Abstract
Unsterile needles and syringes may transmit blood-borne infectious agents such as HIV and hepatitis B virus. The emergence of these diseases as major public health concerns and the risk of nosocomial transmission has heightened interest in the development of single-use injection devices. WHO and UNICEF embarked on a programme to develop and introduce these devices in 1987. We report on a field trial in Karachi, Pakistan, of the SoloShot (SS) plastic disposable syringe, which has a metal clip in the syringe barrel to prevent second-time withdrawal of the plunger. A conventional disposable syringe (CS) was used as a comparison. We observed 48 vaccinators giving 2400 injections with the SS and 1440 with the CS; 98.7% of SS performed as designed. The average volume required per delivered dose was comparable for the two syringes and was delivered more quickly with SS. Training and experience had a small but statistically significant effect on several aspects of SS use. Vaccinators who indicated a syringe preference preferred SS on 7 out of 9 indicators. SS is safe and effective in preventing reuse and is easier and quicker to use than the CS. Vaccinators require little, if any, special training. It could directly replace disposable syringes in expanded programmes on immunization (EPI) in countries where use of unsterile disposable devices occurs or when sterilization is not practical.
Full text
PDF






Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Anderson D. C., Blower A. L., Packer J. M., Ganguli L. A. Preventing needlestick injuries. BMJ. 1991 Mar 30;302(6779):769–770. doi: 10.1136/bmj.302.6779.769. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Berkley S., Weeks M., Barenzi J. Immunisation and fear of AIDS. Lancet. 1990 Jan 6;335(8680):47–48. doi: 10.1016/0140-6736(90)90171-z. [DOI] [PubMed] [Google Scholar]
- Centers for Disease Control (CDC) Patient exposures to HIV during nuclear medicine procedures. MMWR Morb Mortal Wkly Rep. 1992 Aug 7;41(31):575–578. [PubMed] [Google Scholar]
- Gellert G. Prevention of nosocomial HIV infection in the Soviet Union--an international responsibility. N Engl J Med. 1990 Dec 27;323(26):1844–1845. doi: 10.1056/NEJM199012273232616. [DOI] [PubMed] [Google Scholar]
- Halsey N. A., Berry S., Carrasco P., de Quadros C., Martinez J., Arroyo J. J., España V. D., Duarte E., Huertas E., Cruz J. R. Field evaluation of a simplified unit-dose syringe for administration of measles vaccine. Rev Infect Dis. 1989 May-Jun;11 (Suppl 3):S631–S638. doi: 10.1093/clinids/11.supplement_3.s631. [DOI] [PubMed] [Google Scholar]
- Hansen M. E., Miller G. L., 3rd, Redman H. C., McIntire D. D. Needle-stick injuries and blood contacts during invasive radiologic procedures: frequency and risk factors. AJR Am J Roentgenol. 1993 May;160(5):1119–1122. doi: 10.2214/ajr.160.5.8470590. [DOI] [PubMed] [Google Scholar]
- Hersh B. S., Popovici F., Apetrei R. C., Zolotusca L., Beldescu N., Calomfirescu A., Jezek Z., Oxtoby M. J., Gromyko A., Heymann D. L. Acquired immunodeficiency syndrome in Romania. Lancet. 1991 Sep 14;338(8768):645–649. doi: 10.1016/0140-6736(91)91230-r. [DOI] [PubMed] [Google Scholar]
- Hu D. J., Kane M. A., Heymann D. L. Transmission of HIV, hepatitis B virus, and other bloodborne pathogens in health care settings: a review of risk factors and guidelines for prevention. World Health Organization. Bull World Health Organ. 1991;69(5):623–630. [PMC free article] [PubMed] [Google Scholar]
- Marmor M., Hartsock P. Self-destructing (non-reusable) syringes. Lancet. 1991 Aug 17;338(8764):438–439. doi: 10.1016/0140-6736(91)91054-x. [DOI] [PubMed] [Google Scholar]
- Rudin C., Nars P. W. Disposable syringes and needles for Romania. Lancet. 1991 May 25;337(8752):1289–1290. doi: 10.1016/0140-6736(91)92959-6. [DOI] [PubMed] [Google Scholar]
- Samuels M. E., Koop C. E., Hartsock P. I. Single-use syringes. N Engl J Med. 1991 Apr 4;324(14):996–997. doi: 10.1056/NEJM199104043241415. [DOI] [PubMed] [Google Scholar]
