Abstract
We began implementation of a medical decision support system (MDSS) at the Columbia-Presbyterian Medical Center (CPMC) using the Arden Syntax in 1992. The Clinical Event Monitor which executes the Medical Logic Modules (MLMs) runs on a mainframe computer. Data are stored in a relational database and accessed via PL/I programs known as Data Access Modules (DAMs). Currently we have 18 clinical, 12 research and 10 administrative MLMs. On average, the clinical MLMs generate 50357 simple interpretations of laboratory data and 1080 alerts each month. The number of alerts actually read varies by subject of the MLM from 32.4% to 73.5%. Most simple interpretations are not read at all. A significant problem of MLMs is maintenance, and changes in laboratory testing and message output can impair MLM execution significantly. We are now using relational database technology and coded MLM output to study the process outcome of our MDSS.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Jenders R. A., Morgan M., Barnett G. O. Use of open standards to implement health maintenance guidelines in a clinical workstation. Comput Biol Med. 1994 Sep;24(5):385–390. doi: 10.1016/0010-4825(94)90006-x. [DOI] [PubMed] [Google Scholar]
- Johnston M. E., Langton K. B., Haynes R. B., Mathieu A. Effects of computer-based clinical decision support systems on clinician performance and patient outcome. A critical appraisal of research. Ann Intern Med. 1994 Jan 15;120(2):135–142. doi: 10.7326/0003-4819-120-2-199401150-00007. [DOI] [PubMed] [Google Scholar]