Escherichia coli O157:H7 generates a unique biochemical profile on MicroScan conventional gram-negative identification panels.

S L Abbott 1, D F Hanson 1, T D Felland 1, S Connell 1, A H Shum 1, J M Janda 1
PMCID: PMC263131  PMID: 8195398

Abstract

More than 90% of the strains of Escherichia coli O157:H7 that were identified on a MicroScan gram-negative dried conventional (overnight) panel gave one of two unique biochemical profile numbers that were not detected in other d-sorbitol-negative E. coli or in other strains isolated from pathogenic processes. This suggests that the panel has the capability of being used as a preliminary screening tool for O157:H7 strains involved in hemorrhagic colitis when MacConkey-sorbitol agar is not available.

Full text

PDF
823

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Farmer J. J., 3rd, Davis B. R. H7 antiserum-sorbitol fermentation medium: a single tube screening medium for detecting Escherichia coli O157:H7 associated with hemorrhagic colitis. J Clin Microbiol. 1985 Oct;22(4):620–625. doi: 10.1128/jcm.22.4.620-625.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Griffin P. M., Tauxe R. V. The epidemiology of infections caused by Escherichia coli O157:H7, other enterohemorrhagic E. coli, and the associated hemolytic uremic syndrome. Epidemiol Rev. 1991;13:60–98. doi: 10.1093/oxfordjournals.epirev.a036079. [DOI] [PubMed] [Google Scholar]
  3. Karmali M. A. Infection by verocytotoxin-producing Escherichia coli. Clin Microbiol Rev. 1989 Jan;2(1):15–38. doi: 10.1128/cmr.2.1.15. [DOI] [PMC free article] [PubMed] [Google Scholar]