Skip to main content
Annals of The Royal College of Surgeons of England logoLink to Annals of The Royal College of Surgeons of England
. 1999 Jul;81(4):262–265.

Deterioration of theatre discipline during total joint replacement--have theatre protocols been abandoned?

P Madhavan 1, A Blom 1, B Karagkevrakis 1, M Pradeep 1, H Huma 1, J H Newman 1
PMCID: PMC2503261  PMID: 10615195

Abstract

The results of the Medical Research Council trial by Lidwell et al. in 1982 [Lidwell OM, Lowbury EJ, Whyte W et al. Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study. BMJ 1982; 285: 10-4] showed a decrease in infection rates following joint replacements carried out in ultraclean air theatres. Since then, the orthopaedic community in the UK has relied to a large extent on laminar airflow theatres to control infection following arthroplasty. At the same time, there has been a decline in the emphasis on basic principles and practices of antisepsis based on scientific evidence. We undertook this audit to establish whether published recommendations on theatre discipline were being followed in operating theatres where joint replacements are carried out, in England, Scotland and Wales. Our results show that with improvement in technology involved in clean air theatres, and availability in practice, slackness has crept into theatre protocol. In view of the fact that infection following arthroplasty has not been eliminated or indeed in some cases, maintained at the levels of the Medical Research Council study, we feel that traditional practices should be reintroduced. This study shows that there is pressing need for a set of recommendations on theatre practice for all staff in operating theatres that carry out joint replacements.

Full text

PDF
262

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Brown A. R., Taylor G. J., Gregg P. J. Air contamination during skin preparation and draping in joint replacement surgery. J Bone Joint Surg Br. 1996 Jan;78(1):92–94. [PubMed] [Google Scholar]
  2. Dineen P. Microbial filtration by surgical masks. Surg Gynecol Obstet. 1971 Nov;133(5):812–814. [PubMed] [Google Scholar]
  3. Hubble M. J., Weale A. E., Perez J. V., Bowker K. E., MacGowan A. P., Bannister G. C. Clothing in laminar-flow operating theatres. J Hosp Infect. 1996 Jan;32(1):1–7. doi: 10.1016/s0195-6701(96)90159-0. [DOI] [PubMed] [Google Scholar]
  4. Lidwell O. M., Lowbury E. J., Whyte W., Blowers R., Stanley S. J., Lowe D. Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study. Br Med J (Clin Res Ed) 1982 Jul 3;285(6334):10–14. doi: 10.1136/bmj.285.6334.10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Ritter M. A., Eitzen H., French M. L., Hart J. B. The operating room environment as affected by people and the surgical face mask. Clin Orthop Relat Res. 1975 Sep;(111):147–150. doi: 10.1097/00003086-197509000-00020. [DOI] [PubMed] [Google Scholar]
  6. Schaal K. P. Medical and microbiological problems arising from airborne infection in hospitals. J Hosp Infect. 1991 Jun;18 (Suppl A):451–459. doi: 10.1016/0195-6701(91)90056-E. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Taylor G. J., Bannister G. C. Infection and interposition between ultraclean air source and wound. J Bone Joint Surg Br. 1993 May;75(3):503–504. doi: 10.1302/0301-620X.75B3.8496233. [DOI] [PubMed] [Google Scholar]
  8. Thomas J. A., Fligelstone L. J., Jerwood T. E., Rees R. W. Theatre footwear: a health hazard? Br J Theatre Nurs. 1993 Oct;3(7):5-6, 9. [PubMed] [Google Scholar]