Abstract
Directigen FLU-A, a new enzyme immunoassay membrane test, rapidly detects influenza A virus antigen in specimens from patients. Nasopharyngeal washes and pharyngeal gargles were used to determine the effectiveness of the assay as applied to different types of routinely collected clinical samples. All specimens had been previously shown to contain influenza A virus by virus isolation in tissue culture. Directigen FLU-A was 90% sensitive (95% confidence interval, 56 to 99.7%) with nasopharyngeal washes but only 39% sensitive (95% confidence interval, 17 to 64%) with pharyngeal gargles (P = 0.018) when used with samples containing similar amounts of infectious virus (50% tissue culture infective dose, 1.0 to 4.5). The intensity of the positive reaction with Directigen FLU-A did not correlate with the amount of virus in the specimens. Directigen FLU-A was found to detect cell-associated antigen more readily than free virus; only 20 infected cells were required to identify cell-associated influenza A virus antigen, whereas the limit of detection for free virus was 1.63 x 10(3) infectious virus particles. These findings suggest that Directigen FLU-A detects the cell-associated antigen present in clinical specimens rather than free virus. In addition, Directigen FLU-A detected avian and swine influenza A viruses in both cloacal swabs (75% sensitivity) and swine lung homogenates (86% sensitivity), indicating its potential usefulness in the surveillance of nonhuman influenza A viruses.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Espy M. J., Smith T. F., Harmon M. W., Kendal A. P. Rapid detection of influenza virus by shell vial assay with monoclonal antibodies. J Clin Microbiol. 1986 Oct;24(4):677–679. doi: 10.1128/jcm.24.4.677-679.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Grandien M., Pettersson C. A., Gardner P. S., Linde A., Stanton A. Rapid viral diagnosis of acute respiratory infections: comparison of enzyme-linked immunosorbent assay and the immunofluorescence technique for detection of viral antigens in nasopharyngeal secretions. J Clin Microbiol. 1985 Nov;22(5):757–760. doi: 10.1128/jcm.22.5.757-760.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Harmon M. W., Pawlik K. M. Enzyme immunoassay for direct detection of influenza type A and adenovirus antigens in clinical specimens. J Clin Microbiol. 1982 Jan;15(1):5–11. doi: 10.1128/jcm.15.1.5-11.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lui K. J., Kendal A. P. Impact of influenza epidemics on mortality in the United States from October 1972 to May 1985. Am J Public Health. 1987 Jun;77(6):712–716. doi: 10.2105/ajph.77.6.712. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McQuillin J., Madeley C. R., Kendal A. P. Monoclonal antibodies for the rapid diagnosis of influenza A and B virus infections by immunofluorescence. Lancet. 1985 Oct 26;2(8461):911–914. doi: 10.1016/s0140-6736(85)90849-9. [DOI] [PubMed] [Google Scholar]
- Sarkkinen H. K., Halonen P. E., Salmi A. A. Detection of influenza A virus by radioimmunoassay and enzyme-immunoassay from nasopharyngeal specimens. J Med Virol. 1981;7(3):213–220. doi: 10.1002/jmv.1890070305. [DOI] [PubMed] [Google Scholar]
- Waner J. L., Todd S. J., Shalaby H., Murphy P., Wall L. V. Comparison of Directigen FLU-A with viral isolation and direct immunofluorescence for the rapid detection and identification of influenza A virus. J Clin Microbiol. 1991 Mar;29(3):479–482. doi: 10.1128/jcm.29.3.479-482.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Waner J. L., Whitehurst N. J., Todd S. J., Shalaby H., Wall L. V. Comparison of directigen RSV with viral isolation and direct immunofluorescence for the identification of respiratory syncytial virus. J Clin Microbiol. 1990 Mar;28(3):480–483. doi: 10.1128/jcm.28.3.480-483.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]