Skip to main content
Journal of the National Medical Association logoLink to Journal of the National Medical Association
. 1976 Jul;68(4):281–284.

Cardiac output measurement: a comparison of direct Fick, dye dilution and thermodilution methods in stable and acutely Ill patients.

K Venkataraman, M F De Guzman, A Hafeez Khan, L J Haywood
PMCID: PMC2609555  PMID: 787547

Full text

PDF
281

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Cournand A., Ranges H. A., Riley R. L. COMPARISON OF RESULTS OF THE NORMAL BALLISTOCARDIOGRAM AND A DIRECT FICK METHOD IN MEASURING THE CARDIAC OUTPUT IN MAN. J Clin Invest. 1942 May;21(3):287–294. doi: 10.1172/JCI101302. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. FEGLER G. Measurement of cardiac output in anaesthetized animals by a thermodilution method. Q J Exp Physiol Cogn Med Sci. 1954;39(3):153–164. doi: 10.1113/expphysiol.1954.sp001067. [DOI] [PubMed] [Google Scholar]
  3. Forrester J. S., Ganz W., Diamond G., McHugh T., Chonette D. W., Swan H. J. Thermodilution cardiac output determination with a single flow-directed catheter. Am Heart J. 1972 Mar;83(3):306–311. doi: 10.1016/0002-8703(72)90429-2. [DOI] [PubMed] [Google Scholar]
  4. Ganz W., Donoso R., Marcus H. S., Forrester J. S., Swan H. J. A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol. 1971 Apr;27(4):392–396. doi: 10.1016/0002-9149(71)90436-x. [DOI] [PubMed] [Google Scholar]
  5. HAMILTON W. F., RILEY R. L. Comparison of the Fick and dye injection methods of measuring the cardiac output in man. Am J Physiol. 1948 May 1;153(2):309–321. doi: 10.1152/ajplegacy.1948.153.2.309. [DOI] [PubMed] [Google Scholar]
  6. MILLER D. E., GLEASON W. L., McINTOSH H. D. A comparison of the cardiac output determination by the direct Fick method and the dye-dilution method using indocyanine green dye and a cuvette densitometer. J Lab Clin Med. 1962 Feb;59:345–350. [PubMed] [Google Scholar]
  7. Smith H. J., Oriol A., Morch J., McGregor M. Hemodynamic studies in cardiogenic shock. Treatment with isoproterenol and metaraminol. Circulation. 1967 Jun;35(6):1084–1091. doi: 10.1161/01.cir.35.6.1084. [DOI] [PubMed] [Google Scholar]
  8. Weisel R. D., Berger R. L., Hechtman H. B. Current concepts measurement of cardiac output by thermodilution. N Engl J Med. 1975 Mar 27;292(13):682–684. doi: 10.1056/NEJM197503272921307. [DOI] [PubMed] [Google Scholar]

Articles from Journal of the National Medical Association are provided here courtesy of National Medical Association