000-00009. [DOI] [PubMed] [Google Scholar]
- Kristinsson K. G., Burnett I. A., Spencer R. C. Evaluation of three methods for culturing long intravascular catheters. J Hosp Infect. 1989 Oct;14(3):183–191. doi: 10.1016/0195-6701(89)90034-0. [DOI] [PubMed] [Google Scholar]
- Liñares J., Sitges-Serra A., Garau J., Pérez J. L., Martín R. Pathogenesis of catheter sepsis: a prospective study with quantitative and semiquantitative cultures of catheter hub and segments. J Clin Microbiol. 1985 Mar;21(3):357–360. doi: 10.1128/jcm.21.3.357-360.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Maki D. G., Cobb L., Garman J. K., Shapiro J. M., Ringer M., Helgerson R. B. An attachable silver-impregnated cuff for prevention of infection with central venous catheters: a prospective randomized multicenter trial. Am J Med. 1988 Sep;85(3):307–314. doi: 10.1016/0002-9343(88)90579-7. [DOI] [PubMed] [Google Scholar]
- Maki D. G., Weise C. E., Sarafin H. W. A semiquantitative culture method for identifying intravenous-catheter-related infection. N Engl J Med. 1977 Jun 9;296(23):1305–1309. doi: 10.1056/NEJM197706092962301. [DOI] [PubMed] [Google Scholar]
- McGeer A., Righter J. Improving our ability to diagnose infections associated with central venous catheters: value of Gram's staining and culture of entry site swabs. CMAJ. 1987 Dec 1;137(11):1009-15, 1021. [PMC free article] [PubMed] [Google Scholar]
- Mermel L. A., McCormick R. D., Springman S. R., Maki D. G. The pathogenesis and epidemiology of catheter-related infection with pulmonary artery Swan-Ganz catheters: a prospective study utilizing molecular subtyping. Am J Med. 1991 Sep 16;91(3B):197S–205S. doi: 10.1016/0002-9343(91)90369-9. [DOI] [PubMed] [Google Scholar]
- Moonens F., el Alami S., Van Gossum A., Struelens M. J., Serruys E. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis. J Clin Microbiol. 1994 Jun;32(6):1578–1579. doi: 10.1128/jcm.32.6.1578-1579.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mosca R., Curtas S., Forbes B., Meguid M. M. The benefits of Isolator cultures in the management of suspected catheter sepsis. Surgery. 1987 Oct;102(4):718–723. [PubMed] [Google Scholar]
- Moyer M. A., Edwards L. D., Farley L. Comparative culture methods on 101 intravenous catheters. Routine, semiquantitative, and blood cultures. Arch Intern Med. 1983 Jan;143(1):66–69. [PubMed] [Google Scholar]
- Pinilla J. C., Ross D. F., Martin T., Crump H. Study of the incidence of intravascular catheter infection and associated septicemia in critically ill patients. Crit Care Med. 1983 Jan;11(1):21–25. doi: 10.1097/00003246-198301000-00007. [DOI] [PubMed] [Google Scholar]
- Raad I. I., Sabbagh M. F., Rand K. H., Sherertz R. J. Quantitative tip culture methods and the diagnosis of central venous catheter-related infections. Diagn Microbiol Infect Dis. 1992 Jan;15(1):13–20. doi: 10.1016/0732-8893(92)90052-u. [DOI] [PubMed] [Google Scholar]
- Raad I., Costerton W., Sabharwal U., Sacilowski M., Anaissie E., Bodey G. P. Ultrastructural analysis of indwelling vascular catheters: a quantitative relationship between luminal colonization and duration of placement. J Infect Dis. 1993 Aug;168(2):400–407. doi: 10.1093/infdis/168.2.400. [DOI] [PubMed] [Google Scholar]
