An evaluation of the HemoCue for measuring haemoglobin in field studies in Jamaica.

M Hudson-Thomas 1, K C Bingham 1, W K Simmons 1
PMCID: PMC2486701  PMID: 8062400

Abstract

The HemoCue system utilizes the principle of oxidation of haemoglobin to hemiglobin by sodium nitrite and the subsequent conversion of hemiglobin to hemiglobinazide by sodium azide. The reagents for these reactions are contained within a small disposable microcuvette of approximately 10 microliters in volume. A venous or capillary sample is introduced into the microcuvette by capillary action and, after reaction with the reagents, the absorbance is read in the HemoCue photometer at 565 and 880 nm. The haemoglobin concentration is then displayed as a digital reading, in either g/dl or mmol/l in 15-45 seconds. We compared haemoglobin values obtained by the HemoCue system with those from the Coulter Counter S-Plus IV in 366 pregnant women in urban Jamaica, and found a highly significant correlation (r = 0.78, P < 0.01). However, because of the convenience and ease of use of this instrument and considering the relatively high cost, we recommend it for use only as a research tool in field studies where accurate and rapid haemoglobin determinations are required.

Full text

PDF

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Cohen A. R., Seidl-Friedman J. HemoCue system for hemoglobin measurement. Evaluation in anemic and nonanemic children. Am J Clin Pathol. 1988 Sep;90(3):302–305. doi: 10.1093/ajcp/90.3.302. [DOI] [PubMed] [Google Scholar]
  2. Johns W. L., Lewis S. M. Primary health screening by haemoglobinometry in a tropical community. Bull World Health Organ. 1989;67(6):627–633. [PMC free article] [PubMed] [Google Scholar]
  3. Simmons W. K., Gurney J. M. Nutritional anemia in the English-speaking Caribbean and Suriname. Am J Clin Nutr. 1982 Feb;35(2):327–337. doi: 10.1093/ajcn/35.2.327. [DOI] [PubMed] [Google Scholar]
  4. Stone J. E., Simmons W. K., Jutsum P. J., Gurney J. M. An evaluation of methods of screening for anaemia. Bull World Health Organ. 1984;62(1):115–120. [PMC free article] [PubMed] [Google Scholar]
  5. von Schenck H., Falkensson M., Lundberg B. Evaluation of "HemoCue," a new device for determining hemoglobin. Clin Chem. 1986 Mar;32(3):526–529. [PubMed] [Google Scholar]

Articles from Bulletin of the World Health Organization are provided here courtesy of World Health Organization

RESOURCES