Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1992 Aug;30(8):2033–2037. doi: 10.1128/jcm.30.8.2033-2037.1992

Haemophilus influenzae ATCC 49766, an alternative quality control strain for monitoring broth microdilution susceptibility tests with selected beta-lactams.

A L Barry 1, J H Jorgensen 1, D J Hardy 1, S D Allen 1, C N Baker 1
PMCID: PMC265437  PMID: 1500511

Abstract

A beta-lactamase-negative, ampicillin-resistant strain of Haemophilus influenzae is currently used for quality control of broth microdilution tests performed with Haemophilus test medium (HTM). Studies with eight lots of HTM broth documented the fact that MIC limits for some antimicrobial agents are unrealistically stringent; i.e., only three of eight lots of HTM broth were satisfactory for testing cefaclor. An alternative, ampicillin-susceptible strain of H. influenzae (ATCC 49766) was found to provide much more reproducible results with five problematic drugs (cefaclor, cefuroxime, cefamandole, loracarbef, and cefonicid). Multilaboratory studies defined MIC control limits for both control strains tested against 12 antimicrobial agents.

Full text

PDF
2033

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Doern G. V., Gerlach E. H., Jorgensen J. H., Murray P. R., Thornsberry C., Washington J. A., Jr Quality control limits for disk diffusion and broth microdilution susceptibility tests with Haemophilus test medium. Diagn Microbiol Infect Dis. 1991 Nov-Dec;14(6):485–493. doi: 10.1016/0732-8893(91)90004-y. [DOI] [PubMed] [Google Scholar]
  2. Doern G. V., Jorgensen J. H., Thornsberry C., Snapper H. Disk diffusion susceptibility testing of Haemophilus influenzae using haemophilus test medium. Eur J Clin Microbiol Infect Dis. 1990 May;9(5):329–336. doi: 10.1007/BF01973739. [DOI] [PubMed] [Google Scholar]
  3. Jorgensen J. H., Redding J. S., Maher L. A., Howell A. W. Improved medium for antimicrobial susceptibility testing of Haemophilus influenzae. J Clin Microbiol. 1987 Nov;25(11):2105–2113. doi: 10.1128/jcm.25.11.2105-2113.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Mendelman P. M., Wiley E. A., Stull T. L., Clausen C., Chaffin D. O., Onay O. Problems with current recommendations for susceptibility testing of Haemophilus influenzae. Antimicrob Agents Chemother. 1990 Aug;34(8):1480–1484. doi: 10.1128/aac.34.8.1480. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)