Abstract
Accurate quantitation of pathogens and antibody concentrations in secretions has been difficult because of unpredictable dilution of secretion with th diluent at the time of sample collection. We added an inert substance, lithium chloride (LiCl), to the sample diluent and measured its concentration with an atomic absorption spectrometer before and after the specimen was added. LiCl, at a concentration of 2 mmol of Li per liter, has no negative effect on the survival of common respiratory pathogens or on the results of immunoassays. The method is applicable to any sample collecting in which dilution of the specimen is necessary.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Frasch C. E., Gotschlich E. C. An outer membrane protein of Neisseria meningitidis group B responsible for serotype specificity. J Exp Med. 1974 Jul 1;140(1):87–104. doi: 10.1084/jem.140.1.87. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Garcia-Bustos J. F., Tomasz A. Teichoic acid-containing muropeptides from Streptococcus pneumoniae as substrates for the pneumococcal autolysin. J Bacteriol. 1987 Feb;169(2):447–453. doi: 10.1128/jb.169.2.447-453.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hughes E. C., Johnson R. L. Circadian and interpersonal variability of IgA in nasal secretions. Ann Otol Rhinol Laryngol. 1973 Mar-Apr;82(2):216–222. doi: 10.1177/000348947308200221. [DOI] [PubMed] [Google Scholar]
- Jalonen E., Paton J. C., Koskela M., Kerttula Y., Leinonen M. Measurement of antibody responses to pneumolysin--a promising method for the presumptive aetiological diagnosis of pneumococcal pneumonia. J Infect. 1989 Sep;19(2):127–134. doi: 10.1016/s0163-4453(89)91864-1. [DOI] [PubMed] [Google Scholar]
- Lee W. H., McClain D. Improved Listeria monocytogenes selective agar. Appl Environ Microbiol. 1986 Nov;52(5):1215–1217. doi: 10.1128/aem.52.5.1215-1217.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lorin M. I., Gaerlan P. F., Mandel I. D. Quantitative composition of nasal secretions in normal subjects. J Lab Clin Med. 1972 Aug;80(2):275–281. [PubMed] [Google Scholar]
- Mygind N., Weeke B., Ullman S. Quantitative determination of immunoglobulins in nasal secretion. Int Arch Allergy Appl Immunol. 1975;49(1-2):99–107. doi: 10.1159/000231383. [DOI] [PubMed] [Google Scholar]
- Prellner K., Stjernquist-Desatnik A. A simple method for collecting nasopharyngeal secretions, using cross-linked dextran. Clin Otolaryngol Allied Sci. 1985 Apr;10(2):85–87. doi: 10.1111/j.1365-2273.1985.tb01172.x. [DOI] [PubMed] [Google Scholar]
- Sørensen C. H. Secretory IgA enzyme immunoassay. Application of a model for computation of the standard curve. Scand J Clin Lab Invest. 1982 Nov;42(7):577–583. doi: 10.1080/00365518209168133. [DOI] [PubMed] [Google Scholar]
- Waris M., Ziegler T., Kivivirta M., Ruuskanen O. Rapid detection of respiratory syncytial virus and influenza A virus in cell cultures by immunoperoxidase staining with monoclonal antibodies. J Clin Microbiol. 1990 Jun;28(6):1159–1162. doi: 10.1128/jcm.28.6.1159-1162.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]