TABLE 6.

Microhardness of trabecular and cortical bone in vertebral bodies (VB), and of cortical bone in distal femurs in each treatment group.

Fluoride Treatment (ppm) Strain A/J Strain SWR/J Strain 129P3/J

VB microhardness for trabecular bone 0 27.6 ± 2.1 25.1 ± 2.5 25.9 ± 1.7

100 24.5 ± 2.4 24.8 ± 3.2 25.6 ± 1.7

VB microhardness for cortical bone 0 31.1 ± 2.0 30.3 ± 0.9 31.7 ±1.7

100 31.4 ± 3.1 30.6 ± 1.6 31.4 ± 1.3

Distal femur cortex microhardness 0 39.4 ± 1.5 36.8 ± 2.3 37.9 ± 2.6

100 38.0 ± 2.5 35.3 ± 1.0 37.5 ± 1.7

Data are presented as means ± SD. No statistical difference was noted for the microhardness of cortical and trabecular bone in the three strains.