Abstract
The efficiency of virus recovery from water was investigated by using a method which enabled the concentration of a mixture of four enteroviruses with determination of their individual recovery efficiencies. The four viruses used (poliovirus 1, coxsackievirus A9, coxsackievirus B1, and echovirus 7) represented each of the four major subgroups of enteroviruses. This method, which was based on selective antibody neutralization, was used to investigate the effects of input water quality on enterovirus concentration by Balston filters (grade C; Balston, Inc., Lexington, Mass.) and organic flocculation. With tap water, the average recovery efficiency of the four viruses was 97%. Concentration from natural waters, including samples from two lakes (Lake Kinneret and the Hula Nature Reserve) and the Mediterranean Sea, resulted in similarly high average recovery efficiencies. Echovirus 7 was recovered with a slightly lower average efficiency from these types of water than were the other viruses. In comparison with other types of water, virus concentration from Jerusalem wastewater generally had a slightly lower efficiency of recovery, ranging from 63 to 75% for each of the viruses, with an overall average of 68%. The ability of each concentration step, membrane filtration or organic flocculation, to recover the viruses from water was assayed. For the filtration step, although there were not large differences in virus recoveries from tap water, echovirus 7 was recovered with the lowest efficiency (72%), and poliovirus 1 was recovered with the highest (87%) efficiency. Overall virus recovery by the filtration step was least efficient for wastewater (73%) and most efficient for seawater (107%).(ABSTRACT TRUNCATED AT 250 WORDS)
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Berg G., Dahling D. R., Berman D. Recovery of small quantities of viruses from clean waters on cellulose nitrate membrane filters. Appl Microbiol. 1971 Oct;22(4):608–614. doi: 10.1128/am.22.4.608-614.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chang L. T., Farrah S. R., Bitton G. Positively charged filters for virus recovery from wastewater treatment plant effluents. Appl Environ Microbiol. 1981 Nov;42(5):921–924. doi: 10.1128/aem.42.5.921-924.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jakubowski W., Hill W. F., Jr, Clarke N. A. Comparative study of four microporous filters for concentrating viruses from drinking water. Appl Microbiol. 1975 Jul;30(1):58–65. doi: 10.1128/am.30.1.58-65.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Katzenelson E. A rapid method for quantitative assay of poliovirus from water with the aid of the fluorescent antibody technique. Arch Virol. 1976;50(3):197–206. doi: 10.1007/BF01320573. [DOI] [PubMed] [Google Scholar]
- Katzenelson E., Fattal B., Hostovesky T. Organic flocculation: an efficient second-step concentration method for the detection of viruses in tap water. Appl Environ Microbiol. 1976 Oct;32(4):638–639. doi: 10.1128/aem.32.4.638-639.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sobsey M. D., Gerba C. P., Wallis C., Melnick J. L. Concentration of enteroviruses from large volumes of turbid estuary water. Can J Microbiol. 1977 Jun;23(6):770–778. doi: 10.1139/m77-114. [DOI] [PubMed] [Google Scholar]
- Wallis C., Henderson M., Melnick J. L. Enterovirus concentration on cellulose membranes. Appl Microbiol. 1972 Mar;23(3):476–480. doi: 10.1128/am.23.3.476-480.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]
