Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1988 Mar;26(3):573–575. doi: 10.1128/jcm.26.3.573-575.1988

Comparison of Track XI fluorometric immunoassay with Bio-EnzaBead enzyme-linked immunosorbent assay for detection of serum antibody to mouse hepatitis virus.

M C La Regina 1, J Lonigro 1, L Woods 1, W C Hall 1, R E Doyle 1
PMCID: PMC266335  PMID: 2833531

Abstract

The Track XI system (Microbiological Associates, Bethesda, Md.) was compared with the Bio-EnzaBead assay (Organon Teknika, Durham, N.C.) for the detection of antibody to mouse hepatitis virus (MHV). Strain A/J mice were inoculated intranasally with MHV type 3. Sera were collected at 1, 2, 4, and 9 weeks postinoculation and tested. Individual serum samples were retested twice by each method. The results suggested that the Track XI system was more sensitive and reliable than the Bio-EnzaBead assay in detecting antibody to MHV type 3 in individual serum samples from A/J mice.

Full text

PDF
573

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Barthold S. W., Smith A. L. Mouse hepatitis virus S in weanling Swiss mice following intranasal inoculation. Lab Anim Sci. 1983 Aug;33(4):355–360. [PubMed] [Google Scholar]
  2. Barthold S. W., Smith A. L. Mouse hepatitis virus strain--related patterns of tissue tropism in suckling mice. Arch Virol. 1984;81(1-2):103–112. doi: 10.1007/BF01309300. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Dupuy J. M., Levey-Leblond E., Le Prevost C. Immunopathology of mouse hepatitis virus type 3mii. effect of immunosuppression in resistant mice. J Immunol. 1975 Jan;114(1 Pt 1):226–230. [PubMed] [Google Scholar]
  4. Hall S. M., Confer A. W. Comparison of TRACK XI fluorometric immunoassay system with other serologic tests for detection of serum antibody to Brucella abortus in cattle. J Clin Microbiol. 1987 Feb;25(2):350–354. doi: 10.1128/jcm.25.2.350-354.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Hsu S. M., Raine L., Fanger H. A comparative study of the peroxidase-antiperoxidase method and an avidin-biotin complex method for studying polypeptide hormones with radioimmunoassay antibodies. Am J Clin Pathol. 1981 May;75(5):734–738. doi: 10.1093/ajcp/75.5.734. [DOI] [PubMed] [Google Scholar]
  6. Le Prevost C., Levy-Leblond E., Virelizier J. L., Dupuy J. M. Immunopathology of mouse hepatitis virus type 3 infection. Role of humoral and cell-mediated immunity in resistance mechanisms. J Immunol. 1975 Jan;114(1 Pt 1):221–225. [PubMed] [Google Scholar]
  7. Prévost C. L., Virelizier J. L., Dupuy J. M. Immunopathology of mouse hepatitis virus type 3 infection. III. Clinical and virologic observation of a persistent viral infection. J Immunol. 1975 Sep;115(3):640–643. [PubMed] [Google Scholar]
  8. Smith A. L. An immunofluorescence test for detection of serum antibody to rodent coronaviruses. Lab Anim Sci. 1983 Apr;33(2):157–160. [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES