Abstract
The accuracy and reproducibility of antibody levels obtained by single radial hemolysis with six internal reference sera were evaluated. The test was performed in a clinical laboratory for routine assessment of immunity to rubella infection over a period of 1 year. A linear relationship exists between the antibody titer (expressed in log dilution) and zone diameters. In 43 of 44 test runs the correlation coefficient of the standard curve was over 0.990. Prediction limits of 95% around the curve showed that on replication of the test, zone diameters could be found within less than half a doubling-dilution step. The antibody level can thus be determined more accurately by the single radial hemolysis test than in the conventional hemagglutination inhibition test. This is particularly important in assessing immunity when antibody titers are low, since the hemagglutination inhibition test is less reliable then. The use of standard sera calibrated international units would render results of different laboratories comparable and allow standardization at threshold values.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Champsaur H., Dussaix E., Tournier P. Hemagglutination inhibition, single radial hemolysis, and ELISA tests for the detection of IgG and IgM to rubella virus. J Med Virol. 1980;5(4):273–286. doi: 10.1002/1096-9071(1980)5:4<273::aid-jmv1890050403>3.0.co;2-j. [DOI] [PubMed] [Google Scholar]
- Enders G., Knotek F., Pacher U. Comparison of various serological methods and diagnostic kits for the detection of acute, recent, and previous rubella infection, vaccination, and congenital infections. J Med Virol. 1985 Jul;16(3):219–232. doi: 10.1002/jmv.1890160303. [DOI] [PubMed] [Google Scholar]
- Forsgren M., Sörén L. Subclinical rubella reinfection in vaccinated women with rubella-specific IgM response during pregnancy and transmission of virus to the fetus. Scand J Infect Dis. 1985;17(4):337–341. doi: 10.3109/13813458509058772. [DOI] [PubMed] [Google Scholar]
- Grillner L., Forsgren M., Nordenfelt E. Comparison between a commercial ELISA, Rubazyme, and hemolysis-in-gel test for determination of rubella antibodies. J Virol Methods. 1985 Feb;10(2):111–115. doi: 10.1016/0166-0934(85)90096-5. [DOI] [PubMed] [Google Scholar]
- Harnett G. B., Palmer C. A., Mackay-Scollay E. M. Single-radial-hemolysis test for the assay of rubella antibody in antenatal, vaccinated, and rubella virus-infected patients. J Infect Dis. 1979 Dec;140(6):937–944. doi: 10.1093/infdis/140.6.937. [DOI] [PubMed] [Google Scholar]
- Kurtz J. B., Mortimer P. P., Mortimer P. R., Morgan-Capner P., Shafi M. S., White G. B. Rubella antibody measured by radial haemolysis. Characteristics and performance of a simple screening method for use in diagnostic laboratories. J Hyg (Lond) 1980 Apr;84(2):213–222. doi: 10.1017/s0022172400026711. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Neumann P. W., Weber J. M. Single radial hemolysis test for rubella immunity and recent infection. J Clin Microbiol. 1983 Jan;17(1):28–34. doi: 10.1128/jcm.17.1.28-34.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Preblud S. R. Some current issues relating to rubella vaccine. JAMA. 1985 Jul 12;254(2):253–256. [PubMed] [Google Scholar]
- Reed S. E., Gardner P. S., Stanton J. United Kingdom scheme for external quality assessment in virology. Part II. Specimen distribution, performance assessment, and analyses of participants' methods in detection of rubella antibody, hepatitis B markers, general virus serology, virus identification, and electron microscopy. J Clin Pathol. 1985 May;38(5):542–553. doi: 10.1136/jcp.38.5.542. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Skaug K., Ulstrup J. C., Stray-Pedersen B. A rubella epidemic in an unvaccinated pregnant population. I. Screening methods and serological results. Scand J Infect Dis. 1981;13(1):11–15. doi: 10.1080/00365548.1981.11690360. [DOI] [PubMed] [Google Scholar]