Abstract
A technique is described for detecting and characterizing bacteria on a single-particle basis by mass spectrometry. The method involves generation of a particle beam of single whole cells which are rapidly volatilized and ionized in vacuum in the ion source of a quadrupole mass spectrometer. The particle beam can be generated, with minimal sample handling, from a naturally occurring aerosol or from a solution of bacteria that can be dispersed as an aerosol. The mass spectrum is generated by successively measuring the average intensities of different mass peaks. The average intensity is obtained by measuring the ion intensity distribution at the particular mass (m/e) for ion pulses from more than 1,000 bacteria particles. Bacillus cereus, Bacillus subtilis, and Pseudomonas putida samples were analyzed to test the capability of the instrument for differentiating among species of bacteria. Significant ion-intensity information was produced over the m/e range of 50 to 300, an improvement over previous pyrolysis-mass spectrometry results. The complex mass spectra contained a few unique peaks which could be used for the differentiation of the bacteria. A statistical analysis of the variations in peak intensities among the three bacteria provided a quantitative measure of the reproducibility of the instrument and its ability to differentiate among bacteria. The technique could lead to a new rapid method for the analysis of microorganisms and could be used for the detection of airborne pathogens on a continuous, real-time basis.
Full text
PDF







Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- CUMMINS C. S., HARRIS H. The chemical composition of the cell wall in some gram-positive bacteria and its possible value as a taxonomic character. J Gen Microbiol. 1956 Jul;14(3):583–600. doi: 10.1099/00221287-14-3-583. [DOI] [PubMed] [Google Scholar]
- Charnley J. Postoperative infection after total hip replacement with special reference to air contamination in the operating room. Clin Orthop Relat Res. 1972 Sep;87:167–187. doi: 10.1097/00003086-197209000-00020. [DOI] [PubMed] [Google Scholar]
- Cinkotai F. F., Lockwood M. G., Rylander R. Airborne micro-organisms and prevalence of byssinotic symptoms in cotton mills. Am Ind Hyg Assoc J. 1977 Oct;38(10):554–559. doi: 10.1080/0002889778507669. [DOI] [PubMed] [Google Scholar]
- Cronholm L. S. Potential health hazards from microbial aerosols in densely populated urban regions. Appl Environ Microbiol. 1980 Jan;39(1):6–12. doi: 10.1128/aem.39.1.6-12.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fraser D. W., Tsai T. R., Orenstein W., Parkin W. E., Beecham H. J., Sharrar R. G., Harris J., Mallison G. F., Martin S. M., McDade J. E. Legionnaires' disease: description of an epidemic of pneumonia. N Engl J Med. 1977 Dec 1;297(22):1189–1197. doi: 10.1056/NEJM197712012972201. [DOI] [PubMed] [Google Scholar]
- Katzenelson E., Buium I., Shuval H. I. Risk of communicable disease infection associated with wastewater irrigation in agricultural settlements. Science. 1976 Nov 26;194(4268):944–946. doi: 10.1126/science.982051. [DOI] [PubMed] [Google Scholar]
- Kleyn J. G., Johnson W. M., Wetzler T. F. Microbial aerosols and actinomycetes in etiological considerations of mushroom workers' lungs. Appl Environ Microbiol. 1981 Jun;41(6):1454–1460. doi: 10.1128/aem.41.6.1454-1460.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Meuzelaar H. L., Kistemaker P. G. A technique for fast and reproducible fingerprinting of bacteria by pyrolysis mass spectrometry. Anal Chem. 1973 Mar;45(3):587–590. doi: 10.1021/ac60325a051. [DOI] [PubMed] [Google Scholar]
- Schulten H. R., Beckey H. D., Meuzelaar H. L., Boerboom A. J. High resolution field ionization mass spectrometry of bacterial pyrolysis products. Anal Chem. 1973 Jan;45(1):191–195. [PubMed] [Google Scholar]
- Simmonds P. G. Whole microorganisms studied by pyrolysis-gas chromatography-mass spectrometry: significance for extraterrestrial life detection experiments. Appl Microbiol. 1970 Oct;20(4):567–572. doi: 10.1128/am.20.4.567-572.1970. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wieten G., Haverkamp J., Meuzelaar H. L., Engel H. W., Berwald L. G. Pyrolysis mass spectrometry: a new method to differentiate between the mycobacteria of the 'tuberculosis complex' and other mycobacteria. J Gen Microbiol. 1981 Jan;122(1):109–118. doi: 10.1099/00221287-122-1-109. [DOI] [PubMed] [Google Scholar]

