Abstract
Modified procedures for the Sceptor Gram-Positive MIC Panel and the Vitek AutoMicrobic System GPS-M Card were evaluated for their ability to detect methicillin-resistant (heteroresistant) Staphylococcus aureus. A total of 398 clinical isolates (including 222 methicillin-resistant S. aureus) obtained from 10 hospitals were tested. Both systems had 2% NaCl in the oxacillin wells. Sceptor MIC panels were inoculated with an organism suspension prepared from an 18- to 24-h blood agar plate and were inoculated for a full 24 h at 35 degrees C before MICs were read. All methicillin-resistant S. aureus isolates were detected as resistant to oxacillin at greater than or equal to 8 micrograms/ml by the Sceptor method and at greater than 2 micrograms/ml by the Vitek method. All 176 oxacillin-susceptible, methicillin-susceptible S. aureus isolates were correctly distinguished from methicillin-resistant S. aureus isolates by Sceptor. However, with the Vitek system 29 methicillin-susceptible S. aureus isolates tested as falsely resistant to oxacillin and four isolates tested as falsely resistant to vancomycin. The modified testing procedure with the Sceptor system can be used reliably for accurate susceptibility testing of methicillin-resistant and methicillin-susceptible S. aureus. The Vitek GPS-M card does not accurately discriminate between methicillin-resistant and methicillin-susceptible S. aureus with an oxacillin breakpoint of greater than 2 micrograms/ml.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Aldridge K. E., Janney A., Sanders C. V., Marier R. L. Interlaboratory variation of antibiograms of methicillin-resistant and methicillin-susceptible Staphylococcus aureus strains with conventional and commercial testing systems. J Clin Microbiol. 1983 Nov;18(5):1226–1236. doi: 10.1128/jcm.18.5.1226-1236.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Boyce J. M., Lytle L. S., Walsh D. A. Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems. J Clin Microbiol. 1984 Dec;20(6):1068–1075. doi: 10.1128/jcm.20.6.1068-1075.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Boyce J. M. Reevaluation of the ability of the standardized disk diffusion test to detect methicillin-resistant strains of Staphylococcus aureus. J Clin Microbiol. 1984 Jun;19(6):813–817. doi: 10.1128/jcm.19.6.813-817.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fleming D. W., Helgerson S. D., Mallery B. L., Foster L. R., White M. C. Methicillin-resistant Staphylococcus aureus: how reliable is laboratory reporting? Infect Control. 1986 Mar;7(3):164–167. doi: 10.1017/s0195941700064006. [DOI] [PubMed] [Google Scholar]
- Hansen S. L., Freedy P. K. Variation in the abilities of automated, commercial, and reference methods to detect methicillin-resistant (heteroresistant) Staphylococcus aureus. J Clin Microbiol. 1984 Sep;20(3):494–499. doi: 10.1128/jcm.20.3.494-499.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lally R. T., Ederer M. N., Woolfrey B. F. Evaluation of the newly modified AutoMicrobic system gram-positive susceptibility-MIC card for detection of methicillin-resistant Staphylococcus aureus. J Clin Microbiol. 1986 Feb;23(2):387–387. doi: 10.1128/jcm.23.2.387-.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McDougal L. K., Thornsberry C. New recommendations for disk diffusion antimicrobial susceptibility tests for methicillin-resistant (heteroresistant) staphylococci. J Clin Microbiol. 1984 Apr;19(4):482–488. doi: 10.1128/jcm.19.4.482-488.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McDougal L. K., Thornsberry C. The role of beta-lactamase in staphylococcal resistance to penicillinase-resistant penicillins and cephalosporins. J Clin Microbiol. 1986 May;23(5):832–839. doi: 10.1128/jcm.23.5.832-839.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Peacock J. E., Jr Methicillin-susceptible "methicillin-resistant Staphylococcus aureus": a sheep in wolves' clothing. Infect Control. 1986 Mar;7(3):161–163. doi: 10.1017/s0195941700063992. [DOI] [PubMed] [Google Scholar]
- Stotler R. W., Meyer M. C. Detection of oxacillin-resistant staphylococci by the AutoMicrobic system. J Clin Microbiol. 1983 Nov;18(5):1205–1211. doi: 10.1128/jcm.18.5.1205-1211.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thornsberry C., McDougal L. K. Successful use of broth microdilution in susceptibility tests for methicillin-resistant (heteroresistant) staphylococci. J Clin Microbiol. 1983 Nov;18(5):1084–1091. doi: 10.1128/jcm.18.5.1084-1091.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]