Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1987 Apr;25(4):619–623. doi: 10.1128/jcm.25.4.619-623.1987

Evaluation of the Bio-EnzaBead test for syphilis.

N P Moyer, J D Hudson, W J Hausler Jr
PMCID: PMC266046  PMID: 3553231

Abstract

The sensitivity and specificity of the Bio-EnzaBead test for syphilis and the fluorescent treponemal antibody-absorption (FTA-ABS) test were determined by examining 262 serum samples, including 202 serum samples from patients with confirmed syphilis in various stages. Overall correlation with patient history was 95.8% with both tests. False-negative Bio-EnzaBead tests occurred in 9 of 86 (10.5%) cases of late-latent syphilis (greater than 2 years) and in 1 of 38 (2.6%) cases for which the stage of disease could not be determined. False-negative FTA-ABS tests occurred in 5 of 86 (5.8%) cases of late-latent syphilis (greater than 2 years) and in 2 of 38 (5.3%) cases for which the stage of disease could not be determined. One false-positive test occurred with Bio-EnzaBead, and the cause could not be determined. The reproducibility of the Bio-EnzaBead test was excellent when spectrophotometric readings were calibrated against either air or substrate blanks. The Bio-EnzaBead test for syphilis is a suitable alternative to the FTA-ABS test.

Full text

PDF

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Hunter E. F., Farshy C. E., Liska S. L., Cruce D. D., Crawford J. A., Feeley J. C. Sodium desoxycholate-extracted treponemal antigen in an enzyme-linked immunosorbent assay for syphilis. J Clin Microbiol. 1982 Sep;16(3):483–486. doi: 10.1128/jcm.16.3.483-486.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Pope V., Hunter E. F., Feeley J. C. Evaluation of the microenzyme-linked immunosorbent assay with Treponema pallidum antigen. J Clin Microbiol. 1982 Apr;15(4):630–634. doi: 10.1128/jcm.15.4.630-634.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Stevens R. W., Schmitt M. E. Evaluation of an enzyme-linked immunosorbent assay for treponemal antibody. J Clin Microbiol. 1985 Mar;21(3):399–402. doi: 10.1128/jcm.21.3.399-402.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Veldkamp J., Visser A. M. Application of the enzyme-linked immunosorbent assay (ELISA) in the serodiagnosis of syphilis. Br J Vener Dis. 1975 Aug;51(4):227–231. doi: 10.1136/sti.51.4.227. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES