Abstract
OBJECTIVE: To derive a formula that defines the postvoid residual (PVR) urine volume more accurately in patients with prostatic gland enlargement. DESIGN: Prospective. SETTING: Department of Radiology, University of Ilorin Teaching Hospital, Ilorin. SUBJECT: Fifty-two consecutive patients with benign prostatic hyperplasia. The mean age was 64.98+/-9.57 years. METHOD: PVR urine was evaluated by ultrasonography. Each patient had two examinations, the first of which was with a full bladder and the second of which was immediately after voiding. Two orthogonal diameters were measured on each bladder section (longitudinal and transverse) in the supine position. Fifty-two paired sets of ultrasonic measurements were thus obtained. Catheterized postvoid urine residue was regarded as the gold standard. RESULTS: Using these measurements, an equation--[PVR(CUBIC)=374.057+(-196.94+V1)+(32.5539+V1(2))+(-1.1480+V1(3)) where V1=average of the length (L), width (T), and the anteroposterior distance on transverse section (Dt) of the postvoid urinary bladder]--more accurate than previously existing ones was obtained by cubic regression analysis. Mean ultrasound estimated volume was 220.51 ml as against 220.76 ml after catheterization. The mean difference was 0.25 ml (not significant, p<0.01) with 95% confidence interval of +/-10 ml. With this equation, the ultrasonographic residual urine volume showed a higher correlation coefficient with the catheterized volume at p<0.01 (Pearson r=0.982, r2=0.96) than previously defined formulas. The standard error of the mean was 5.11 ml (mean=220.5+/-190.4 ml). CONCLUSION: With the above equation, we consider conventional transabdominal ultrasonography a reliable method for assessing the residual urine volume in patients with benign prostatic hyperplasia. This equation, though complex when compared to some of the pre-existing formulas, can be integrated into the memory of modern ultrasound machines for easy and faster computation.
Full text
PDF





Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Akino H., Wada O., Miwa Y., Nakamura N., Gobara M., Suzuki Y., Isomatsu Y., Kanimoto Y., Okada K., Namikawa M. [Ultrasonographic assessment of intravesical urine volume]. Hinyokika Kiyo. 1990 Jun;36(6):655–660. [PubMed] [Google Scholar]
- Alnaif B., Drutz H. P. The accuracy of portable abdominal ultrasound equipment in measuring postvoid residual volume. Int Urogynecol J Pelvic Floor Dysfunct. 1999;10(4):215–218. doi: 10.1007/s001920050048. [DOI] [PubMed] [Google Scholar]
- Beacock C. J., Roberts E. E., Rees R. W., Buck A. C. Ultrasound assessment of residual urine. A quantitative method. Br J Urol. 1985 Aug;57(4):410–413. doi: 10.1111/j.1464-410x.1985.tb06299.x. [DOI] [PubMed] [Google Scholar]
- Bent A. E., Nahhas D. E., McLennan M. T. Portable ultrasound determination of urinary residual volume. Int Urogynecol J Pelvic Floor Dysfunct. 1997;8(4):200–202. doi: 10.1007/BF02765813. [DOI] [PubMed] [Google Scholar]
- Bis K. G., Slovis T. L. Accuracy of ultrasonic bladder volume measurement in children. Pediatr Radiol. 1990;20(6):457–460. doi: 10.1007/BF02075208. [DOI] [PubMed] [Google Scholar]
- Brunn J., Ruf G. Sonographische Zystometrie. Ein einfaches Verfahren zur Bestimmung des Restarns. Dtsch Med Wochenschr. 1980 Oct 24;105(43):1501–1503. doi: 10.1055/s-2008-1070900. [DOI] [PubMed] [Google Scholar]
- Coombes G. M., Millard R. J. The accuracy of portable ultrasound scanning in the measurement of residual urine volume. J Urol. 1994 Dec;152(6 Pt 1):2083–2085. doi: 10.1016/s0022-5347(17)32314-5. [DOI] [PubMed] [Google Scholar]
- Ding Y. Y., Sahadevan S., Pang W. S., Choo P. W. Clinical utility of a portable ultrasound scanner in the measurement of residual urine volume. Singapore Med J. 1996 Aug;37(4):365–368. [PubMed] [Google Scholar]
- Espuela Orgaz R., Zuluaga Gomez A., Torres Ramirez C., Martinez Torres J. L. Applications of bladder ultrasonography. I. Bladder content and residue. J Urol. 1981 Feb;125(2):174–176. doi: 10.1016/s0022-5347(17)54952-6. [DOI] [PubMed] [Google Scholar]
- Fuse H., Yokoyama T., Muraishi Y., Katayama T. Measurement of residual urine volume using a portable ultrasound instrument. Int Urol Nephrol. 1996;28(5):633–637. doi: 10.1007/BF02552157. [DOI] [PubMed] [Google Scholar]
- Granados E. A., Escobar M. R., Alcahe R. Utilidad del ultrasonido transabdominal en la estimación del residuo postmiccional. Arch Esp Urol. 1998 Jun;51(5):473–476. [PubMed] [Google Scholar]
- Hakenberg O. W., Ryall R. L., Langlois S. L., Marshall V. R. The estimation of bladder volume by sonocystography. J Urol. 1983 Aug;130(2):249–251. doi: 10.1016/s0022-5347(17)51087-3. [DOI] [PubMed] [Google Scholar]
- Haylen B. T., Frazer M. I., Sutherst J. R., West C. R. Transvaginal ultrasound in the assessment of bladder volumes in women. Preliminary report. Br J Urol. 1989 Feb;63(2):149–151. doi: 10.1111/j.1464-410x.1989.tb05152.x. [DOI] [PubMed] [Google Scholar]
- Haylen B. T., Parys B. T., West C. R. Transrectal ultrasound to measure bladder volumes in men. J Urol. 1990 Apr;143(4):687–689. doi: 10.1016/s0022-5347(17)40060-7. [DOI] [PubMed] [Google Scholar]
- Haylen B. T. Verification of the accuracy and range of transvaginal ultrasound in measuring bladder volumes in women. Br J Urol. 1989 Oct;64(4):350–352. doi: 10.1111/j.1464-410x.1989.tb06040.x. [DOI] [PubMed] [Google Scholar]
- Hiraoka M., Tsukahara H., Tsuchida S., Hori C., Sudo M. Ultrasonographic evaluation of bladder volume in children. Pediatr Nephrol. 1993 Oct;7(5):533–535. doi: 10.1007/BF00852537. [DOI] [PubMed] [Google Scholar]
- Ireton R. C., Krieger J. N., Cardenas D. D., Williams-Burden B., Kelly E., Souci T., Chapman W. H. Bladder volume determination using a dedicated, portable ultrasound scanner. J Urol. 1990 May;143(5):909–911. doi: 10.1016/s0022-5347(17)40133-9. [DOI] [PubMed] [Google Scholar]
- Kiely E. A., Hartnell G. G., Gibson R. N., Williams G. Measurement of bladder volume by real-time ultrasound. Br J Urol. 1987 Jul;60(1):33–35. doi: 10.1111/j.1464-410x.1987.tb09128.x. [DOI] [PubMed] [Google Scholar]
- Knorr H., Strauss I., Seichert N. Sonographische Zystometrie unter Berücksichtigung der Harnblasenform und der Harnblasenfüllung. Ultraschall Med. 1990 Jun;11(3):150–154. doi: 10.1055/s-2007-1011551. [DOI] [PubMed] [Google Scholar]
- McLean G. K., Edell S. L. Determination of bladder volumes by gray scale ultrasonography. Radiology. 1978 Jul;128(1):181–182. doi: 10.1148/128.1.181. [DOI] [PubMed] [Google Scholar]
- Memon A., Ather M. H. Use of residual fraction instead of residual volume in the evaluation of lower urinary tract symptoms. Tech Urol. 2000 Mar;6(1):26–28. [PubMed] [Google Scholar]
- Milakovic M., Eggertsen R. Skonsamt och säkert att mäta residualurin med ultraljud. Lakartidningen. 1999 Jan 6;96(1-2):47–48. [PubMed] [Google Scholar]
- Nishizawa O., Matsuzaki A., Kohama T., Suzuki T., Noto H. Noninvasive screening procedure for evaluation of bladder emptying function. Tohoku J Exp Med. 1985 Dec;147(4):421–425. doi: 10.1620/tjem.147.421. [DOI] [PubMed] [Google Scholar]
- Paltieli Y., Degani S., Aharoni A., Shapiro I., Reiter A., Scharf M., Weiss A. Ultrasound assessment of the bladder volume after anterior colporrhaphy. Gynecol Obstet Invest. 1989;28(4):209–211. doi: 10.1159/000293580. [DOI] [PubMed] [Google Scholar]
- Pedersen J. F., Bartrum R. J., Grytter C. Residual urine determination by ultrasonic scanning. Am J Roentgenol Radium Ther Nucl Med. 1975 Oct;125(2):474–478. doi: 10.2214/ajr.125.2.474. [DOI] [PubMed] [Google Scholar]
- Poston G. J., Joseph A. E., Riddle P. R. The accuracy of ultrasound in the measurement of changes in bladder volume. Br J Urol. 1983 Aug;55(4):361–363. doi: 10.1111/j.1464-410x.1983.tb03322.x. [DOI] [PubMed] [Google Scholar]
- Rageth J. C., Langer K. Sonographische Restharnbestimmung. Urologe A. 1983 Mar;22(2):87–90. [PubMed] [Google Scholar]
- Richter S., Hag'ag R., Shalev M., Nissenkorn I. [Measuring residual urine by portable ultrasound scanner]. Harefuah. 1999 Aug;137(3-4):93-5, 176, 175. [PubMed] [Google Scholar]
- Simforoosh N., Dadkhah F., Hosseini S. Y., Asgari M. A., Nasseri A., Safarinejad M. R. Accuracy of residual urine measurement in men: comparison between real-time ultrasonography and catheterization. J Urol. 1997 Jul;158(1):59–61. doi: 10.1097/00005392-199707000-00016. [DOI] [PubMed] [Google Scholar]