Abstract
The standardization of diagnostic immunofluorescence is a complex problem because diagnostic results are greatly influenced by interacting factors, such as the equipment, materials, and techniques for expressing and recording fluorescence. Furthermore, the characteristics of immunofluorescence reagents depend on how they are manufactured and used. The adoption of stable reference preparations of such reagents appears to be the only practicable way of standardizing laboratory test results. Several professional and regulatory organizations are actively promoting this objective. Consensus evaluation may be the best method of introducing proposed standards. Basic and applied research must provide the information needed to improve reagents and tests.
Material fluorescent standards are proving helpful in standardizing fluorescence emission, but the most promising development is the use of insolubilized antigens to provide standards for more relevant immunological-fluorescence comparisons.
Several important direct and indirect diagnostic immunofluorescence tests and reagents currently used in microbiological, histological, and pathological examinations require standardization. The medical profession should insist that commercial reagents be adequately characterized and that manufacturers supply the data necessary for their safe and informed use.
Full text
PDF









Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Aisenberg A. C., Bloch K. J. Immunoglobulins on the surface of neoplastic lymphocytes. N Engl J Med. 1972 Aug 10;287(6):272–276. doi: 10.1056/NEJM197208102870603. [DOI] [PubMed] [Google Scholar]
- Becker W. Determination of antisera titres ing the single radial immunodiffusion method. Immunochemistry. 1969 Jul;6(4):539–546. doi: 10.1016/0019-2791(69)90193-1. [DOI] [PubMed] [Google Scholar]
- Bergquist N. R., Holubar K., Diaz G. A., Beutner E. H. The manufacture of protein microspheres by suspension polymerization. Int Arch Allergy Appl Immunol. 1972;43(5):791–799. doi: 10.1159/000230895. [DOI] [PubMed] [Google Scholar]
- Beutner E. H. Field trials by ten laboratories of six commercial conjugates prepared from antisera to human IgG. Ann N Y Acad Sci. 1971 Jun 21;177:361–404. doi: 10.1111/j.1749-6632.1971.tb35066.x. [DOI] [PubMed] [Google Scholar]
- Brandtzaeg P. Evaluation of immunofluorescence with artificial sections of selected antigenicity. Immunology. 1972 Jan;22(1):177–183. [PMC free article] [PubMed] [Google Scholar]
- Camargo M. E., Ferreira A. W. A microscopic immunofluorescence technique with soluble protein antigens fixed to cellulose particles. Int Arch Allergy Appl Immunol. 1970;39(2-3):292–300. doi: 10.1159/000230355. [DOI] [PubMed] [Google Scholar]
- Cherry W. B., McKinney R. M., Emmel V. M., Spillane J. T., Herbert G. A., Pittman B. Evaluation of commercial fluorescein isothiocyanates used in fluorescent antibody studies. Stain Technol. 1969 Jul;44(4):179–186. doi: 10.3109/10520296909063347. [DOI] [PubMed] [Google Scholar]
- Faulk W. P., Hijmans W. Recent developments in immunofluorescence. Prog Allergy. 1972;16:9–39. doi: 10.1159/000393067. [DOI] [PubMed] [Google Scholar]
- Garratty G., Petz L. D. An evaluation of commercial antiglobulin sera with particular reference to their anticomplement properties. Transfusion. 1971 Mar-Apr;11(2):79–88. doi: 10.1111/j.1537-2995.1971.tb04381.x. [DOI] [PubMed] [Google Scholar]
- Good R. A. Lymphocyte surface markers. N Engl J Med. 1972 Aug 10;287(6):305–306. doi: 10.1056/NEJM197208102870614. [DOI] [PubMed] [Google Scholar]
- Hunter E. F., Smith J. F., Lewis J. S., McGrew B. E., Schmale J. D. Immunochemical parameters of some commercial conjugates for the fluorescent treponemal antibody-absorption test. Infect Immun. 1972 Jun;5(6):858–862. doi: 10.1128/iai.5.6.858-862.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jongsma A. P., Hijmans W., Ploem J. S. Quantitative immunofluorescence. Standardization and calibration in microfluorometry. Histochemie. 1971;25(4):329–343. doi: 10.1007/BF00278226. [DOI] [PubMed] [Google Scholar]
- Julian A. J., Logan L. C., Norins L. C. Early syphilis: immunoglobulins reactive in immunofluorescence and other serologic tests. J Immunol. 1969 May;102(5):1250–1259. [PubMed] [Google Scholar]
- Killander D., Levin A., Inoue M., Klein E. Quantification of immunofluorescence on individual erythrocytes coated with varying amounts of antigen. Immunology. 1970 Jul;19(1):151–156. [PMC free article] [PubMed] [Google Scholar]
- MCKINNEY R. M., SPILLANE J. T., PEARCE G. W. DETERMINATION OF PURITY OF FLUORESCEIN ISOTHIOCYANATES. Anal Biochem. 1964 Jan;7:74–86. doi: 10.1016/0003-2697(64)90121-6. [DOI] [PubMed] [Google Scholar]
- Mostratos A., Beswick T. S. Lack of specificity of some commercial antiglobulin conjugates in indirect immunofluorescence tests. J Pathol. 1969 May;98(1):1–16. doi: 10.1002/path.1710980102. [DOI] [PubMed] [Google Scholar]
- Peetoom F., Mulder C. Some results on an immunochemical analysis of fluorescein-conjugated antihuman IgM sera. J Pediatr. 1969 Dec;75(6):1125–1128. doi: 10.1016/s0022-3476(69)80367-7. [DOI] [PubMed] [Google Scholar]
- Phillips D. J., Shore S. L., Maddison S. E., Gordon D. S., Reimer C. B. Comparative evaluation of commercial precipitating antisera against human IgA. J Lab Clin Med. 1971 Apr;77(4):639–644. [PubMed] [Google Scholar]
- Reimer C. B., Phillips D. J., Maddison S. E., Shore S. L. Comparative evaluation of commercial precipitating antisera against human IgM and IgM. J Lab Clin Med. 1970 Dec;76(6):949–960. [PubMed] [Google Scholar]
- Reimer C. B. Standardization of immunoglobulin reagents. Health Lab Sci. 1972 Jul;9(3):178–184. [PubMed] [Google Scholar]
- Remington J. S. Antibody standards for antibodies. N Engl J Med. 1970 Aug 27;283(9):491–492. doi: 10.1056/NEJM197008272830918. [DOI] [PubMed] [Google Scholar]
- Rowe D. S. Introductory review: characteristics of sera and conjugates. Ann N Y Acad Sci. 1971 Jun 21;177:335–336. doi: 10.1111/j.1749-6632.1971.tb35062.x. [DOI] [PubMed] [Google Scholar]
- Shirodaria P. V., Fraser K. B., Stanford F. Secondary fluorescent staining of virus antigens by rheumatoid factor and fluorescein-conjugated anti-IgM. Ann Rheum Dis. 1973 Jan;32(1):53–57. doi: 10.1136/ard.32.1.53. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Shore S. L., Phillips D. J., Reimer C. B. Umbrella effect: pitfall in analysis of specificity of antisera to immunoglobulins. Immunochemistry. 1971 Jun;8(6):562–565. doi: 10.1016/0019-2791(71)90408-3. [DOI] [PubMed] [Google Scholar]
- van Dalen J. P., Knapp W., Ploem J. S. Microfluorometry on antigen-antibody interaction in immunofluorescence using antigens covalently bound to agarose beads. J Immunol Methods. 1973 Jun;2(4):383–392. doi: 10.1016/0022-1759(73)90004-5. [DOI] [PubMed] [Google Scholar]