Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1993 Mar;31(3):734–735. doi: 10.1128/jcm.31.3.734-735.1993

Effectiveness of resins in removing antibiotics from blood cultures.

O Crepin 1, M Roussel-Delvallez 1, G R Martin 1, R J Courcol 1
PMCID: PMC262858  PMID: 8458976

Abstract

The present study evaluates the effectiveness of BACTEC NR-26A resin-containing medium in removing eight antibiotics from blood cultures. Peak concentrations achievable clinically were chosen. All antibiotics were prepared in fresh human blood samples. Blood samples were obtained prior to and at 15 min and 2, 24, 48, and 72 h after inoculation. Aztreonam, ceftriaxone, imipenem, teicoplanin, and ticarcillin were partially removed from blood cultures.

Full text

PDF
734

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Courcol R. J., Durocher A. V., Roussel-Delvallez M., Fruchart A., Martin G. R. Routine evaluation of BACTEC NR-16A and NR-17A media. J Clin Microbiol. 1988 Sep;26(9):1619–1622. doi: 10.1128/jcm.26.9.1619-1622.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. DeGirolami P. C., Eichelberger K., Siegel J. Detection of bacteremia with the BACTEC 16B resin blood culture medium. Am J Clin Pathol. 1984 May;81(5):643–646. doi: 10.1093/ajcp/81.5.643. [DOI] [PubMed] [Google Scholar]
  3. Lindsey N. J., Riely P. E. In vitro antibiotic removal and bacterial recovery from blood with an antibiotic removal device. J Clin Microbiol. 1981 Mar;13(3):503–507. doi: 10.1128/jcm.13.3.503-507.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Rodriguez F., Lorian V. Antibacterial activity in blood cultures. J Clin Microbiol. 1985 Feb;21(2):262–263. doi: 10.1128/jcm.21.2.262-263.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Strand C. L. Evaluation of the antimicrobial removal device when used with the BACTEC blood culture system. Am J Clin Pathol. 1982 Dec;78(6):853–856. doi: 10.1093/ajcp/78.6.853. [DOI] [PubMed] [Google Scholar]
  6. Tegtmeier B. R., Vice J. L. Evaluation of the BACTEC 16B medium in a cancer center. Am J Clin Pathol. 1984 Jun;81(6):783–786. doi: 10.1093/ajcp/81.6.783. [DOI] [PubMed] [Google Scholar]
  7. Weinstein M. P., Mirrett S., Wilson M. L., Harrell L. J., Stratton C. W., Reller L. B. Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles. J Clin Microbiol. 1991 May;29(5):879–882. doi: 10.1128/jcm.29.5.879-882.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Wright A. J., Thompson R. L., McLimans C. A., Wilson W. R., Washington J. A., 2nd The antimicrobial removal device. A microbiological and clinical evaluation. Am J Clin Pathol. 1982 Aug;78(2):173–177. doi: 10.1093/ajcp/78.2.173. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES