Abstract
In the absence of food debris, m-FC agar counts of Escherichia coli on Oxoid Nuflow membrane filters (Oxoid Canada Inc., Nepean, Ontario, Canada) were lower than the corresponding surface plate counts. For seven food types tested, recovery of E. coli improved with increasing thickness of food debris on the membrane filter, and mats thicker than 0.5 micron protected the organism completely.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Brodsky M. H., Schiemann D. A. Influence of coliform source on evaluation of membrane filters. Appl Microbiol. 1975 Nov;30(5):727–730. doi: 10.1128/am.30.5.727-730.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Green B. L., Clausen E., Litsky W. Comparison of the new millipore HC with conventional membrane filters for the enumeration of fecal coliform bacteria. Appl Microbiol. 1975 Oct;30(4):697–699. doi: 10.1128/am.30.4.697-699.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Peterkin P. I., Sharpe A. N. Filtering out food debris before microbiological analysis. Appl Environ Microbiol. 1981 Jul;42(1):63–65. doi: 10.1128/aem.42.1.63-65.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Peterkin P. I., Sharpe A. N. Membrane filtration of dairy products for microbiological analysis. Appl Environ Microbiol. 1980 Jun;39(6):1138–1143. doi: 10.1128/aem.39.6.1138-1143.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sharpe A. N., Michaud G. L. Hydrophobic grid-membrane filters: new approach to microbiological enumeration. Appl Microbiol. 1974 Aug;28(2):223–225. doi: 10.1128/am.28.2.223-225.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sharpe A. N., Peterkin P. I., Dudas I. Membrane filtration of food suspensions. Appl Environ Microbiol. 1979 Jan;37(1):21–35. doi: 10.1128/aem.37.1.21-35.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sharpe A. N., Peterkin P. I., Malik N. Improved detection of coliforms and Escherichia coli in foods by a membrane filter method. Appl Environ Microbiol. 1979 Sep;38(3):431–435. doi: 10.1128/aem.38.3.431-435.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sharpe A. N., Peterkin P. I., Rayman M. K. Detection of Escherichia coli in foods: indole staining methods for cellulosic and polysulfone membrane filters. Appl Environ Microbiol. 1981 Jun;41(6):1310–1315. doi: 10.1128/aem.41.6.1310-1315.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Standridge J. H. Comparison of surface pore morphology of two brands of membrane filters. Appl Environ Microbiol. 1976 Feb;31(2):316–319. doi: 10.1128/aem.31.2.316-319.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tobin R. S., Dutka B. J. Comparison of the surface structure, metal binding, and fecal coliform recoveries of nine membrane filters. Appl Environ Microbiol. 1977 Jul;34(1):69–79. doi: 10.1128/aem.34.1.69-79.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tobin R. S., Lomax P., Kushner D. J. Comparison of nine brands of membrane filter and the most-probable-number methods for total coliform enumeration in sewage-contaminated drinking water. Appl Environ Microbiol. 1980 Aug;40(2):186–191. doi: 10.1128/aem.40.2.186-191.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
