Abstract
Methods for detecting total coliform bacteria in drinking water were compared using 1,483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a 10-tube fermentation tube (FT) technique, and the presence-absence (P-A) test. Each technique was evaluated using a 100-ml drinking water sample. Of the 1,483 samples tested, 336 (23%) contained coliforms as indicated by either one, two, or all three techniques. The FT detected 82%, the P-A detected 88%, and the MF detected 64% of these positives. All techniques simultaneously detected 55% of the positives. Evaluation of the confirmation efficiency of the P-A technique showed 94% of the presumptive positives confirming as coliforms. Thirteen different species of coliforms were identified from the 37 tests in which the P-A was positive but the MF and FT were negative. The P-A test was simple to inoculate and interpret and was considerably more sensitive than the MF and slightly more sensitive than the FT in detecting coliforms in this type of drinking water supply.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bissonnette G. K., Jezeski J. J., McFeters G. A., Stuart D. G. Evaluation of recovery methods to detect coliforms in water. Appl Environ Microbiol. 1977 Mar;33(3):590–595. doi: 10.1128/aem.33.3.590-595.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- CHAMBERS C. W. Relationship of coliform bacteria to gas production in media containing lactose. Public Health Rep. 1950 May 12;65(19):619–627. [PMC free article] [PubMed] [Google Scholar]
- Clark J. A. A presence-absence (P-A) test providing sensitive and inexpensive detection of coliforms, fecal coliforms, and fecal streptococci in municipal drinking water supplies. Can J Microbiol. 1968 Jan;14(1):13–18. doi: 10.1139/m68-003. [DOI] [PubMed] [Google Scholar]
- Clark J. A. The detection of various bacteria indicative of water pollution by a presence-absence (P-A) procedure. Can J Microbiol. 1969 Jul;15(7):771–780. doi: 10.1139/m69-135. [DOI] [PubMed] [Google Scholar]
- Clark J. A., Vlassoff L. T. Relationships among pollution indicator bacteria isolated from raw water and distribution systems by the presence-absence (P-A) test. Health Lab Sci. 1973 Jul;10(3):163–172. [PubMed] [Google Scholar]
- Evans T. M., LeChevallier M. W., Waarvick C. E., Seidler R. J. Coliform species recovered from untreated surface water and drinking water by the membrane filter, standard, and modified most-probable-number techniques. Appl Environ Microbiol. 1981 Mar;41(3):657–663. doi: 10.1128/aem.41.3.657-663.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Evans T. M., Seidler R. J., LeChevallier M. W. Impact of verification media and resuscitation on accuracy of the membrane filter total coliform enumeration technique. Appl Environ Microbiol. 1981 May;41(5):1144–1151. doi: 10.1128/aem.41.5.1144-1151.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Evans T. M., Waarvick C. E., Seidler R. J., LeChevallier M. W. Failure of the most-probable-number technique to detect coliforms in drinking water and raw water supplies. Appl Environ Microbiol. 1981 Jan;41(1):130–138. doi: 10.1128/aem.41.1.130-138.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- LeChevallier M. W., Cameron S. C., McFeters G. A. New medium for improved recovery of coliform bacteria from drinking water. Appl Environ Microbiol. 1983 Feb;45(2):484–492. doi: 10.1128/aem.45.2.484-492.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McFeters G. A., Cameron S. C., LeChevallier M. W. Influence of diluents, media, and membrane filters on detection fo injured waterborne coliform bacteria. Appl Environ Microbiol. 1982 Jan;43(1):97–103. doi: 10.1128/aem.43.1.97-103.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McFeters G. A., Stuart D. G. Survival of coliform bacteria in natural waters: field and laboratory studies with membrane-filter chambers. Appl Microbiol. 1972 Nov;24(5):805–811. doi: 10.1128/am.24.5.805-811.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Meadows P. S., Anderson J. G., Patel K., Mullins B. W. Variability in gas production by Escherichia coli in enrichment media and its relationship to pH. Appl Environ Microbiol. 1980 Aug;40(2):309–312. doi: 10.1128/aem.40.2.309-312.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Morgan G. B., Gubbins P., Morgan V. A critical appraisal of the membrane filter technic. Health Lab Sci. 1965 Oct;2(4):227–237. [PubMed] [Google Scholar]
- SHIPE E. L., Jr, CAMERON G. M. A comparison of the membrane filter with the most probable number method for coliform determinations from several waters. Appl Microbiol. 1954 Mar;2(2):85–88. doi: 10.1128/am.2.2.85-88.1954. [DOI] [PMC free article] [PubMed] [Google Scholar]