Measurement of limb blood flow by electrical impedance plethysmography.

J M Porter, I D Swain, P G Shakespeare
PMCID: PMC2498042  PMID: 4004047

Abstract

Limb blood flow has been measured in 72 individuals by the noninvasive technique of electrical impedance plethysmography. Venous occlusion was not used. Blood flow was measured in 230 limbs in which 195 limbs were either in normal individuals or the clinically normal limbs of patients (normal limbs). Thirty-five limbs were clinically abnormal. Measurements on limbs with clinical abnormalities showed that blood flow values often fell within the limits of the normal range. However 3 cases of known vascular injury and 2 cases studied after hand surgery under tourniquet showed lowered blood flow values by comparison with the unaffected limb. A simultaneously recorded range of cardiac output and stroke volume measurements gave similar results to those obtained in a previous, unconnected study.

Full text

PDF
169

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. FORMEL P. F., DOYLE J. T. Rationale of venous occlusion plethysmography. Circ Res. 1957 Jul;5(4):354–356. doi: 10.1161/01.res.5.4.354. [DOI] [PubMed] [Google Scholar]
  2. Humphrey C. S., Leveson S. H., Wiggins P. A., Wilde D. T., Kester R. C. The evaluation of blood flow measurement using gravimetric plethysmograph. Br J Surg. 1980 Apr;67(4):242–246. doi: 10.1002/bjs.1800670405. [DOI] [PubMed] [Google Scholar]
  3. Kubicek W. G., Kottke J., Ramos M. U., Patterson R. P., Witsoe D. A., Labree J. W., Remole W., Layman T. E., Schoening H., Garamela J. T. The Minnesota impedance cardiograph- theory and applications. Biomed Eng. 1974 Sep;9(9):410–416. [PubMed] [Google Scholar]
  4. Mohapatra S. N., Arenson H. M. The measurement of peripheral blood flow by the electrical impedance technique. J Med Eng Technol. 1979 May;3(3):132–137. doi: 10.3109/03091907909162092. [DOI] [PubMed] [Google Scholar]
  5. Porter J. M., Shakespeare P. G. Cardiac output after burn injury. Ann R Coll Surg Engl. 1984 Jan;66(1):33–35. [PMC free article] [PubMed] [Google Scholar]
  6. WHITNEY R. J. The measurement of volume changes in human limbs. J Physiol. 1953 Jul;121(1):1–27. doi: 10.1113/jphysiol.1953.sp004926. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Annals of The Royal College of Surgeons of England are provided here courtesy of The Royal College of Surgeons of England

RESOURCES