Abstract
A new method of limb blood flow measurement has been developed; normal flow is 10-22 ml/100 ml of tissue/min and flow to limbs with claudication is 1.8-2.3. Does this technique help to deal with diagnostic problems in vascular surgery? Twenty-five patients presented with exercise-induced leg pain. Twelve had a convincing history of claudication but seven of these had palpable pedal pulses, the other five had normal Doppler ratios. Of 13 with a poor history six had absent pulses; of the other seven with palpable pulses, two had abnormal and five had normal Doppler ratios. All 25 patients have had blood flow to both legs measured. For the five with a poor history, palpable pulses and normal Doppler ratios: (Table: see text). Twelve had reduced flows consistent with claudication (less than 8 ml/100 ml of tissue/min); 10 of these have undergone arteriography which demonstrated significant vascular disease, one had surgery to rheumatoid toes deferred and one refused further investigation. Of 13 with normal flows nine have been found to have significant orthopaedic problems affecting spine, hips or knees, the other four have all had normal arteriograms. In every case the history, signs or Doppler ratios were potentially misleading, but all cases of significant arterial disease were detected. It is cheap, readily available and effectively selected cases for referral or arteriography.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Blankenhorn D. H., Curry P. J. The accuracy of arteriography and ultrasound imaging for atherosclerosis measurement. A review. Arch Pathol Lab Med. 1982 Oct;106(10):483–489. [PubMed] [Google Scholar]
- Campbell W. B., Wolfe J. H. The role of non-invasive tests in arterial disease. Br J Surg. 1987 Dec;74(12):1075–1076. doi: 10.1002/bjs.1800741203. [DOI] [PubMed] [Google Scholar]
- EVANS J. G. NEUROGENIC INTERMITTENT CLAUDICATION. Br Med J. 1964 Oct 17;2(5415):985–987. doi: 10.1136/bmj.2.5415.985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Giargiana F. A., Jr, Siegel M. E., James A. E., Jr, Rhodes B. A., Wagner H. N., Jr, White R. I., Jr A preliminary report on the complementary roles of arteriography and perfusion scanning in assessment of peripheral vascular disease. Radiology. 1973 Sep;108(3):619–627. doi: 10.1148/108.3.619. [DOI] [PubMed] [Google Scholar]
- Goodreau J. J., Creasy J. K., Flanigan P., Burnham S. J., Kudrna J. C., Schafer M. F., Bergan J. J., Yao J. S. Rational approach to the differentiation of vascular and neurogenic claudication. Surgery. 1978 Dec;84(6):749–757. [PubMed] [Google Scholar]
- Parkin A., Wiggins P. A., Robinson P. J., Vowden P., Kester R. C., Ware F. M. Use of a gamma camera for measuring limb blood flow in peripheral vascular disease. Br J Surg. 1987 Apr;74(4):271–274. doi: 10.1002/bjs.1800740415. [DOI] [PubMed] [Google Scholar]
- Schipper J., Kardaun J. W., Braakman R., van Dongen K. J., Blaauw G. Lumbar disk herniation: diagnosis with CT or myelography. Radiology. 1987 Oct;165(1):227–231. doi: 10.1148/radiology.165.1.3628775. [DOI] [PubMed] [Google Scholar]
- Smigiel M., Davis D. H. Pseudoclaudication. A review of etiology, diagnosis, and treatment. Clin Geriatr Med. 1985 May;1(2):373–380. [PubMed] [Google Scholar]
- Tait W. F., Charlesworth D., Lemon J. G. Atypical claudication. Br J Surg. 1985 Apr;72(4):315–316. doi: 10.1002/bjs.1800720425. [DOI] [PubMed] [Google Scholar]
- Wilkinson D., Vowden P., Parkin A., Wiggins P. A., Robinson P. J., Kester R. C. A reliable and readily available method of measuring limb blood flow in intermittent claudication. Br J Surg. 1987 Jun;74(6):516–519. doi: 10.1002/bjs.1800740633. [DOI] [PubMed] [Google Scholar]
- Yao S. T., Hobbs J. T., Irvine W. T. Ankle systolic pressure measurements in arterial disease affecting the lower extremities. Br J Surg. 1969 Sep;56(9):676–679. doi: 10.1002/bjs.1800560910. [DOI] [PubMed] [Google Scholar]