- Raucher H. S., Hyatt A. C., Barzilai A., Harris M. B., Weiner M. A., LeLeiko N. S., Hodes D. S. Quantitative blood cultures in the evaluation of septicemia in children with Broviac catheters. J Pediatr. 1984 Jan;104(1):29–33. doi: 10.1016/s0022-3476(84)80584-3. [DOI] [PubMed] [Google Scholar]
- Rello J., Coll P., Prats G. Laboratory diagnosis of catheter-related bacteremia. Scand J Infect Dis. 1991;23(5):583–588. doi: 10.3109/00365549109105182. [DOI] [PubMed] [Google Scholar]
- Rello J., Gatell J. M., Almirall J., Campistol J. M., Gonzalez J., Puig de la Bellacasa J. Evaluation of culture techniques for identification of catheter-related infection in hemodialysis patients. Eur J Clin Microbiol Infect Dis. 1989 Jul;8(7):620–622. doi: 10.1007/BF01968140. [DOI] [PubMed] [Google Scholar]
- Rushforth J. A., Hoy C. M., Kite P., Puntis J. W. Rapid diagnosis of central venous catheter sepsis. Lancet. 1993 Aug 14;342(8868):402–403. doi: 10.1016/0140-6736(93)92815-b. [DOI] [PubMed] [Google Scholar]
- Sherertz R. J., Falk R. J., Huffman K. A., Thomann C. A., Mattern W. D. Infections associated with subclavian Uldall catheters. Arch Intern Med. 1983 Jan;143(1):52–56. [PubMed] [Google Scholar]
- Sherertz R. J., Heard S. O., Raad I. I., Gentry L., Bowton D., Scuderi P., Hu J., Carruth W., Satishchandra B., Pepe J. Gamma radiation-sterilized, triple-lumen catheters coated with a low concentration of chlorhexidine were not efficacious at preventing catheter infections in intensive care unit patients. Antimicrob Agents Chemother. 1996 Sep;40(9):1995–1997. doi: 10.1128/aac.40.9.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sherertz R. J., Raad I. I., Belani A., Koo L. C., Rand K. H., Pickett D. L., Straub S. A., Fauerbach L. L. Three-year experience with sonicated vascular catheter cultures in a clinical microbiology laboratory. J Clin Microbiol. 1990 Jan;28(1):76–82. doi: 10.1128/jcm.28.1.76-82.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sitges-Serra A., Liñares J. Limitations of semiquantitative method for catheter culture. J Clin Microbiol. 1988 May;26(5):1074–1076. doi: 10.1128/jcm.26.5.1074-1076.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Snydman D. R., Gorbea H. F., Pober B. R., Majka J. A., Murray S. A., Perry L. K. Predictive value of surveillance skin cultures in total-parenteral-nutrition-related infection. Lancet. 1982 Dec 18;2(8312):1385–1388. doi: 10.1016/s0140-6736(82)91281-8. [DOI] [PubMed] [Google Scholar]
- Weightman N. C., Speller D. C. Pour plate blood cultures to detect bacteraemias related to indwelling central venous catheters. J Hosp Infect. 1986 Sep;8(2):203–204. doi: 10.1016/0195-6701(86)90048-4. [DOI] [PubMed] [Google Scholar]
- Widmer A. F., Nettleman M., Flint K., Wenzel R. P. The clinical impact of culturing central venous catheters. A prospective study. Arch Intern Med. 1992 Jun;152(6):1299–1302. [PubMed] [Google Scholar]
- Wing E. J., Norden C. W., Shadduck R. K., Winkelstein A. Use of quantitative bacteriologic techniques to diagnose catheter-related sepsis. Arch Intern Med. 1979 Apr;139(4):482–483. [PubMed] [Google Scholar]
- Zufferey J., Rime B., Francioli P., Bille J. Simple method for rapid diagnosis of catheter-associated infection by direct acridine orange staining of catheter tips. J Clin Microbiol. 1988 Feb;26(2):175–177. doi: 10.1128/jcm.26.2.175-177.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]