Skip to main content
. Author manuscript; available in PMC: 2008 May 13.
Published in final edited form as: Neuroscience. 2006 Jul 28;142(1):203–221. doi: 10.1016/j.neuroscience.2006.05.068

Table 1.

Parameters of sGLFP in standard horizontal slices (HS) and in slices of the IGL maintained in normal ACSF

sGLFP parameter Mean ± SD Min Max
Amplitude HS [mV] 0.292 ± 0.216 0.028 1.669
Amplitude IGL [mV] 0.244 ± 0.190 0.033 1.325
Rise time HS [ms] 86.62 ± 46.44 10 446
Rise time IGL [ms] 92.43 ± 47.98 8.2 367
Decay time HS [ms] 280.05 ± 145.37 16.9 510
Decay time IGL [ms] 239.79 ± 122.68 13.5 401
Area HS [mV ms]a 56.12 ± 47.02 5 330
Area IGL [mV ms]a 40.33 ± 36.55 5 265
HalfWidth HS [ms] 139.67 ± 82.34 13.3 666
HalfWidth IGL [ms] 130.03 ± 70.07 20 535
a

Number of sGLFPs in HS was NHS = 14,933 (33 recording sites), in IGL it was NIGL = 5468 (nine recording sites): in all pairs means were significantly different (P < 0.05).