Skip to main content
Postgraduate Medical Journal logoLink to Postgraduate Medical Journal
. 1969 Aug;45(526):503–505. doi: 10.1136/pgmj.45.526.503

The use and limitations of isotope studies in clinical shock

M D A Vickers
PMCID: PMC2466882  PMID: 4898865

Abstract

Blood volume measurements can only be of value in the treatment of clinical shock if the results are obtained quickly. In a changing situation, such as continuing haemorrhage, erroneous conclusions are inevitable.

Assumptions which are commonly made concerning tracer loss rates and mixing rates may be invalid. Semi-automated machines can introduce new sources of error.

The measurement of blood volume should be regarded as an aid to assessing the relative contributions of intravascular volume and vascular tone to the resulting intravascular pressures.

Full text

PDF
503

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. ALLEN T. H., REEVE E. B. Distribution of extra plasma in the blood of some tissues in the dog of measured with P32 and T-1824. Am J Physiol. 1953 Nov;175(2):218–223. doi: 10.1152/ajplegacy.1953.175.2.218. [DOI] [PubMed] [Google Scholar]
  2. Birkeland S. The question of the reliability of blood volume determinations in severe pathological states where the circulation is unstable, possibly with manifest clinical shock. Acta Chir Scand Suppl. 1966;357:136–137. [PubMed] [Google Scholar]
  3. Brisman R., Parks L. C., Benson D. W. Pitfalls in the clinical use of central venous pressure. Arch Surg. 1967 Dec;95(6):902–907. doi: 10.1001/archsurg.1967.01330180050009. [DOI] [PubMed] [Google Scholar]
  4. Brozovic B., Korubin V., Lewis S. M., Szur L. Simultaneous red cell and plasma volume determinations by a differential absorption method. J Lab Clin Med. 1966 Jul;68(1):142–148. [PubMed] [Google Scholar]
  5. CHAPLIN H., Jr, MOLLISON P. L., VETTER H. The body/venous hematocrit ratio: its constancy over a wide hematocrit range. J Clin Invest. 1953 Dec;32(12):1309–1316. doi: 10.1172/JCI102859. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Fisk G. C., Bodlander F. M. Sampling for serial blood volume estimations in children. Med J Aust. 1967 Feb 4;1(5):221–222. doi: 10.5694/j.1326-5377.1967.tb21158.x. [DOI] [PubMed] [Google Scholar]
  7. GRABLE E., FINCK A. J., ABRAMS A. L., WILLIAMS J. A. The effect of cyclopropane and halothane on the blood volume in man. Anesthesiology. 1962 Nov-Dec;23:828–830. doi: 10.1097/00000542-196211000-00013. [DOI] [PubMed] [Google Scholar]
  8. HOPE A., VEREL D. Further observations on the distribution of red cells and plasma in disease; the low body haematocrit: venous haematocrit ratio. Clin Sci. 1955 Aug;14(3):501–507. [PubMed] [Google Scholar]
  9. Heath M. L., Vickers M. D. An examination of single-tracer, semi-automated blood volume methodology. Anaesthesia. 1968 Oct;23(4):659–669. doi: 10.1111/j.1365-2044.1968.tb00129.x. [DOI] [PubMed] [Google Scholar]
  10. Hoye R. C., Ketcham A. S., Berlin N. I. Total red cell and plasma volume alterations occurring with extensive surgery in humans. Surg Gynecol Obstet. 1966 Jul;123(1):27–34. [PubMed] [Google Scholar]
  11. KARLSON K. E., SENN L. Y. SIMULTANEOUS DETERMINATION OF RED CELL MASS AND PLASMA VOLUME WITH CR51 AND I131 USING A PULSE HEIGHT ANALYZER. Ann Surg. 1963 Aug;158:309–318. doi: 10.1097/00000658-196308000-00026. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. MacLean L. D. The clinical management of shock. Br J Anaesth. 1966 Apr;38(4):255–266. doi: 10.1093/bja/38.4.255. [DOI] [PubMed] [Google Scholar]
  13. Noble R. P., Gregersen M. I., Porter P. M., Buckman A. BLOOD VOLUME IN CLINICAL SHOCK. I. MIXING TIME AND DISAPPEARANCE RATE OF T-1824 IN NORMAL SUBJECTS AND IN PATIENTS IN SHOCK; DETERMINATION OF PLASMA VOLUME IN MAN FROM 10-MINUTE SAMPLE. J Clin Invest. 1946 Mar;25(2):158–171. doi: 10.1172/JCI101695. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. PAPPENHEIMER J. R., KINTER W. B. Hematocrit ratio of blood within mammalian kidney and its significance for renal hemodynamics. Am J Physiol. 1956 May;185(2):377–390. doi: 10.1152/ajplegacy.1956.185.2.377. [DOI] [PubMed] [Google Scholar]
  15. REEVE E. B., GREGERSEN M. I., ALLEN T. H., SEAR H. Distribution of cells and plasma in the normal and splenectomized dog and its influence on blood volume estimates with P32 and T-1824. Am J Physiol. 1953 Nov;175(2):195–203. doi: 10.1152/ajplegacy.1953.175.2.195. [DOI] [PubMed] [Google Scholar]
  16. REMINGTON J. W., BAKER C. H. Evaluation of blood volume measurement techniques. Circ Res. 1961 Jan;9:60–68. doi: 10.1161/01.res.9.1.60. [DOI] [PubMed] [Google Scholar]
  17. SMITH L. L., MOORE F. D. Refractory hypotension in man--is this irreversible shock? N Engl J Med. 1962 Oct 11;267:733–742. doi: 10.1056/NEJM196210112671501. [DOI] [PubMed] [Google Scholar]
  18. SUZUKI F., BAKER R. J., SHOEMAKER W. C. RED CELL AND PLASMA VOLUME ALTERATIONS AFTER HEMORRHAGE AND TRAUMA. Ann Surg. 1964 Aug;160:263–274. doi: 10.1097/00000658-196408000-00014. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Underwood P. S., Boyan C. P., Howland W. S. Appraisal of RISA blood volume for clinical use. Anesth Analg. 1966 Jan-Feb;45(1):1–8. [PubMed] [Google Scholar]
  20. VICK J. A., CIUCHTA H. P., MERICKEL J. H., LINDSETH E. O. VASODILATOR THERAPY IN ACUTE HEMORRHAGIC SHOCK. Circ Res. 1965 Jan;16:58–64. doi: 10.1161/01.res.16.1.58. [DOI] [PubMed] [Google Scholar]
  21. WEIL M. H., SHUBIN H., ROSOFF L. FLUID REPLETION IN CIRCULATORY SHOCK: CENTRAL VENOUS PRESSURE AND OTHER PRACTICAL GUIDES. JAMA. 1965 May 24;192:668–674. doi: 10.1001/jama.1965.03080210012003. [DOI] [PubMed] [Google Scholar]

Articles from Postgraduate Medical Journal are provided here courtesy of BMJ Publishing Group

RESOURCES