Abstract
The API ZYM system was compared with four anaerobe identification systems for the definitive identification of Clostridium difficile by using 88 cultures of C. difficile grown on Mueller-Hinton blood agar medium. The API ZYM system yielded a distinct and consistent enzyme profile for all test strains, whereas the sensitivities of the other systems in identifying C. difficile ranged from 78 to 96% (AN-Ident, 77.9%; RapID-ANA, 88.6%; Minitek Anaerobe II, 90.9%; and API 20A, 95.5%). The API ZYM system is highly reliable in identifying C. difficile accurately, is rapid, and is relatively simple to use.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Al-Jumaili I. J., Bint A. J. Simple method for isolation and presumptive identification of Clostridium difficile. Zentralbl Bakteriol Mikrobiol Hyg A. 1981;250(1-2):142–146. [PubMed] [Google Scholar]
- Appelbaum P. C., Kaufmann C. S., Keifer J. C., Venbrux H. J. Comparison of three methods for anaerobe identification. J Clin Microbiol. 1983 Sep;18(3):614–621. doi: 10.1128/jcm.18.3.614-621.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bate G. Comparison of Minitek Anaerobe II, API An-Ident, and RapID ANA systems for identification of Clostridium difficile. Am J Clin Pathol. 1986 Jun;85(6):716–718. doi: 10.1093/ajcp/85.6.716. [DOI] [PubMed] [Google Scholar]
- Burlage R. S., Ellner P. D. Comparison of the PRAS II, AN-Ident, and RapID-ANA systems for identification of anaerobic bacteria. J Clin Microbiol. 1985 Jul;22(1):32–35. doi: 10.1128/jcm.22.1.32-35.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gresser M. E., Shanholtzer C. J., Gerding D. N., Garrett C. R., Peterson L. R. Evaluation of the 24-h API 20A anaerobe system for identification of Clostridium difficile. J Clin Microbiol. 1984 Jun;19(6):915–916. doi: 10.1128/jcm.19.6.915-916.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hofstad T. Evaluation of the API ZYM system for identification of Bacteroides and Fusobacterium species. Med Microbiol Immunol. 1980;168(3):173–177. doi: 10.1007/BF02122851. [DOI] [PubMed] [Google Scholar]
- Karachewski N. O., Busch E. L., Wells C. L. Comparison of PRAS II, RapID ANA, and API 20A systems for identification of anaerobic bacteria. J Clin Microbiol. 1985 Jan;21(1):122–126. doi: 10.1128/jcm.21.1.122-126.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Laughon B. E., Syed S. A., Loesche W. J. API ZYM system for identification of Bacteroides spp., Capnocytophaga spp., and spirochetes of oral origin. J Clin Microbiol. 1982 Jan;15(1):97–102. doi: 10.1128/jcm.15.1.97-102.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Levett P. N. Identification of Clostridium difficile using the API ZYM system. Eur J Clin Microbiol. 1985 Oct;4(5):505–507. doi: 10.1007/BF02014434. [DOI] [PubMed] [Google Scholar]
- Marler L., Allen S., Siders J. Rapid enzymatic characterization of clinically encountered anaerobic bacteria with the API ZYM system. Eur J Clin Microbiol. 1984 Aug;3(4):294–300. doi: 10.1007/BF01977476. [DOI] [PubMed] [Google Scholar]
- Murray P. R., Weber C. J., Niles A. C. Comparative evaluation of three identification systems for anaerobes. J Clin Microbiol. 1985 Jul;22(1):52–55. doi: 10.1128/jcm.22.1.52-55.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Muytjens H. L., van der Ros-van de Repe J., van Druten H. A. Enzymatic profiles of Enterobacter sakazakii and related species with special reference to the alpha-glucosidase reaction and reproducibility of the test system. J Clin Microbiol. 1984 Oct;20(4):684–686. doi: 10.1128/jcm.20.4.684-686.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Román M. C., Linares Sicilia M. J. Preliminary investigation of Candida albicans biovars. J Clin Microbiol. 1983 Aug;18(2):430–431. doi: 10.1128/jcm.18.2.430-431.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Slots J. Enzymatic characterization of some oral and nonoral gram-negative bacteria with the API ZYM system. J Clin Microbiol. 1981 Sep;14(3):288–294. doi: 10.1128/jcm.14.3.288-294.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tharagonnet D., Sisson P. R., Roxby C. M., Ingham H. R., Selkon J. B. The API ZYM system in the identification of Gram-negative anaerobes. J Clin Pathol. 1977 Jun;30(6):505–509. doi: 10.1136/jcp.30.6.505. [DOI] [PMC free article] [PubMed] [Google Scholar]