Skip to main content
Applied and Environmental Microbiology logoLink to Applied and Environmental Microbiology
. 1982 May;43(5):1001–1005. doi: 10.1128/aem.43.5.1001-1005.1982

Water-to-Air Transfer and Enrichment of Bacteria in Drops from Bursting Bubbles

Duncan C Blanchard 1, Lawrence D Syzdek 1
PMCID: PMC244176  PMID: 16346001

Abstract

An electrostatic induction technique was used to determine both drop size distribution and concentration of bacteria in the film drops produced by bubbles bursting at the surface of a suspension of Serratia marcescens. Film drops are produced from the collapse of the thin film of water that just before bursting separates the air in the bubble from the atmosphere. Bubbles of 1.7-mm diameter produced from 10 to 20 film drops which ranged from <2 μm to over 30 μm in diameter. Half the drops were <10 μm. For bubbles rising a distance of less than 2 cm through the bacterial suspension, bacterial enrichment factors in the drops were between 10 and 20. Electrostatic methods can be used to determine the enrichment of bacteria in film drops as a function of bubble size and distance of rise through the bacterial suspension.

Full text

PDF
1001

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Baylor E. R., Peters V., Baylor M. B. Water-to-air transfer of virus. Science. 1977 Aug 19;197(4305):763–764. doi: 10.1126/science.329413. [DOI] [PubMed] [Google Scholar]
  2. Blanchard D. C., Syzdek L. Mechanism for the water-to-air transfer and concentration of bacteria. Science. 1970 Nov 6;170(3958):626–628. doi: 10.1126/science.170.3958.626. [DOI] [PubMed] [Google Scholar]
  3. Dondero T. J., Jr, Rendtorff R. C., Mallison G. F., Weeks R. M., Levy J. S., Wong E. W., Schaffner W. An outbreak of Legionnaires' disease associated with a contaminated air-conditioning cooling tower. N Engl J Med. 1980 Feb 14;302(7):365–370. doi: 10.1056/NEJM198002143020703. [DOI] [PubMed] [Google Scholar]
  4. Hejkal T. W., Larock P. A., Winchester J. W. Water-to-Air Fractionation of Bacteria. Appl Environ Microbiol. 1980 Feb;39(2):335–338. doi: 10.1128/aem.39.2.335-338.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Wendt S. L., George K. L., Parker B. C., Gruft H., Falkinham J. O., 3rd Epidemiology of infection by nontuberculous Mycobacteria. III. Isolation of potentially pathogenic mycobacteria from aerosols. Am Rev Respir Dis. 1980 Aug;122(2):259–263. doi: 10.1164/arrd.1980.122.2.259. [DOI] [PubMed] [Google Scholar]